Page 1
ORIGINAL INSTRUCTION > EN Gasoline Generator Instruction Manual Model: RAC3100-FR BUILDER SAS 32, rue Aristide Bergès - ZI 31270 Cugnaux - France Warning: Please read the manual carefully before using the unit!
1. SAFETY INSTRUCTION Warning: 1. Attention! Exhaust gases are toxic. Do not operate the generator in a room without ventilation system! 2. Children should be protected by keeping them at a safe distance from the generator set! 3. Refilling of the generating sets are not allowed during the operation! 4.
Page 4
Run the generator in respect of the power indicated in the user’s manual. Do not run the generator with an overload or at excessive speed. The silencer of the generator becomes extremely hot when the motor runs or even for a time after it has ...
Page 5
Fuel is combustible and easily ignited. Do not refuel during operation. Do not refuel while smoking or near naked flames. Do not spill fuel. Some parts of the internal combustion engine are hot and may cause burns. Pay attention to the warnings on the generating set.
Page 6
Keep the fuel in an appropriate recipient and sheltered from any sources of fire. Carry out filling in a safe place, and slowly open the fuel cap to release the pressure which has built up inside the tank. Wipe up any drops of petrol that have spilled before starting the motor. To prevent fire, move the generator at least 4 metres away from the area for filling with fuel.
Page 7
There may be damage if the device connected is not designed to function with a voltage tolerance of +/- 10% or a frequency tolerance of +/- 3 % compared with those of the generator. Protection of the environment You must periodically check the silencer (Before doing this, switch off the generator and let it cool ...
Page 8
Carbon monoxide (CO)danger Fire hazard Risk of being burnt Read carefully these labels, they are also in the product...
3. CONTROLS 1) Engine Switch To start and stop the engine. Switch position: OFF: To Stop the engine. ON: To run the engine after starting. 2) Recoil Starter To start the engine, pull the starter grip lightly until resistance is felt, then pull briskly. NOTICE Do not allow the starter to snap back against the engine.
Page 11
4) Choke The choke is used to provide an enriched fuel mixture when starting a cold engine. It can be opened and closed by operating the choke lever or choke rod manually. Move the lever or the rod to the CLOSE position to enrich the mixture. 5) Circuit Breaker The circuit breaker will automatically switch OFF if there is a short circuit or a significant overload of the generator at the receptacle.
4. GENERATOR USE 1) Connections to a Building’s Electrical System Connections for standby power to a building's electrical system must be made by a qualified electrician. The connection must isolate the generator power from utility power, and must comply with all applicable laws and electrical codes. WARNING Improper connections to a building's electrical system, can allow electrical current from the generator to feedback into the utility lines.
Page 13
3) AC Applications Before connecting an appliance or power cord to the generator: • Make sure that it is in good working order. Faulty appliances or power cords can create a potential for electrical shock. • If an appliance begins to operate abnormally, becomes sluggish or stops suddenly, turn it off immediately.
Even with suitable carburetor jetting, engine horsepower will decrease approximately 3.5% for each 1000 foot (300 meter) increase in altitude. The effect of altitude on horsepower will be greater than this if no carburetor modification is made. NOTICE If a engine jetted for high altitude is used at a lower altitude, the lean air fuel mixture will reduce performance and may over-heat and seriously damage the engine.
Page 15
2) Fuel Recommendation 1. Check the fuel level gauge. 2. Refill the tank if the fuel level is low. Do not fill above the shoulder of the fuel strainer. WARNING • Gasoline is extremely flammable and is explosive under certain conditions. •...
NOTICE Running the engine with persistent spark knock or pinging can cause engine damage. Running the engine with persistent spark knock or pinging is misuse, and the Distributor's Limited Warranty does not cover parts damaged by misuse. Oxygenated Fuels Some gasoline are blended with alcohol or an ether compound to increase the octane. These gasoline are collectively referred to as oxygenated fuels.
Page 17
Starting the engine 1. Make sure that the AC circuit breaker is in the OFF position. The generator may be hard to start if a load is connected. 2. Turn the fuel valve to the ON position. 3. Turn the choke lever or to the CLOSE position, or pull the choke rod out to the CLOSE position. 4.
7. MAINTENANCE Good maintenance is essential for safe, economical, and trouble-free operation. It will also help reduce air pollution. WARNING Exhaust gas contains poisonous carbon modoxide. Shut off the engine before performing any maintenance. If the engine must be run, make sure the area is well ventilated. Periodic maintenance and adjustment is necessary to keep the generator in good operating condition.
Page 19
unusually wet or dusty conditions, consult your servicing dealer for recommendations applicable to your individual needs and use. 2) Tool kit The tools supplied with the generator will help you to perform the owner maintenance procedures listed on the following page. Always keep this tool kit with the generator. NOTE: Diagrams may vary according to the types.
Page 20
Please dispose of used motor oil in a manner that is compatible with the environment We suggest you take it in a sealed container to your local service station or recycling center for reclamation. Do not throw it in the trash or pour it on the ground. 4) Air cleaner service A dirty air cleaner will restrict air flow to the carburetor.
Page 21
5) Spark Plug Service Recommended spark plugs: F5T or F6TC or F7TJC or other equivalents To ensure proper engine operation, the spark plug must be properly gapped and free of deposits. If the engine has been running, the muffler will be very hot. Be careful not to touch the muffler. 1) Remove the spark plug cap.
NOTICE The spark plug must be securely tightened. An improperly tightened spark plug can become very hot and could damage the engine. Never use spark plugs which have an improper heat range. Use only the recommended spark plugs or equivalent. 8.
Page 23
WARNING Gasoline is extremely flammable and is explosive under certain conditions. Perform this task in a well ventilated area with the engine stopped. Do not smoke or allow flames or sparks in the area during this procedure. The fuel of this machine is combustible and deflagrating. After the machine has been shut down, the additional fuel must be treated properly and the local environmental requirements must be met.
9. TROUBLESHOOTING When the engine will not start: Is there fuel in the tank? Refill the fuel tank Is there oil in the tank? Add the recommended oil. STILL SPARK Is there spark from Replace the Take the generator to an spark plug.
Page 25
No electricity at the AC receptacles Is the AC circuit breaker ON Turn the AC circuit breaker ON NO DEFECTS Check the electrical appliance or Take the generator to an equipment for any defects. authorized generator dealer. Replace the electrical appliance DEFECTS or equipment.
11. SPECIFICATIONS Engine Engine model RAC3100-FR Engine type Single cylinder, 4-strokes, Forced air cooling, OHV. Displacement( CC) 212cc Rated speed 3000/min Igniting system Transistor magneto Starting system Recoil Fuel Volume (L) 15 L Continuous operation time (h) 10.5 h Min. Fuel consumption (g/kW.h) 360 g/kW.h...
BUILDER SAS ZI, 32 RUE ARISTIDE BERGES – 312070 CUGNAUX – FRANCE Declares that the machinery designated below: Gasoline Generator RAC3100-FR Model: Serial number: 20201003315-20201003669 Complies with the provisions of the Directive “machinery” 2006/42/CE and national laws transposing it: Also complies with the following European directives:...
13. WARRANTY WARRANTY The manufacturer guarantees the product against defects in material and workmanship for a period of 2 years from the date of the original purchase. The warranty only applies if the product is for household use. The warranty does not cover breakdowns due to normal wear and tear. The manufacturer agrees to replace parts identified as defective by the designated distributor.
14. PRODUCT FAILURE WHAT TO DO IF MY MACHINE BREAKS DOWN? If you bought your product in a store: a) Empty the fuel tank. b) Make sure that your machine is complete with all accessories supplied, and clean! If this is not the case, the repairer will refuse the machine.
15. WARRANTY EXCLUSIONS THE WARRANTY DOES NOT COVER: • Start-up and setting up of the product. • Damage resulting from normal wear and tear of the product. • Damage resulting from improper use of the product. • Damage resulting from assembly or start-up not in accordance with the user manual. •...
Need help?
Do you have a question about the RAC3100-FR and is the answer not in the manual?
Questions and answers