emcom IP6030 Series Installation, Operation, And Programming Manual

Rugged, handset voip phones

Advertisement

Quick Links

(609) 585-5500
92 N. Main Street, Building 18A
Fax: (609) 585-7723
Windsor, NJ 08561
info@emcomsys.com
www.emcomsys.com
IP6030 Family
Rugged, Handset VoIP Phones
Installation, Operation and Programming
V3
June 03, 2021

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IP6030 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for emcom IP6030 Series

  • Page 1 (609) 585-5500 92 N. Main Street, Building 18A Fax: (609) 585-7723 Windsor, NJ 08561 info@emcomsys.com www.emcomsys.com IP6030 Family Rugged, Handset VoIP Phones Installation, Operation and Programming June 03, 2021...
  • Page 2 RECORD OF CHANGES Changes to this IP6030 Family Rugged, Handset VoIP Phones I&O and Programming V3 shall be recorded in the accompanying table. Record of Changes Table Rev # Date Brief Description Change Order # 1/26/2018 Correcting Mounting & Connection Diagram for IP6030 (Page 15 of 15) 4/2/2018 Para.
  • Page 3: Product Description

    The EmVista Central call management and conferencing system Programming of the phone is accomplished through a simple web browser interface or through Emcom Systems’ Emvista Maintenance Station application, which is typically used for large installations. The IP6030 family utilizes DSP (Digital Signal Processing) to manage audio levels. The audio levels are remotely programmable and the handset contains a press bar to set 3 levels of earpiece volume.
  • Page 4: Ethernet Connections

    A bezel is available to hide the rough-in of in-wall mounting. Emcom Systems can provide the bezel and both in-wall and surface mount enclosures. It is recommended that where possible, all access to enclosures be from the bottom.
  • Page 5: Diagnostic Connector

    2.2.1.4 Diagnostic Connector J17 – This 8-pin connector allows a serial port connection and is normally used for factory trouble- shooting. This connector is labeled SERIAL on the case of the unit. 2.2.1.5 External Trigger J26 – This connector provides for an external means of activating the unit and is used for special circumstances.
  • Page 6: Operating Temperature Range

    4 ohms or higher. 2.2.2.3 Beacon Connection to an Emcom Systems blue, high intensity, LED beacon is provided at the connector labeled BEACON. This output provides a constant current to ensure LED long life. Operating Temperature Range The operating temperature range of the IP6030 family is from -30 C to +55 C (-22 F to 131 F).
  • Page 7: Display Option

    3.3 Additional IP6030 functionality 3.3.1 Speaker Beacon Option With a speaker beacon board included in the unit, the ability to add an external high power speaker and a high intensity blue beacon is enabled. The board provides up to 20 watts of audio power to an external 4 ohm speaker and provides a current source with flashing capability for the beacon.
  • Page 8 As shipped from the factory, the IP address of the unit is 192.168.1.22X where X is equal to the last digit of the serial number of the unit. The serial number is on the back case of the unit. Example: Serial number is 653 IP address is 192.168.1 223 Upon pressing enter, the login page will appear.
  • Page 9: Changing The Phonebook

    4.1.2 Changing the IP Address, Subnet Mask and Default Gateway Using the left pane navigator, click on WAN. The navigation tree will expand and three selection buttons will appear in the right pane. Make sure that the Static IP Address button is selected. In the navigation tree, click on Static IP Settings.
  • Page 10 The phonebook consists of a list of entries that are created by filling in the fields of the above table. Each phonebook entry maps an input condition (Pattern), such as a number dialed on the IP6030’s keypad, to a target destination called a SIP-URI which is presented to the target as User Name @ Caller Address/Telephone Num.
  • Page 11 match the first. The length of the dialed string must match the length of the pattern. If the phonebook contains “????” and “9???????????”, then any number beginning with “9” must have eleven additional digits, but any number beginning with a digit other than nine will initiate a call after three more digits are dialed.
  • Page 12 4.1.4 Changing the Acoustic Environment and Audio Levels The acoustic environment and audio level settings are also reached as a subdirectory of the VoIP Line Settings menu. Click on VoIP Line Settings and then click on Phone Settings. The following screen will appear: Auto Answer –...
  • Page 13 Voice Volume - Voice volume sets the level heard from the IP6030 speaker (if a speaker is attached and it is being used in a paging mode). The adjustment levels are from 0 to 7 with 7 the loudest. The numbers on this screen may be changed when the phone is in idle mode. The next page will reflect the new level.
  • Page 14 4.1.6 Additional Programmable Functions A number of additional programmable functions are available through the various submenus of the left navigation pane. These functions are typically used only for unique applications. It is recommended that the user first communicate with factory support before any setup changes in these areas are attempted.
  • Page 15 947214 Rev. F Page 15 of 15 03 June 21 IP6030 Family Rugged, Handset VoIP Phones Installation, Operation and Programming V3...