JB-100D KYOWA Lightning Arrester Kit
Thank you for purchasing the KYOWA Lightning Arrester Kit.
Before using it, read this operation manual carefully, in order to
Also, keep the manual within easy reach
ensure correct usage.
so that you can refer to it whenever necessary.
When using this instrument, be sure to observe the following safety
precautions. KYOWA Electronic Instruments Co.,Ltd. Will not be
liable for any damage caused by usage against these precautions.
Please check our website for the latest information.
1. Calling the operator's attention
The following cautionary symbols and headlines are used to i
nvite the operator's attention. Be sure to observe the accompa
rying precautions in order to safeguard the operator and prese
rve the performance of the instrument.
Improper handling may cause serious injury to
Warning!
the operator. To avoid it, be sure to observe the
accompanying instructions.
Improper handling may cause deleterions ef-
Caution!
fects to the operator's body. To avoid it, be sure
to observe the accompanying instructions.
In order to avoid the instrument's failure and
Notes
malfunction, be sure to observe the accompa-
nying instructions.
2. Safety precautions
Warning!
Keep the resin out of the mouth, or injury to death can occur. If
swallowed, vomit it by immediately having a plenty of water,
then see a physician.
Keep the resin out of the eye, or serious damage can occur to
the eye. If the resin gets in the eye, immediately wash it off with
water, then see an eye doctor. Use glasses or other eye protector.
While handing the resin, maintain proper ventilation, or poi-
soning can occur.
Avoid handling the resin nearby fire, or it can take fire.
Caution!
Avoid skin contact with the resin, or a rash can gloves or othe
protector.
Keep the resin out of children's reach.
Mark on
Conductor
junction
color
board
Red
R
White
W
Black
B
Green
G
Shield
S
Taflex
※ Length from the cut end of cable sheath to that of Taflex
OPERATION MANUAL
Table 1. Cable end treatment
Shielded chloropren cable
Taflex cable
0.5×4-conductor
0.5×4-conductor
(replete type)
23
33
18
28
33
(Tube:25)
3. Configuration of the Kit
This kit consists of following parts. When unpacking, make sure that
all these are included.
● Mold case consisting of upper and lower units ............1 set.
● Mold case injection port cover .............................. 1 pc.
● Resin (Unipack epoxy resin No.4, size B) ..................1 bag.
● Sandpaper ...................................................... 1 sheet.
● Adhesive tape (№23) .......................................... 5 sheet.
● Junction board (JB-100D) .................................... 1 pc.
● Spacer tape (P3,0.6m)....................................... 1 sheet.
● Bundle strap (Tylap TY-24M ) .................................4 pcs.
●
External case connection cable (Plain meshed copper wire, 3m)
● Ground wire fixing screw (M4×5 stainless steel) ............ 1 pc
● Operation manual(this book) ................................. 1 copy.
● Wipe off the resin thoroughly form the tools in use before
it hardens.
4. Tools and meterials requried for cable connection.
Which are not included in the kit
■Tools
● Heavy-duty nippers ● Pliers or pinchers ●drill
● Hacksaw (heavy-duty nippers may be used) ● Soldering iron (30
to 60Wor so)
■Materials
● Insulation tape (19mm wide vinyl tape)
● φ3mm Ilux tube (for the shield wire only)
■Others
● Piece of cloth ● Rubber gloves ● Wor gloves ●Protective
glasses
5. Cable preteratment
5.1
Peel the cable sheaths from the conductors and cut
each conductor to the length described in the table.
Cable type
Chloroprene
0.75×4-conductor
23
23
33
33
23
23
33
33
Not used
Not used
※ 170
IM-A-1337 2020.9
... 1 pc.
Notes
● Toluene ● Solder
Cable attached to
Cable attached to
KYOWA trans-
Carison meter
ducer
38
33
23
23
38
33
23
23
Not used
Not used