Thank you for purchasing a PRO2 check Elite® Multifunction Concentrator Indicator. By
using this single, easy to operate device a home care provider can quickly and accurately
perform all of the most common field tests required to service oxygen concentrators:
• Measurement of the concentration of oxygen delivered from the concentrator
• Verification of accuracy of the concentrator's built-in flow control with in the tolerance
of the measuring device and altitude adjustment if needed.
• Ensuring that the unit is operating within manufacturer's output pressure specifications
When used to measure the concentration of oxygen being produced, the device utilizes
technology already used in many oxygen concentrators to trigger "Low O2" alarms -
ultrasound. By combining this proven sensor technology with built-in pressure and flow
measurement instruments, Salter Labs® has produced in a single unit a simple, conve-
nient, and more cost effective product to check the major output parameters of oxygen
concentrators. The indicator when operating in the oxygen concentration measurement
mode responds faster, has no fuel cell to replace, and is simpler to use than a fuel cell ana-
lyzer. The flow and pressure measuring functions of the unit allow the provider to quickly
and easily measure these outputs without changing equipment.
1.
Remove the PRO2 check Elite® Multifunction Concentrator Indicator from the
package. Make sure you have the following items:
• PRO2 check Elite® indicator unit
• 9-volt battery (factory installed)
• 2 foot connecting tubing
• Carrying case and strap
• Operation Manual
2.
The PRO2 check Elite® was calibrated at the factory. However, the
proper calibration of the unit's oxygen concentration measurement mode
can be quickly and easily verified by following the "Pure Oxygen Verifi-
cation" procedure on page 7 of this manual
If accreditation organizations or internal policies and procedures require rou-
3.
tine calibration, instructions on performing both a "Quick One Step Calibra-
tion Procedure" to USP oxygen can be found on page 7 of this manual. A "Full
Two Step Calibration Procedure" to both USP oxygen and room air can be
found on page 8 of this manual. Instructions on calibrating the pressure and
flow measurement functions of this device are found of page 9 of this manual.