3. Fan control

Tr: Room temperature
Ts: Setting temperature

3-1. Indoor fan control

¢ Fan speed
Indoor fan speed is defined as below.
Operation mode
Heating
Cooling
Fan
Dry
¢ Fan operation
Airflow can be switched in 5 steps such as AUTO, QUIET, LOW, MED, HIGH while indoor unit fan
only runs.
When fan mode is set at AUTO, it operates on MED fan speed.
¢ Cooling operation
Switch the airflow AUTO, and indoor fan motor will run according to room temperature, as below.
On the other hand, if switched in HIGH—QUIET, indoor motor will run at a constant airflow of COOL
operation modes QUIET, LOW, MED, HIGH as shown in "Fan speed" above.
Airflow change over (Cooling: Auto)
2°C
¢ Dry operation
During dry operation, fan speed setting can not be changed as shown in "Fan speed" above.
3-1. Indoor fan control
Fan mode
ARXG30KMLA
HIGH
MED
LOW
QUIET
S-LOW
HIGH
MED
LOW
QUIET
S-LOW
HIGH
MED
LOW
QUIET
Soft quiet
Tr - Ts ≥
2°C
> Tr - Ts ≥
1°C
1°C > Tr - Ts
When room
temperature drops
Speed (rpm)
ARXG36KMLA
1,270
980
790
630
420
1,130
980
790
630
420
1,270
980
790
630
420
X zone: 630
X zone: 630
J zone: 630
J zone: 630
Tr - Ts ≥
HIGH mode
2.5°C
MED mode
1.5°C > Tr - Ts
LOW mode
When room
temperature rises
- (01-12) -
ARXG45KMLA
1,270
1,300
980
1,020
790
840
630
670
420
420
1,130
1,310
980
1,020
790
840
630
670
420
420
1,270
1,310
980
1,020
790
840
630
670
420
420
X zone: 670
J zone: 670
2.5°C
> Tr - Ts ≥
1.5°C