TE Connectivity SRS2M-2NO Installation, Use And Maintenance Manual

Safety relay muting module

Advertisement

Quick Links

SRS2M-2NO SAFETY RELAY MUTING
MODULE
Installation, use and maintenance guide

Advertisement

Table of Contents
loading

Summary of Contents for TE Connectivity SRS2M-2NO

  • Page 1: Srs2M-2No Safety Relay Muting Module

    SRS2M-2NO SAFETY RELAY MUTING MODULE Installation, use and maintenance guide...
  • Page 2: Table Of Contents

    CONNECTION OF EXTERNAL CONTACTORS K1 AND K2 ............. 7 CONNECTON EXAMPLES ......................9 CONNECTION OF SRS2M-2NO WITH 2 PAIRS OF PHOTOCELLS (WITH K1-K2 EXTERNAL CONTACTORS) 9 CONNECTION OF SRS2M-2NO WITH 1 PAIR OF PHOTOCELLS (WITH K1-K2 EXTERNAL CONTACTORS) 10 SERIES CONNECTION OF SRS2M-2NO WITH 2 PAIRS OF PHOTOCELLS (WITH K1-K2 EXTERNAL CONTACTORS) ..............................
  • Page 3: Overview

    • mode.  For safe use of the SRS2M-2NO module, it is essential to read and understand the contents of this handbook.  Failure to comply with the prescriptions indicated in this handbook may result in very high risks for the operating personnel of the machine protected.
  • Page 4: New Safety Parameters For Type 2 Barriers And Mandatory Labelling

    SRS2M-2NO SAFETY RELAY MUTING MODULE NEW SAFETY PARAMETERS FOR TYPE 2 BARRIERS AND MANDATORY LABELLING  With the publication of Edition 3 of the harmonized EN 61496-1 standard it is no longer possible to use a Type 2 safety light barrier for safety functions assessed as SIL 2 / PL d.
  • Page 5: Operating Modes Description

    SRS2M-2NO SAFETY RELAY MUTING MODULE OPERATING MODES DESCRIPTION OPERATING MODES SELECTION TERMINAL 6 TERMINAL 15 OPERATION 0 VDC +24 VDC Automatic +24 VDC 0 VDC Manual 0 VDC 0 VDC Non-permissible conditions +24 VDC +24 VDC Table 1 AUTOMATIC MODE...
  • Page 6: Manual Mode

    SRS2M-2NO SAFETY RELAY MUTING MODULE MANUAL MODE In this operating mode, the outputs of the safety relay are activated only if the protected area is free and after sending the RESTART signal to the unit using the push-button or by means of a specific command on the RESTART input (terminal 4).
  • Page 7: Connection Of External Contactors K1 And K2

    SRS2M-2NO SAFETY RELAY MUTING MODULE CONNECTION OF EXTERNAL CONTACTORS K1 AND K2 Control of external contactors K1 K2 can be activated in both operating modes. If this control must be used, the series of normally closed contacts of the external contactors must be connected to terminal 20 of the safety relay module (Figure 3 and Figure 4).
  • Page 8 SRS2M-2NO SAFETY RELAY MUTING MODULE Figure 4 – Manual operation with K1 K2 relays INDUSTRIAL/SRS2-2NO SAFETY RELAY MODULE...
  • Page 9: Connecton Examples

    SRS2M-2NO SAFETY RELAY MUTING MODULE CONNECTON EXAMPLES Connection of SRS2M-2NO with 2 pairs of photocells (with K1-K2 external contactors) Figure 5 INDUSTRIAL/SRS2M-2NO SAFETY RELAY MUTING MODULE...
  • Page 10: Connection Of Srs2M-2No With 1 Pair Of Photocells (With K1-K2 External Contactors)

    SRS2M-2NO SAFETY RELAY MUTING MODULE Connection of SRS2M-2NO with 1 pair of photocells (with K1-K2 external contactors) Figure 6 INDUSTRIAL/SRS2-2NO SAFETY RELAY MODULE...
  • Page 11: Series Connection Of Srs2M-2No With 2 Pairs Of Photocells

    SRS2M-2NO SAFETY RELAY MUTING MODULE Series connection of SRS2M-2NO with 2 pairs of photocells (with K1-K2 external contactors) Figure 7  In this case, the 2 photocells are connected in series and the module INPUT2 (terminal 18) is not utilized; this signal must be connected to the TEST2 (terminal 19).
  • Page 12: Connection Of Srs2M-2No With 4 Pairs Of Photocells (Without K1-K2 External Contactors)

    SRS2M-2NO SAFETY RELAY MUTING MODULE Connection of SRS2M-2NO with 4 pairs of photocells (without K1-K2 external contactors) Figure 8 INDUSTRIAL/SRS2-2NO SAFETY RELAY MODULE...
  • Page 13: Muting Function

    Control of the dangerous opening can be de-activated only by a correct sequence of interruption of the beams of the muting sensors. Figure 9 - Muting with SRS2M-2NO on palletizing system application example MUTING SEQUENCE The timing diagrams in Figure 10 and Figure 11 show the correct signal sequence.
  • Page 14 SRS2M-2NO SAFETY RELAY MUTING MODULE  The muting enable command will only enable the muting function and should be generated at the appropriate time by the machine control system(e.g., when the muting function is needed); it has no effect on the deactivation of the muting function.
  • Page 15: Muting Override Function

    Therefore, all operations must be carried out under the strict supervision of expert personnel.  During the installation of the SRS2M-2NO safety relay module be sure to avoid short circuits between the contacts 7 and 8. The operator will use the override mode previously selected: 1.
  • Page 16: Override With Pulse Control

    SRS2M-2NO SAFETY RELAY MUTING MODULE OVERRIDE WITH PULSE CONTROL This function is activated inverting (maximum delay = 400ms) the condition of pin 7 and 8 of the receiver using for example a push button (switch). During the override, the 7 and 8 are not controlled.
  • Page 17: Electrical Connections

    Terminal tightening torque: 5 to 7lb-in (0,6 to 0,7 Nm). Figure 12  Install the SRS2M-2NO safety relay module in an environment with a protection rating of at least IP54.  If more modules SRS2M-2NO must be installed in the same board panel, to avoid overheating, maintain between them one minimal distance of 2cm.
  • Page 18: Pinout

    SRS2M-2NO SAFETY RELAY MUTING MODULE PINOUT TERMINAL SIGNAL TYPE OF DESCRIPTION NUMBER NAME SIGNAL Input Muting Sensor n°1 SENSOR 1 Input Muting Sensor n°2 SENSOR 2 Input Power supply 24VDC 24VDC TIMEOUT1 Input Timeout selection n°1 * Input Timeout selection n°2 *...
  • Page 19: Checklist After Installation

    7. Operate a complete System Test. Table 5  The System Test is mandatory because a type 2 device is connected upstream to SRS2M-2NO safety module (e.g., photocell, safety photocell, etc). Refer to "THE SYS TEST COMMAND INPUT" INDUSTRIAL/SRS2M-2NO SAFETY RELAY MUTING MODULE...
  • Page 20: Input And Output

    The SYS TEST command (terminal 16) must be forwarded to the safety module connecting the terminal 16 to the +24VDC. The SYS TEST command must be sent to SRS2M-2NO connecting terminal 16 to the 24VDC for a time t>40 msec and remains operative as long as the terminal 16 is connected to 24VDC.
  • Page 21: The Muting Enable Input

    Muting status must be highlighted to the outside using an indicator light close to the guarded opening.  SRS2M-2NO is equipped with a “MUTING LAMP” output (terminal 10) to which the indicator light can be connected and is able to monitor its correct operation and that it is present.
  • Page 22: Use Of K1 And K2 Auxiliary Contact Elements

    SRS2M-2NO SAFETY RELAY MUTING MODULE USE OF K1 AND K2 AUXILIARY CONTACT ELEMENTS For loads with higher voltage and current characteristics than those indicated in the table above, use of auxiliary external relays or contactors suitable for the load to be controlled is recommended.
  • Page 23: Status Indicators / Fault Diagnosis

    SRS2M-2NO SAFETY RELAY MUTING MODULE STATUS INDICATORS / FAULT DIAGNOSIS NORMAL OPERATION STATUS INDICATORS WITH 1 PHOTOCELL CONNECTED MEANING IN2/FAIL GUARD/BREAK GREEN RED/GREEN RED/GREEN GREEN Power up test Photocell interrupted Output relays opened Photocell free GREEN YELLOW Output relays opened...
  • Page 24: Fault Diagnosis

    SRS2M-2NO SAFETY RELAY MUTING MODULE FAULT DIAGNOSIS NORMAL OPERATION GUARD/BREAK MEANING FAIL RED/GREEN (pulses red LED) GREEN Internal fault (2 pulses) Internal relays fault (3 pulses) K1 K2 external relays fault (4 pulses) User configuration failure (5 pulses) User configuration changed without system restart: ...
  • Page 25: Technical Data

    SRS2M-2NO SAFETY RELAY MUTING MODULE TECHNICAL DATA SAFETY DATA VALUE STANDARD Type 2 EN 61496-1: 2020 SIL 1 EN 61508:2010 Safety level SILCL 1 EN 62061:2005 / A2:2015 Cat.2 EN ISO 13849-1: 2015 Device lifetime Around 20 years EN ISO 13849-1: 2015 Certifications cULus, TÜV...
  • Page 26: Dimensions (Mm)

    SRS2M-2NO SAFETY RELAY MUTING MODULE CONNECTIONS / OPERATION Operating modes Manual or Automatic, selectable from terminal block Connections 24 Terminal block with protection against reversal of polarity Status indicators LED: Input - Output Status - Fail – Sensor - Muting Max.
  • Page 27: Indications And Information For Environmental Protection

    SRS2M-2NO SAFETY RELAY MUTING MODULE INDICATIONS AND INFORMATION FOR ENVIRONMENTAL PROTECTION Dispose of the product in an eco-compatible manner and in accordance with national legislation. For Countries in the European Union: Pursuant to the Directive no. 2012/19/EU on waste electrical and electronic equipment (WEEE).
  • Page 28 Manual © 2023 TE Connectivity. All Rights Reserved. TE, TE Connectivity, TE connectivity (logo), and EVERY CONNECTION COUNTS are trademarks owned or licensed by the TE TE Connectivity Connectivity Ltd. family of companies. Other product names, logos, and company names mentioned herein may be trademarks of their respective owners.

Table of Contents