General Information; Wiring A Plug - Zanussi GC5557 Instructions For The Use And Care

Table of Contents

Advertisement

General information
Dimensions
Overall height
900 mm
Overall width
550 mm
Overall depth
598 mm
Location
The appliance may be located in a
kitchen, a kitchen/diner or a bed-sitting
room but not in a room containing a bath
or shower.
The cooker should not be installed in a
room of volume less than 6 m3 (200 ft3)
or a bed-sitting room of volume less than
21 m3 (750 ft3).
When the appliance is in its normal
E
osition, the gap between the bottom
ont trim and the floor must be
unobstructed.
Position
The stops fitted to this appliance are
used to maintain a space of
approximately 12 mm (V
2
") at the rear.
When replacing after cleaning push the
cooker back to its stop and ensure that
the same distance is maintained at each
rear edge.
Shelves and wall cabinets must not be
fitted closer than 787 mm (31") to the top
of the hotplate. The appliance may be
flush fitted to adjacent cupboard units
below hotplate level but a 2 mm gap at
either side may be desirable to enable the
appliance to be moved for cleaning.
If either side of the cooker is next to a
wall, tall cupboard or base unit which is
taller than 906.5 mm (35.7"), a 114 mm
(
4
V
2
") space must be left between the
cooker and the wall, tall cupboard or
base unit to prevent heat damage.
Wiring a plug (Fig. u
Warning:
THIS APPLIANCE MUST BE EARTHED.
DO NOT EARTH THIS APPLIANCE TO
THE GAS SUPPLY PIPING.
This appliance must be connected to
220V - 240V A.C. 50 Hz supply which
incorporates a 3 ampere fuse, if a
13 ampere plug is used. If any other type
of plug is used it should incorporate a
5 ampere fuse in either the plug or
adaptor or at the distribution board. The
appliance is supplied with 2 metres (6 ft)
of 5 amp 3 core cable, fitted with a non-
rewireable plug. If this plug is unsuitable
for your socket then the plug should be
cut off and an appropriate plug fitted.
The removed plug should be disposed of
as insertion or the plug into a 13 amp
socket is likely to cause an electrical
hazard.
Fig. 1
If the length of cable is insufficient to
allow the appliance to be plugged into
the nearest supply socket, the supply
cable can be either:
(i) Replaced totally by a longer cable at
least 0.75 mm2 nominal cross sectional
area (24/0.2 mm).