Download Print this page
MG M6NBS Instruction Manual
MG M6NBS Instruction Manual

MG M6NBS Instruction Manual

Installation base

Advertisement

Quick Links

INSTRUCTION MANUAL
INSTALLATION BASE
BEFORE USE ....
Thank you for choosing us. Before use, please check con-
tents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact our sales office or representatives.
■ PACKAGE INCLUDES:
Installation base ..................................................................(1)
■ MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■ INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■ CONFORMITY WITH EU DIRECTIVES OR UL
• The equipment must be mounted inside a panel.
• The actual installation environments such as panel con-
figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure the CE conform-
ity.
■ GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply for safety.
■ ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -20 to +55°C
(-4 to +131°F) with relative humidity within 30 to 90%
RH in order to ensure adequate life span and operation.
• Keep space of at less 1 cm (0.4 inches) on the left side of
the power supply module (model: M6-PSM).
■ WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
MODEL
COMPONENT IDENTIFICATION
■ FRONT VIEW
• M6NBS-08, M6NBS-08P
Signal Conditioner or
Power Supply Module
1 2
• • • • • •
• M6NBS-08A
Power Supply
Conditioner
Module
1 2
Install signal conditioners from the slot at either end.
Power Supply Modules (M6NPS1 or M6NPS2) could be
mounted at any slots, however, installing them at either end
is generally recommended.
Power Supply Module, M6-PSM must be mounted on the
power module slot of the M6NBS-08A.
M6NBS
8
Signal
• • • • • •
8
EM-7915 Rev.6 P. 1 / 4

Advertisement

loading
Need help?

Need help?

Do you have a question about the M6NBS and is the answer not in the manual?

Questions and answers

Summary of Contents for MG M6NBS

  • Page 1 • Keep space of at less 1 cm (0.4 inches) on the left side of Power Supply Module, M6-PSM must be mounted on the the power supply module (model: M6-PSM). power module slot of the M6NBS-08A. ■ WIRING • Do not install cables close to noise sources (relay drive cable, high frequency line, etc.).
  • Page 2 Panel bottom or wiring conduit (height ≤ 50 mm or 2 in.) ■ SURFACE MOUNTING • M6NBS-08 • M6NBS-08A 30.8 (1.21) 3-M4 3-M4 49.8 (1.96) 49.8 (1.96) • M6NBS-08 + M6NBS-08P • M6NBS-08A + M6NBS-08P 30.8 (1.21) n-M4 * n-M4 * 49.8 (1.96) 11.8 49.8 (1.96) 49.8 (1.96) 49.8 (1.96)
  • Page 3 Pull out the unit while pushing down the DIN rail adaptor Pull out the extension base while pushing the hooks at the with a minus screwdriver. top and the bottom. EM-7915 Rev.6 P. 3 / 4 MG CO., LTD. www.mgco.jp 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...
  • Page 4 [5 (.20)] 27 (1.06) 3–4.5 (.18) dia. 30.8 (1.21) MTG HOLE 2 (.08) deep DIN RAIL 35mm wide 49.8 (1.96) 22.5 (.89) 116 (4.57) EM-7915 Rev.6 P. 4 / 4 MG CO., LTD. www.mgco.jp 5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...