Operation - Graco PPM 100 Instructions Manual

Precision pulse volumetric fluid flow meter
Table of Contents

Advertisement

WARNING
Pressure Relief Procedure
To reduce the risk of serious injury, including
splashing fluid in the eyes or on the skin, or injury
from moving parts, fire, explosion, or electric
shock, always follow this procedure when shutting
off the system, when checking or servicing any part
of the spray system, and whenever you stop opera-
tion.
1. Turn off the fluid supply to the meter.
2. Shut off all electrical power to the fluid system
or air system.
3. Follow the Pressure Relief Procedure for your
fluid system dispensing device.
CAUTION
The flow meter rotor can be damaged if it rotates at
too high a speed. To avoid high speed rotation,
open the fluid valve gradually. Do not over-speed
the rotor with air or solvent. To prolong meter life,
Do not use the meter above the maximum flow rate
of 1000 cc/min. (34 oz/min.).
Recommended Usage
The flow meter can be used with fluids that are 0 to
50
C (0 to 122
F).
Use the flow meter with the filter provided, as abra-
sive fluids can cause problems with the rotor.
Turn ON
Press RESET
ON/OFF Button
To Turn OFF
NOTE: The meter will only turn-off in the "b" mode.
Fig. 4

Operation

Indicating "b"
Real Time Flow V olume
per minute
Press MODE button
When used with low viscosity fluids, such as sol-
vent, the flow meter will not be accurate at low flow
rates under 50 cc/min (1.69 oz/min). See graph,
page 16.
Do not use the flow meter with fluids that are not
compatible with the "Wetted Parts" listed in the
Technical Data on page 15.
Do not allow the fluid to set in the flow meter.
Before shutting down the system, flush the meter
as instructed in the Maintenance section.
Operating the Flow Meter
Follow the steps shown in Fig. 4 when turning the flow
meter ON or OFF or when changing the measuring
mode.
DETAIL
Indicating "C"
Total Free Flow V olume
for designated time
Press MODE button
(Resettable) Press
RESET ON/OFF button
to reset to zero
Indicating "A"
Real Time Flow V olume
per hour
Press MODE button
Blank Display
Total Flow V olume
going thru passage
Press MODE button
(Non-resettable)