8.0 YC elevator replacement parts 8.0 YC slip replacement parts 9.0 YC elevator wear data 10.0 Reception, storage, transport, decommissioning Certificate of warranty & guarantee of quality Manufacture Information & Revision History Keystone Keystone ENERGY TOOLS ENERGY TOOLS OP-12 Rev 11 - 04/08/2024...
Failure to inspect these parts could cause injury or death. Figure 1 Keystone DO NOT DISCARD – GIVE TO USER ENERGY TOOLS OP-12 Rev 11 - 04/08/2024...
Page 4
WARINING: For professional use only. Maintenance Hazards WARINING: Use only Keystone Energy Tool components on equipment. Failure to do so may affect the correct functioning of the tool and may cause injury or death.
3 ½”- 7" guide for proper field use, disassembling and repair. Figure 1 The Keystone “YC” series elevators are designed to be used on all API collar type or integral joint tubing. They NOTE: WARNING labels have been installed at are balanced making them easy to handle and easy to critical areas on the tool.
Lift the bottom of the link blocks and hook the small end of the links through the link blocks and link arms. Lower the link blocks and re-install the link block bolts, nuts and cotter pins. Keystone ENERGY TOOLS...
Inspect the bore, latch, latch pin and hinge pin regularly for wear. Make sure link block bolts are retained with nuts and cotter pins. Keystone ENERGY TOOLS OP-12 Rev 11 - 04/08/2024...
The owner/user of the equipment should develop schedules of inspection based upon experience, the manufactures recommendations, and one or more of the following factors. Environment Testing Load cycles Repairs Regulatory requirements Remanufacture Operating time Keystone ENERGY TOOLS OP-12 Rev 11 - 04/08/2024...
Check link block bolts for nuts and cotter pins Check link block bolts for nuts and cotter pins Grease Bore Grease the backs of the slips Maintenance Locations Keystone ENERGY TOOLS OP-12 Rev 11 - 04/08/2024...
Do not insert the pin or bolt completely and slip retaining bolt must be removed from the through the spring until both pins retain their elevator. respective slip body and slip spring. Keystone ENERGY TOOLS OP-12 Rev 11 - 04/08/2024...
Page 11
If the door lug pin is damaged, drive or press it Use only parts manufactured and sold by Keystone Energy Tools or one of KET’s authorized from the bottom of the lug. distributors. Inspect all parts for damage, wear, and cracks ...
Always wear gloves and safety goggles when disassembling the tool. Clean the tool with a steam cleaner. It is recommended to disassemble the tool in a place where drainage for waste fluids is possible. Keystone Keystone ENERGY TOOLS ENERGY TOOLS...
Keystone ENERGY TOOLS For more information, please contact us at: Keystone Energy Tools 3711 Melancon Rd. Broussard, LA 70518 www.k-e-t.com Office: 1-337-365-4411 Fax: 1-337-365-4456 Revision History Rev Date Changes 05/26/2021 Updated format/added rev history Cody H. Added page 11 figure 2 (insert retainer 03/10/2022 installation) &...