ACTUATOR FOR SWING GATES
Installation manual for the installer

Advertisement

loading
Need help?

Need help?

Do you have a question about the 300 and is the answer not in the manual?

Questions and answers

Summary of Contents for DTM System 300

  • Page 1 AUTOMATION SYSTEMS ACTUATOR FOR SWING GATES Installation manual for the installer...
  • Page 3 AUTOMATION MUST BE IMPLEMENTED IN ACCORDANCE WITH EUROPEAN STANDARDS: EN 12100 (Safety of machinery. Electrical equipment of machines. General requirements) EN 12445 (Gates. Safety in use of power operated doors. Test methods) EN 12453 (Gates. Safety in use of power operated doors. Requirements) The installer should provide the device with a residual current circuit breaker ensuring that the devices are disconnected from the power supply (EN 60335-1).
  • Page 4 Please read these warnings carefully. The gate drive ensures correct and safe operation only if the installation and use complies with the following safety rules. DTM System is not responsible for accidents resulting from improper use or unprofessional installation of devices.
  • Page 5 3 / 4 / 5 m - maximum gate weight 250kg - protection class IP-43 - thermal protection: 150°C - arm stroke: 300 / 400 / 600mm - leaf movement speed: 18mm/s - pulling force: 2200 N - engine speed: 1400 rpm - continuous operation...
  • Page 6: Mechanical Assembly

    DTM System remote gate controller external photocell Figure 2. Illustrative view of the gate automation installation. ATTENTION! The actuator cannot operate so that the piston extends or retracts completely. A correctly set actuator moves up to 95% of the extension when the gate is closed and up to 5% when the gate is open.
  • Page 7 The drives are not designed to operate continuously to their maximum ON time (continuous operation). The drive becomes too hot and switches off until it reaches the switch-on temperature again. The outside temperature and gate parameters are important factors that influence the actual switch-on time. The gate must operate evenly and without impact, the movement must be smooth and unobstructed.
  • Page 8 When the bracket is not stable enough, it must be strengthened. If we have a wooden gate, the gate fittings must be screwed through. It is then advisable to use a board from the outside so that the fastening cannot loosen over time. Thin wooden gates must be additionally reinforced to withstand the stresses that occur.
  • Page 9 Recommended dimensions DTM300 (mm) 640mm 95° 120° 1040mm Recommended dimensions DTM400 (mm) 740mm 95° 1122 120° 1122 1140mm Recommended dimensions DTM600 (mm) 940mm 95° 1532 120° 1532 1540mm If it is not pos s ible to obtain the dimensions given in the table, other dimensions can be determined - for a leaf opening of 90°...
  • Page 10 and movement of the gate should not be underestimated. Using the experimental method, we can achieve the best dimension for the opening angle we are interested in. The suggested dimensions A/B are shown in the table in Figure 7. If the pole is too thick, it should be cut out (Figure 8C) or the gate on the pole should be moved (Figure 8B).
  • Page 11 plug is glued into the wall in a stress-free manner, this is more suitable than the use of expansion, plastic or steel dowels. In the case of masonry columns, a relatively large steel plate must be screwed on to cover a few bricks, and then a hinge plate can be welded to it. You can also use an angle plate as a support plate, which can be screwed to the corner of the column.
  • Page 12: Important Reminder

    THE FORCE IN THE CONTROLLER MUST BE ADJUSTED SO THAT AFTER THE GATE IS COMPLETELY CLOSED, ITS EMERGENCY UNLOCKING IS POSSIBLE! Operating the actuator with excessive force, in addition to increasing wear of the actuator elements, will also cause excessive stress in the gear mechanism after the gate is fully closed.
  • Page 13 3.2. Connecting devices to the controller Connecting the devices to the controller should be the last installation activity performed in accordance with the instructions attached to the control unit. First, install the motors, lay the necessary cables and attach the safety devices. When installing the installation, use a main switch that cuts off the mains voltage.
  • Page 15: Terms Of Warranty

    TERMS OF WARRANTY DTM System delivers devices that are operational and ready for use. The introducer grants a warranty on the basis of a correctly completed warranty card and sales document. The introducer undertakes to repair the device free of charge if any defects occur during the warranty period due to the fault of the introducer.
  • Page 16 DTM System ul. Brzeska 7, 85-145 Bydgoszcz, Polska http://www.dtm.pl...