Instructions for the installer
380 - 415
V
380 - 415
V
220 - 240
V

10.2 Cable replacement

Should the supply cable need replacing,
remove the back guard by unscrewing the
screws to gain access to the terminal.
Replace the cable. The cable cross-
section must be no less than 1.5 mm² (3 x
1.5) (see 10.1 Electrical connection).
Make sure that the cables (for the oven or
any hob) follow the best route in order to
avoid any contact with the oven.
WARNING: The tightening torque of the screws of the terminal supply wires
must be 1.5 - 2 Nm.
3N~
five-core
2N~
four-core
1N~
three-core
5 x 1,5 mm²
H05V2V2-F
4 x 2,5 mm²
H05V2V2-F
3 x 4 mm²
H05V2V2-F
55