Page 1
Battery Monitoring Truck iQ™ Smart Battery Dashboard OWNER’S MANUAL UL Listing applies in the United States and to certain models only. www.enersys.com...
TPPL with ATP* ® ® • Truck iQ™ smart battery dashboard PN3 batteries • Touch screen display * Applies to North American version only; please contact your EnerSys representative for more ® details. Technical Specifications Item Description 15V to 120V (PN2)
Page 4
TECHNICAL SPECIFICATIONS Technical Specifications (cont.) Item Description Information PN2 Model: TruckiQ-10 Information PN3 Model: TruckiQ-20 Certified by UL to UL 583 ® Radio Spectrum (Directive 2014/53/EU - RED) FCC ID: T7V4561HM (Panasonic industrial 802.14.4 modem – 2,405-2,475GHz) FCC ID: WAP2001 (Cypress BLE PRoC – 2,402-2.48GHz)
DISPLAY DESCRIPTION & SETTINGS Main Screen The Truck iQ™ smart battery dashboard has a Mode Usage Touch Screen TFT 4.3 inch. Remaining Work Time Sleep/Eco/ Battery Temperature Normal/Heavy Figure 1: Main Screen Activation Button (only PN3): • Acknowledge warning • Turn on: short press will turn the battery on •...
Icon to acknowledge Active warnings fault. (Level >=3). Overload current warning (90% of the max limit) * Applies to North American version only; please contact your EnerSys representative for more details. ® Screen 2 Battery details • Type: Nominal battery voltage & kWh •...
Page 7
DISPLAY DESCRIPTION & SETTINGS Screen 2 (cont.) Cycle/trip details • Real time battery voltage • Real time current • Average consumption (trip) • Discharged kWh (trip) • Real time cells voltage min and max • Real time cells temperature min and max Truck information •...
Page 8
DISPLAY DESCRIPTION & SETTINGS Screen 2 (cont.) Password protection and SoC/Relay manual settings SoC/Relay threshold can be adjusted and set directly on the password protection display. General settings are not password protected (i.e. language, time, etc.).
NexsSys TPPL 30% SoC 20% SoC ® NexSys TPPL with ATP* 10% USoC 5% USoC ® NexSys 4% USoC** 2% USoC** ® *Applies to North American version only; please contact your EnerSys representative for more details ® **Are not adjustable...
DISPLAY DESCRIPTION & SETTINGS Menu Settings Option Setting Description Bluetooth BLE ON ON/OFF Enable/Disable BLE option CAN ON ON/OFF Enable/Disable CAN option Buzzer ON ON/OFF Enable/Disable Buzzer option PN3 – USoC threshold to activate buzzer warning Warning 1 beep every 30 sec Level Buzzer CDI settings are used, when installed...
DIMENSIONS AND INSTALLATION Dimensions Truck iQ™ smart battery dashboard Figure 2: Dimensions of a Truck iQ™ smart dimensions (mm) battery dashboard PN2 TRUCK - IQ SCALE: 1 28.03.18 SCALE 0.333 SCALE 0.333 163.09 30.7 39.86 Mechanical Installation Install the Truck iQ™ smart battery dashboard fixing bracket on the most suitable part of the truck.
INSTALLATION Electrical Installation Truck iQ™ smart battery dashboard cable specifications The cable provides a relay (NC) option, according to the following pin-out. M12A-04PMMP-SF8001 Description PN2 Power Supply cable 6LA20737 Reserved Reserved Relay* (common) Relay (NC) Not used *Relay: 62.5VA/60W – 2A – 250VAC/220VDC Communication via CAN according to the following pin-out.
INSTALLATION PN2 Truck iQ™ Smart Battery Dashboard Flooded and NexSys TPPL Batteries ® Truck iQ™ smart battery dashboard part number Connect the supply cable pins on the +VBAT 6LA20723-PN2 for Flooded and NexSys TPPL and –VBAT on the battery or on the truck side. ®...
INSTALLATION & COMMUNICATION PN2 Truck iQ™ Smart Battery Dashboard Flooded and NexSys TPPL Batteries (cont.) ® Turn the “fastening screw” on the connector to lock the supply cable to the Truck iQ™ smart battery dashboard. Power the Truck iQ™ smart battery dashboard by connecting the traction battery to the truck.
• Click BLE icon and select the correct Wi-iQ ® battery monitoring device that appeared with the associated battery serial name * Applies to North American version only; please contact your EnerSys representative for more ® details Auto Pairing • Navigate to: 1) Settings 2) I/O 3) Pairing 4) Enable Auto pairing.
PART NUMBERS Part Numbers Truck iQ™ for Nexsys TPPL/Flooded Truck iQ™ for Nexsys ION/Nexsys TPPL ATP ® ® ® 6LA20723-PN2 6LA20723-PN3 Metal Brackets 6LA20738 Power Supply Cable for No extra power supply 6LA20737-L2 (2m) 6LA20737-L4 (4m) CAN Cable for PN3 6LA20750-L2 (2m) CAN Cable for PN2 6LA20750-L4 (4m)
• Disable Auto pairing and enable it again • Scan the device BLE connection issues • Leave the Auto pairing disabled and select the appropriate Wi-iQ(R) device by clicking on the BLE icon Technical support: Refer to our website www.enersys.com to find your local contact.
Need help?
Do you have a question about the TruckiQ-10 and is the answer not in the manual?
Questions and answers