(2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. IN ACCORDANCE WITH FCC REQUIREMENTS, CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY ENERSYS COULD VOID THE USER’S AUTHORITY TO OPERATE THIS PRODUCT. Technical support: Reference www.enersys.com to find your local contact.
Page 4
2. TECHNICAL SPECIFICATIONS (CONTINUED) 2.4.2 Parameters displayed. Table 2: Parameters The Wi-iQ 4 Battery Monitoring Device ® 2.2.1 The Wi-iQ ® 4 battery monitoring device consists of: Description Value Comment • A main unit (for voltage measurement, display, LEDs, buzzer and communication features) 0-100% State of Charge of the battery...
2. TECHNICAL SPECIFICATIONS (CONTINUED) Figure 6: Probes and Sensors Wi-iQ ® 4 Device CAN option 2.7.1 If equipped, the Wi-iQ 4 device communicates via CAN protocol. ® 2.7.2 The Wi-iQ4 device main unit is delivered with a protective plastic cap that needs to be removed to use the CAN option.
5.3.1.1 Interface with truck using an Original Equipment Manufacturer (OEM) proprietary CAN protocol implemented. 5.3.1.2 Interface with AGV using EnerSys proprietary CAN protocol. Configuring Wi-iQ4 Device within Wi-iQ Reporting Suite 5.4.1 Once the device is installed, it must be set-up in the software. Plug a dongle (Wi-iQ antenna) into the USB port of a PC with the Wi-iQ Reporting Suite installed.
Page 7
Manufac. Bat.” Field. Enter the date the battery is placed in service for the “Date Inst. serv.” field. Leave all other date fields blank. 5.4.21 Owner – Leave as default – ENERSYS. 5.4.22 Battery Group – Enter truck type – Sit Down, Reach, etc., or as designated by customer.
Page 8
5. COMMUNICATION (CONTINUED) 5.4.38.1.2 Measure the voltage between the positive and 5.5.3 The main screens of the E Connect mobile app with the main negative battery post with a calibrated voltmeter. parameters are shown below. Divide the number of cells in the battery and Figure 15: E Connect Mobile App Screens confirm this value is within a tolerance of (+/- .03 VDC) of the value in “VBAT/CEL”.
System temperature (battery temperature) 5.6.2 The device consists of a display powered by the battery via the truck 5.7.1.6 For more details, please refer to EnerSys Global: CAN Open cables. It reads in real time and wirelessly data from the Wi-iQ ®...
Page 10
If installed correctly, inspect the 6.1.3.1.5.1 probe for corrosion. Replace probe if damaged. For service, contact your EnerSys sales represeentative or visit www.enersys.com.
Need help?
Do you have a question about the Wi-iQ 4 and is the answer not in the manual?
Questions and answers