Advertisement

Quick Links

ADPRO by Xtralis
PRO-45 / PRO-45H
Installation Manual
March 2010
Part 201361_06

Advertisement

Table of Contents
loading

Summary of Contents for Xtralis ADPRO PRO-45

  • Page 1 ADPRO by Xtralis PRO-45 / PRO-45H Installation Manual March 2010 Part 201361_06...
  • Page 3 Xtralis or its representatives. Total Liability To the fullest extent permitted by law that any limitation or exclusion cannot apply, the total liability of Xtralis in relation to the products is limited to: (i) in the case of services, the cost of having the services supplied again; or (ii) in the case of goods, the lowest cost of replacing the goods, acquiring equivalent goods or having the goods repaired.
  • Page 4 Equipment malfunction caused by lightning or related voltage surges is specifically exempted from the warranty conditions. Xtralis AG Pty Ltd reserves the right as to final determination of whether or not an equipment malfunction was caused by lightning or related voltage surges.
  • Page 5 ADPRO by Xtralis PRO-45 / PRO-45H Installation Manual Overview The PRO-45 / PRO-45H detectors are highly sensitive passive infrared detectors designed for detection outdoors with a narrow, curtain-shaped differential field of view. They incorporate microprocessor-controlled signal processing including signal shape analysis, adaptive threshold level by feedback of environmental effects, temperature compensation and rejection of disturbance signals.
  • Page 7: Table Of Contents

    ADPRO by Xtralis PRO-45 / PRO-45H Installation Manual Contents Mounting and Installation ................. 1 Hardware / Software Mode of Operation..........1 Connecting the PRO-45 / PRO-45H ............2 Alarm Signalling................2 Cover Tamper Switch ..............2 Electronics Supply................2 Anti-Tamper Output................ 2 Field of View....................
  • Page 8 Installation Manual ADPRO by Xtralis PRO-45 / PRO-45H 21.0 Specifications ...................15 Mechanical Dimensions ................16 Annex 1: Electronic Board and Terminal Block..........16 DIP Switches....................17 Annex 2: Two Way Communication RS485.............18 Annex 3: Installation Software ................19 Doc 10642_06...
  • Page 9: Mounting And Installation

    ADPRO by Xtralis PRO-45 / PRO-45H Installation Manual Mounting and Installation The mounting structure should be stiff enough and resistant to significant deflections in windy conditions. Movement of the PRO-45 / PRO-45H caused by vibrations or other movements will result in swings of the field of view covered by the PRO-45 / PRO-45H and could cause disturbance signals.
  • Page 10: Connecting The Pro-45 / Pro-45H

    Installation Manual ADPRO by Xtralis PRO-45 / PRO-45H Connecting the PRO-45 / PRO-45H For the definition of the connector board and terminal block refer to Annex 1: Electronic Board and Terminal Block for details. Alarm Signalling There are two types of alarm signalling from the PRO-45 / PRO-45H: ...
  • Page 11: Alignment

    ADPRO by Xtralis PRO-45 / PRO-45H Installation Manual Alignment The detection range of a PIR detector is not limited but a function of size, speed and temperature contrast of a target against its background. The PRO- 45 / PRO-45H should be aligned so that a natural or artificial background at the end of the range terminates the field of view.
  • Page 12: Typical Horizontal Alignment

    Installation Manual ADPRO by Xtralis PRO-45 / PRO-45H PRO-45H for a required detection range of 60 m The PRO-45H should be aligned vertically so that at least the lower half of a person standing upright at the maximum required range will be within the field of view (refer to Figure 2 –...
  • Page 13: Sensitivity Settings

    ADPRO by Xtralis PRO-45 / PRO-45H Installation Manual PRO-45H Horizontal alignment should be done to avoid unwanted signals being generated by targets (branches, bushes, fences) likely to be moved by wind (refer to Figure 4 – Top View of PRO-45H). Movement within the field of view will reduce the sensitivity of the PRO-45H by increasing the alarm threshold level and may lead to unwanted alarms.
  • Page 14: Adaptive Threshold Discrimination (Atd)

    Installation Manual ADPRO by Xtralis PRO-45 / PRO-45H Adaptive Threshold Discrimination (ATD) The background noise is constantly averaged and used to adjust the threshold levels for the alarm. This special feature reduces the probability of nuisance alarms caused by wind, moving vegetation or objects that have a thermal contrast, although usually weaker than a person.
  • Page 15: Test

    ADPRO by Xtralis PRO-45 / PRO-45H Installation Manual Test When doing a walk test using the CT 45 (refer to section 17.2), in HW mode DIP switch 5 must be set to “on“ or when operating the detector in SW mode the “test”...
  • Page 16: Led

    Installation Manual ADPRO by Xtralis PRO-45 / PRO-45H Hardware Mode When operating the detector in the HW mode, the anti vandal function is activated by setting DIP switch 6 to “on“. Switch 6 Anti Tamper Feature on (*) (*) Factory Setting.
  • Page 17: Internal Temperature Compensation

    ADPRO by Xtralis PRO-45 / PRO-45H Installation Manual 13.0 Internal Temperature Compensation The PRO-45 / PRO-45H is detecting radiation differences of a target against its background. In the course of the day and year the contrast of a person will vary considerably and affect the signal strength.
  • Page 18: Signal Processing

    Installation Manual ADPRO by Xtralis PRO-45 / PRO-45H 16.0 Signal Processing The sophisticated signal processing ensures optimum performance and reliability of the detector. The background noise is sampled and averaged over a large number of cycles, giving a noise dependent value for the alarm threshold and to start the adaptive signal shape analysis whenever a certain amplitude value is exceeded.
  • Page 19: Cordless Walk Tester Ct 45

    ADPRO by Xtralis PRO-45 / PRO-45H Installation Manual The input cable is 5.0 m long and is terminated with a RJ12 connector fitting into the test socket on the electronic board of the detector. The connection to the PC’s COM port is with a standard 3.0 m RS232 or with a 1.8 m USB cable (supplied with the IF 485B).
  • Page 20: Pole Mount Hardware Za P-L1

    Installation Manual ADPRO by Xtralis PRO-45 / PRO-45H Transmitter Description 1. Power and Communication plug: Connects to the detector’s test socket 2. Power LED: LED indicates correct connection and power. 3. Antenna: To be placed straight in the detector housing 17.3...
  • Page 21: Maintenance

    ADPRO by Xtralis PRO-45 / PRO-45H Installation Manual 18.0 Maintenance The detector has been designed to be virtually maintenance free but the following precautions are recommended: Visual inspection of the front window for accumulation of dirt on the outer surface or damage at intervals of approximately 6 months. Clean the surface with a paper tissue and avoid rubbing dirt into the surface.
  • Page 22: Wiring The Alarm Outputs

    If used with a product that supports tamper detecting inputs, the PRO detector can be connected to signal both cover tamper and alignment tamper. The product (eg ADPRO FastTrace by Xtralis) should have the alarm input configured as Dual-End-of-Line Normally Closed. The PRO detector should be...
  • Page 23: Specifications

    ADPRO by Xtralis PRO-45 / PRO-45H Installation Manual 21.0 Specifications Model PRO-45 PRO-45H Optical Nominal Range 50 m (165 ft) 60 m (200 ft) Width @ Nominal Range 3.3 m (11 ft) 3.9 m (13 ft) Mounting Height 2.5 … 4.0 m (8 … 13 ft) Detection Speed 0.2 to 5 m/s (0.7 to 17 feet/s)
  • Page 24: Mechanical Dimensions

    Installation Manual ADPRO by Xtralis PRO-45 / PRO-45H Mechanical Dimensions Annex 1: Electronic Board and Terminal Block Doc 10642_0...
  • Page 25: Dip Switches

    ADPRO by Xtralis PRO-45 / PRO-45H Installation Manual DIP Switches Sensitivity Function SW Settings HW Setting 100% HW Setting 75% HW Setting 40% Function Switches Function Not Used Test Anti-tamper Feature Not Used Not Used Doc 10642_06...
  • Page 26: Annex 2: Two Way Communication Rs485

    Installation Manual ADPRO by Xtralis PRO-45 / PRO-45H Annex 2: Two Way Communication RS485 Introduction The PRO-45 / PRO-45H is equipped with a RS485 interface for two-way communication between the detector and a PC or other control device. This communication link is used for detector set-up and remote adjustments as well as for signal monitoring.
  • Page 27: Annex 3: Installation Software

    ADPRO by Xtralis PRO-45 / PRO-45H Installation Manual In this mode it is not only possible to do all adjustments and signal monitoring remotely from the control room but also eventually to use the RS485 link for alarm signalling. When planning to use the PRO-45 / PRO-45H in this configuration, please consult the manufacturer for details about the protocol definitions.
  • Page 28 Your use of this document does not constitute or create a licence or any other right to use the name and/or trademark and/or label.This document is subject to copyright owned by Xtralis AG (“Xtralis”). You agree not to copy, communicate to the public, adapt, distribute, transfer, sell, modify or publish any contents of this document without the express prior written consent of Xtralis.

This manual is also suitable for:

Adpro pro-45h