  • Page 1 Installation manual IRON DOG 01-06 ©2024...
  • Page 2: Table Of Contents

    Fireplaces may be set up only in rooms or areas with no risk of danger due to their state, structure or intend- ed use. Other manuals accompanying the insert are to be considered. Subject to technical changes. Please read attentively this installation manual before the beginning of the installation. Installation manual IRON DOG 01-06 (1.9) © 2024 Brunner GmbH...
  • Page 3: Delivery Contents

    Please copy this serial number in the user manual. Im. 1: Identification plate © 2024 Brunner GmbH Installation manual IRON DOG 01-06 (1.9)
  • Page 4: Dimension Drawings

    DIMENSION DRAWINGS Iron Dog 01 Iron Dog 02 Installation manual IRON DOG 01-06 (1.9) © 2024 Brunner GmbH...
  • Page 5 Iron Dog 03 Iron Dog 04 © 2024 Brunner GmbH Installation manual IRON DOG 01-06 (1.9)
  • Page 6 Iron Dog 05 Installation manual IRON DOG 01-06 (1.9) © 2024 Brunner GmbH...
  • Page 7: Requirements To The Installation Area

    The floor area where the device is installed must be large enough and configured in such a way that it allows a proper operation of the stove. © 2024 Brunner GmbH Installation manual IRON DOG 01-06 (1.9)
  • Page 8: Installation

    See also the information in the chapter 'Distances'. Iron Dog 01, Iron Dog 02 and Iron Dog 06 The flue pipe socket can be converted from the rear wall to the top. The flue gas connector and dummy cov- er are each screwed on from the combustion chamber side with two hexagon socket screws.
  • Page 9: Distances

    Im. 5: Combustion air supply DISTANCES The floor area (BB) under and in front of the Iron Dog must consist of an incombustible cover. Details can be found in the technical data. © 2024 Brunner GmbH Installation manual IRON DOG 01-06 (1.9)
  • Page 10 If the U-value is <0.4W / m²K, you must provide additional thermal insulation measures (see DIN 18896: 2013-12). Im. 6: Recommended distances to the Iron Dog 01 - Iron Dog 05 Installation manual IRON DOG 01-06 (1.9) © 2024 Brunner GmbH...
  • Page 11: Combustion Air

    Ventilation lines or shafts must be tight and accessible for revision and cleaning. Ventilation air grilles cannot narrow the free cross section. © 2024 Brunner GmbH Installation manual IRON DOG 01-06 (1.9)
  • Page 12 (their components must have a fire resistance rating of >90 minutes (F90)). See also regional building law. Installation manual IRON DOG 01-06 (1.9) © 2024 Brunner GmbH...
  • Page 13: Chimney And Smoke Pipe Connection

    Therefore it is important to ensure sufficient room ventilation. Open doors and windows. Don’t stay in the room longer than necessary. Please read the user manual! © 2024 Brunner GmbH Installation manual IRON DOG 01-06 (1.9)
  • Page 14 20 cm from the flammable components must be maintained.The space in between must either be ventilated or filled with mineral building materials with low thermal conductivity. Installation manual IRON DOG 01-06 (1.9) © 2024 Brunner GmbH...
  • Page 15 Indirect heat output: N.A. kW Energy efficiency index: Fuel energy efficiency (at nominal heat output): 80,0 % Fuel energy efficiency (at minimum load): N.A. % Special precautions: see supplied product documenta- tion © 2024 Brunner GmbH Installation manual IRON DOG 01-06 (1.9)
  • Page 16 D-84307 Eggenfelden Reprinting and reproduction, even in part, only with the express permission of the publisher. Tel.: +49 (0) 8721/771-0 / Fax: +49 (0) 8721/771-100 Email: info@brunner.de Art.Nr.: 19873 Installation manual IRON DOG 01-06 (1.9) © 2024 Brunner GmbH...