Whynter ECO-FRIENDLY ARC-142BX - AIR CONDITIONER Manual

Whynter ECO-FRIENDLY ARC-142BX - AIR CONDITIONER Manual

Also See for ECO-FRIENDLY ARC-142BX:

Advertisement

Whynter ECO-FRIENDLY ARC-142BX - AIR CONDITIONER Manual

OPERATING CONDITION

MODE ROOM TEMPERATURE
COOL Higher than 62°F / 17°C
DRY Higher than 54°F / 13°C

Your portable air conditioner is supplied with a Leakage- Current Detection and Interruption (LCDI) plug. This plug reduces the risk of fire due to arcing faults in the power supply cord. Please follow the instructions below to ensure that LCDI plug works properly.

  1. Plug the power cord to a grounded wall outlet. Do not plug to a power strip or extension cord.
  2. Press the TEST button on the plug. This should trip the plug and cut the power to the air conditioner. If the plug does not trip and the unit comes on, please contact technical support.
  3. Press the RESET button to start the air conditioner.
  4. Do NOT use the TEST and RESET buttons to turn the air conditioner on and off.

IDENTIFICATION OF ACCESSORIES

IMAGE ACCESSORY NAME QUANTITY
Exhaust hose
Flat Mouth Adaptor
Round Adaptor (pre-installed on unit)
1 set
Window sliders and Clear plastic plug
(plug is in the upper corner of the plastic bag that holds the user manual)
1 set
Foam seal 3 pcs
Remote control and Batteries 1 set
Drain hose 1 pc
Activated Carbon filter (pre-installed on unit) 1 pc

IDENTIFICATION OF PARTS

Front
IDENTIFICATION OF PARTS - Front

  1. Control Panel
  2. Front Air Vent / Louvers
  3. Caster (four)
  4. Handle (both sides)

Rear
IDENTIFICATION OF PARTS - Rear

  1. Upper air filter
  2. Air outlet (hot air exhaust)
  3. Power cord outlet
  4. Upper air intake
  5. Upper drain port
  6. Lower air intake (Compressor)
  7. Lower air filter
  8. Lower drain port

OPERATING YOUR AIR CONDITIONER

Before you begin, thoroughly familiarize yourself with the control panel, remote control and all of the functions. Follow the symbol for the desired function. The unit can be controlled by the unit control panel alone or with the remote control.

CONTROL PANEL
CONTROL PANEL

  1. MODE
    Controls the 4 function modes: COOL, AUTO, Fan only and DRY.
  2. TIMER
    Turns the timer function on and off. To cancel the timer, press the Power button or set the timer to 0.0.
  3. POWER
    Turns the unit on and off.
  4. SLEEP
    Turns the sleep function on and off.
  5. FAN
    Controls the 4 fan speeds: HI, MED, LOW and AUTO. The fan speed indicator lights illuminates to show the set fan speed. When the AUTO speed is selected, none of the fan speed indicator illuminates.
  1. UP and DOWN
    Adjusts set temperature (1°C/ 2°F increments) or timer hours (0 – 24 hours).
    NOTE: This unit is capable of displaying set temperature in Fahrenheit or in Celsius. To convert from one to the other, press and hold the Up and Down buttons for 3 seconds.
  2. LED DISPLAY
    In Cool mode: shows set temperature in °C or °F and AUTO timer setting. In DRY and FAN only modes: shows room temperature. Error Codes: E1, E2 and E4: Unplug unit and restart in 5 minutes. P1: Bottom water tank is full; drain water from the unit
  1. SWING
    Turns on the auto swing function.

INSTALLATION INSTRUCTIONS

Location
The air conditioner should be placed on a hard and level surface strong enough to support theunit. The unit has casters and it should only be rolled on smooth, flat surfaces. Use caution when rolling on carpet surfaces. Do not attempt to roll the unit over objects.
Never place any obstacles around the air inlet or outlet and allow at least 20 inch of clearance for efficient air-conditioning.

Exhaust hose Installation
When you use this air conditioner unit, hot air must be exhausted out of the room to complete the air exchange of the condenser. Wh en the unit is operating in DRY or FAN only mode, no exhaust is required.

  1. Pull out about 6" of one end of the exhaust hose.
  2. Install the flat mouth and round exhaust connector on the exhaust hose by turning counter-clockwise. See Fig. 18a and 18b
  3. Push in the exhaust hose into the air outlet port at the back of the unit. Fig. 19 and Fig. 20.
  4. Only extend the exhaust hose to the necessary length. We do not recommend extending the exhaust hose more than 9' long. If you are interested in purchasing an additional 5' exhaust hose please contact info@whynter.com for retail sales information.

Window kit Installation
When you use this air conditioner unit, hot air must be exhausted out of the room to complete the air exchange of the condenser. When the unit is operating in fan-only mode, no exhaust is required.
Your window kit has been designed to fit most standard vertical and horizontal windows.
However, it may be necessary for you to modify the installation procedures for your window. Please refer to Fig. 8 and Fig.9 for minimum and maximum window openings.
Window kit Installation - Step 1
NOTE: If your window opening is less than the mentioned minimum length of the window slider kit, cut the slide bar with hole to fit window opening. Never cut out the hole on the window slide bar.
NOTE: When using the window kit on a window or sliding door it will cause the window or sliding door not to be properly closed and locked. Additional security measurements maybe needed.
The window slide bars can be fixed with the clear plastic bolt. Fig. 9a
Window kit Installation - Step 2

Window kit Installation in a double-hung window

  1. Open window or sliding door for approximately 5"
  2. Cut the foam seal (adhesive type) to the proper length and attach it to the bottom of the window. Fig.10.
    Window kit Installation in a double-hung window - Step 1
  3. Adjust the length of the window bars to the same length and width of the opening of the window. Cut the window piece if necessary to fit the length of your window. Fig. 11.
    Window kit Installation in a double-hung window - Step 2
  4. Close the window on the window slide bars. For long term installation, you may screw the window kit into your window frame. Fig. 12.
  5. Cut the foam seal to the length and seal the open gap between the top window sash and outer window sash. Shown in Fig.13.
    Window kit Installation in a double-hung window - Step 3

Window kit Installation in a sliding door/ window

  1. Open window or sliding door for approximately 5"
  2. Cut the foam seal (adhesive type) to the proper length and attach it to the bottom of the door / window. Fig.14.
  3. Adjust the length of the window bars to the same length and width of the opening of the window. Cut the window piece if necessary to fit the length of your window. Fig. 15.
    Window kit Installation in a sliding door/ window
  4. Close the door/ window on the window slide bars. For long term installation, you may screw the window kit into your window frame. Fig. 16.
  5. Cut the foam seal to the length and seal the open gap between the top window sash and outer window sash. Show in Fig.17.

AIR FILTER INSTALLATION

Your Whynter portable air conditioner is equipped with a 2 in 1 silver-ion coated washable prefilter and activated carbon filter. The washable pre-filter removes large particles such as dust, pet hair and dander.
The Activated Carbon filter is designed to remove smoke and other odors. It is recommended you replace the Activated Carbon filter every 2-3 months or as needed.

NEVER OPERATE THE AIR CONDITIONER WITHOUT THE AIR FILTER

  1. The pre-filter can be removed by pulling up the filter frame.
    AIR FILTER INSTALLATION - Step 1
  2. Pull up the pre-filter frame. This carbon filter can be removed out from the grille and replaced.
    AIR FILTER INSTALLATION - Step 2

OPERATION INSTRUCTIONS

BEFORE USING YOUR APPLIANCE

  • Remove the exterior and interior packing
  • Before connecting the appliance to the power source, let it stand upright for approximately 4 hours. This will reduce the possibility of a malfunction in the cooling system from handling during transportation

SWITCHING ON/OFF THE AIR CONDITIONER

  • The appliance can be switched ON or OFF by pressing the Power button on the control panel or the Power button on the remote control

COOLING MODE

  • In this mode, the air conditioner cools and dehumidifies the room. To activate this function mode, press the MODE button until the COOL indicator light comes on. When the cooling mode is set, the compressor will start in approximately 3 minutes. In cooling mode, hot air is exhausted from the outdoor exhaust port and the exhaust hose must be connected to exhaust out the hot air
  • The temperature setting range of this air conditioner is from 62°F / 17°C to 88°F / 30°C. To set the temperature, press theor buttons. This air conditioner has a 5°F temperature cushion which if the set temperature is within 5°F of the ambient temperature, the unit runs on fan only mode. This saves energy and prolongs the life of the compressor of the air conditioner
  • To set the fan speed, press the FAN button. In cooling mode, the difference in noise level between the 4 fan speeds is not very noticeable when the compressor is on. Try setting the unit to Fan only mode, you should be able to hear the difference between high and low fan speed settings

DRY (DEHUMIDIFYING) ONLY MODE

  • In this mode, the air conditioner only dehumidifies the room, the compressor will activate intermittently depending on the ambient temperature and the fan speed is set to LOW. To activate this function mode, press the MODE button until the DRY indicator light comes on. Please note that when switching function mode, there will be an approximately 3 minute transition time. In dehumidifying mode, do not connect the exhaust hose and let the warm air return to the room

AUTOMATIC MODE

  • When you set the air conditioner in AUTO mode, it will automatically select cooling or fan only operation depending on what temperature you have selected and the room temperature is close to the unit. The fan speed is automatically selected and cannot be changed
  • To operate the unit in Auto mode when the unit is on, press the Mode button until the indicator for "Auto" is lit

FAN ONLY MODE

  • In this mode, only the fan of the air conditioner runs and circulates the air in the room. To activate this function mode, press the MODE button until the FAN indicator light comes on. In this function mode, the temperature cannot be set. Subsequently, set the desired fan speed by pressing the FAN button. Fan Only mode requires that the exhaust hose be removed

TIMER (DELAYED SWITCH ON / OFF) FUNCTION

  • This function mode enables a delayed switch ON or delayed switch OFF of the air conditioner. The time (hours) delay can be set, enabled and disabled

SETTING SW ITCH OFF TIMER
With the air conditioner operating in any function mode, press the TIMER button. The TIMER OFF light will come on. Then set the desired time delay OFF hours by pressing the UP and DOW N buttons. The time increments are at 0.5 hour to up to 10 hours, followed by 1 hour increment up to 24 hours. When the delay time set has elapsed, the air conditioner switches off. To cancel the delayed switch off function, turn off the air conditioner or adjust the time setting to 0.0.

SETTING DELAYED SWITCH ON TIMER
With the air conditioner is off, press the TIMER button. The TIMER ON light will come on. Then set the desired time delay ON hours by pressing the UP and DOW N buttons. The time increments are at 0.5 hour to up to 10 hours, followed by 1 hour increment up to 24 hours. When the delay time set has elapsed, the air conditioner switches on. To cancel the delayed switch on function, turn on the air conditioner or adjust the time setting to 0.0.

SLEEP MODE
In this mode, the air conditioner gradually increases the set temperature in cooling mode, decreases the noise level and conserves energy. In Sleep and cooling mode, the set temperature is increased by 1°C/ 2°C in the first 30 minutes. The temperature will then increase by another 1°C/ 2°C after an additional 30 minutes. This new temperature will remain the same for 7 hours.
To activate this function mode, press the SLEEP button until the sleep indicated light comes on.

AUTO RESTART
In the event of a power outage, the air conditioner restarts at the previously set function mode and settings when power is restored.

CONTROLLING THE AIR FLOW DIRECTION
The louvers can be adjusted manually or automatically.
To adjust the air flow direction, manually move the louvers to the desired position. The maximum setting angle is about 60°.
NOTE: Keep the louver fully opened during operation.
To adjust the air flow direction automatically, press the SWING button to set the louvers at the desired angle. The louvers move up to an angle of 6° when the SWING button is pressed once. By pressing the SWING button for more than 2 seconds, the auto swing feature is activated.

NOISE LEVEL
Portable air conditioners may make sounds that are not familiar to you. The sounds listed below are normal. Noise reflecting off hard surfaces such as a floor or wall can make the sounds seem louder than they actually are.

  • The compressor may make a pulsating or high-pitched sound
  • Water running from the evaporator to the water tank may make a splashing sound
  • Refrigerant flowing may make a gurgling sound
  • Fan sound may come from front and back air vents

WATER DRAINAGE

When the water level of the bottom tray reaches maximum level, the unit will beep 8 times and the digital display will show P1 symbol. Also, the cooling or dehumidifying function will stop and the fan only function will start.

Manual drainage
To drain the water from the bottom try, carefully move the unit to a drain location, remove the bottom drain plug and let the water drain (Fig.25). The P1 symbol will disappear and the cooling or dehumidifying function can be started.

Continuous drainage
In COOL or DRY modes, remove the upper drain plug from the back of the unit and install the drain water hose (5/8 universal female mender) with ¾" hose. Place the open end of the hose to a drain area. (Fig.23 and 24).
Continuous drainage

REMOTE CONTROL
The portable air conditioner can be switched on by the remote control. To transmit signals from the remote control to the air conditioner, point the front part of the remote handset towards the control panel on the air conditioner. Reception of the signal is confirmed by a beep. The maximum signal transmission distance is approximately 8 meters / 26 feet.

NOTE:

  • Other appliances in the same room controlled by a remote control (TV, radio, stereo, etc.), may cause interferences
  • Electronic and fluorescent lamps may interfere with the signal transmissions between the remote control and the air conditioner
  • Remove the batteries if the remote control is not used for long periods

INSTALLING BATTERIES

  • Only use two dry LR03 AAA 1.5V Batteries (included) in the remote control
  • Always change both batteries at the same time

To insert the batteries, open the flap on the back of the remote control by sliding if off. Strictly adhere to the polarity signs on the bottom of the battery housing, close the flap once the batteries have been inserted.
REMOTE CONTROL

INDICATOR FUNCTION
1 – Mode Indicator Displays the current selected mode (Auto, Cool, Dry or Fan)
2 – Lock Indicator Indicates unit is on Lock mode
3 – Temp./Timer Display Displays temperature or timer setting
4 – Fan (High) Displays the selected high fan speed
5 – Fan (Medium) Displays the selected medium fan speed
6 – Fan (Low) Displays the selected low fan speed
7 – Timer Indicator Indicates Timer mode activated
BUTTONS FUNCTION
8 – Up Button Increases set temperature/time
9 – Down Button Decreases set temperature/time
10 – Mode Button Controls the 4 function modes: Auto, Cool, Dry & Fan
11 – On/Off Button Turns the unit On and Off
12 – Fan Speed Button Controls the 3 fan speeds: High & Low or Auto
13 – Swing Button Starts or stops louver movement and set louver angle.
14 – Sleep Button Enables Sleep mode
15 – Timer On Button Enables the On timer & set timer hours
16 – Reset Button Cancels all settings
17 – Timer Off Button Enables the Off timer & set timer hours
18 – Lock Button Locks all settings
19 – LED Display Button Turns on and off the display light

CARE AND MAINTENANCE

  • Switch off the air conditioner and disconnect the plug from the power outlet
  • Drain water by removing the drain plug
  • Always transport the air conditioner in an upright position only

CLEANING THE AIR FILTERS

  • To ensure the air intake is filtered properly and to assure that your air conditioner runs efficiently, it is recommended to clean the air filters at least once every two weeks
  • This unit has two air filters; the upper and the lower filters
  • Switch off the air conditioner and pull out the upper air filter from the unit (Fig 26)
  • Remove the lower filter by loosening the screw and taking down the air inlet grille. (Fig.27 and 28)
  • Use a vacuum cleaner or tap lightly to remove loose dust and dirt from the filters. Then rinse them thoroughly under warm or cold running water (no hotter than 100F.)
  • Dry thoroughly before re-inserting the filters


Never operate the air conditioner without the filter in place

CLEANING THE AIR CONDITIONER

  • Always switch off the air conditioner and disconnect the plug from the power supply outlet before cleaning the air conditioner
  • Use a soft damp cloth to wipe the body of the unit.
  • Never use harsh chemicals, oil-based products, detergents, chemically treated cloths or other cleaning solutions. These could possibly damage the body of the air conditioner

END OF SEASON STORAGE

  • Switch off the air conditioner and disconnect the power plug from the power supply outlet before cleaning the air conditioner
  • Clean the air filters
  • Drain the condensed water COMPLETELY
  • On a warm day, turn on the Fan only mode for half a day so that the inside can dry out completely
  • Wrapped the power cord and bundle it with the tape (Fig.29)
  • Remove the batteries from the remote controller
  • Disconnect the exhaust hose and cover the window with the adaptor cap. (Fig.30)
  • It is recommended that the air conditioner be put back into its original carton for storage

TECHNICAL DATA

Cooling capacity 14,000 BTU
Power supply 115v/ 60Hz
Maximum power input 1480 Watts
Maximum input 12 Amps
Dehumidifying capacity 71 Pts / Day
Thermostat 62°F / 17°C to 88°F / 30°C
Refrigerant R410A/14.8oz
Air flow (max.) 540 m3/ Hour
Fan speeds 4 (Auto, H, M, L)
Exhaust hose length 59" / 5'
Unit Dimensions 19.25" W x 15.75" D x 32" H
Unit W eight 76 lbs

TROUBLESHOOTING

Problem Possible Causes Solutions

The portable air conditioner does not turn on

  • Power failure / outage.
  • The automatic switch, line fuse, or breaker has been tripped
  • The power supply voltage is too low
  • The power cord is damaged
  • The L.C.D.I. power plug for the unit is tripped
  • The internal water reservoir is full and 'P1" appears on display
  • Restore the power supply
  • Flip the switch / change the fuse / turn the breaker back on. Also note that you may have too many appliances drawing power on one circuit, you may need to move the other appliances to another circuit
  • Move the unit onto another circuit with the correct voltage
  • Call for service. Only authorized personnel should replace damaged power cord or power plug
  • Press the Reset button on the L.C.D.I. power plug
  • Drain water from the air conditioner
  • Possible loose internal connection. Please contact Whynter for service
The unit turns on but the compressor does not turn on (the fan runs but the unit is not cooling)
  • The room temperature is outside of the operational tolerances of the unit
  • The Cooling mode is not on
  • The compressor has not turned on yet because of its time delay
  • The set temperature is too high
  • The internal water reservoir is full and 'P1" appears on display
  • This unit is designed to work in ambient temperatures of 63°F to 90°F
  • Press the MODE button until the COOL light is shown on the display
  • Give the compressor 3 minutes to turn on after the Cooling mode has been selected
  • Set the air conditioner to a lower temperature. It is recommended to set the temperature to at least 5°F of the ambient temperature
  • Either manually drain the water by removing the drain plug or allow the unit to exhaust the water itself by running the fan only mode. Then cooling will resume
  • Possible loose internal connection. Please contact Whynter for service
The air coming out of the unit is not very cold, or the airflow volume is weak
  • The filters are dirty or obstructed
  • The air intake or exhaust is obstructed
  • The unit is set in DRY or FAN mode
  • The unit is set to low fan speed
  • Clean the air filters
  • Make sure there is at least 20" of clearance from the air intake. Make the length of the exhaust hose is as short as possible
  • Set the unit to the cooling mode
  • Set the unit to a higher fan speed
The unit has worked for a long time, but the room is not cold enough
  • Windows or doors are open
  • There are too many people in the room
  • There is direct sunshine into the room
  • The room is a kitchen or with many heat-producing appliances
  • There is a server in the room
  • The room is too large
  • Close all windows and doors
  • You may need additional cooling or another air conditioner
  • Close curtains or blinds and try to minimize the amount of direct sunlight into the room
  • You may need additional cooling or another air conditioner
  • You may need additional cooling or another air conditioner
  • You may need additional cooling or another air conditioner

The unit is very noisy

  • The unit is not level
  • The surface underneath the unit is uneven
  • Low power voltage
  • Make sure the unit is on hard, level and stable surface
  • Move the unit to a location with a level and hard floor
  • Make sure the wall outlet and support the required power consumption of the air conditioner and do not use an extension cord

The unit leaks water

  • The unit is tilted or not leveled
  • The water tank is full
  • Make use the unit is leveled
  • Drain water from the drain plug at the back of the air conditioner

Fan speed cannot be changed

  • Fan speed differences are not very noticeable
  • The fan speed difference is not very noticeable when the compressor is on. Try setting the unit to Fan only mode, you should be able to hear the difference between high and low fan speed settings.

SAFETY PRECAUTIONS

Your safety and the safety of others are very important to us.
To reduce the risk of fire, electrical shock or injury when using your appliance, follow these basic precautions.
warningBefore the appliance is used, it must be properly positioned and installed as detailed in this manual.

  • Do not under any circumstances cut or remove the third (ground) prong from the power cord
  • Make sure this unit is connected to a correctly grounded power supply outlet.Do not use an extension cord or power strip
  • The power cord is UL listed. It has a built-in L.C.D.I. (leakage, current, detection, interruption) circuit breaker for added safety. If the power supply is interrupted, press the reset button to reconnect the unit to power source
  • It is recommended to use a separate circuit that its size should be 15 Amps for the air conditioner
  • Do not use an excessively wet cloth, industrial solvents, oil-based products to clean this portable air conditioner
  • To avoid the risk of shock, the product should never be used in bathrooms, shower rooms, or in any other steamy or wet areas
  • Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliances
  • Do not repair, disassemble and/or modify the unit by yourself
  • Always turn off the portable air conditioner when cleaning the air filter, and transporting
  • Do not turn this unit on and off by plugging and unplugging. Always use the ON/OFF switch

  • Transport the unit in an upright position only, or leave it in an upright position for at least 4 hours before first use
  • Ensure curtains or other objects are not obstructing the air inlet filters
  • Do not bend or crush the exhaust hose while in use
  • Always allow at least 20" of clearance around the unit for ventilation. Do not use this unit inside closets, cabinets and/or cramped spaces between furniture
  • This unit is optimized to operate in an ambient temperature of 64°F – 90°F
  • This unit must be installed in an area protected from the element, such as wind, rain, water spray or drips
  • The unit should not be located next to ovens, grills or other sources of high heat
  • Always place the unit on even and hard and level surface
  • Do not sit or place objects on the unit
  • Do not allow children to climb, stand or hang on the appliance. The air conditioner could tip over and get damaged and/or seriously injure somebody
  • Keep fingers out of the air intakes and air outlets
  • The appliance is an electrical appliance. To avoid injury from electrical shock do not operate it with wet hands, while standing on a wet surface or while standing in water. Do not use it in outdoors or in wet conditions
  • When positioning or moving the appliance, ensure it is not turned upside down or greater than 45° or more off level
  • This appliance is designed for household, non-commercial use only. Any other use will void the warranty
  • Do not plug into the power outlet before set up is completed
  • Do not operate this unit without the air filter(s)
  • Do not use harsh chemicals to clean the filter(s). Dry thoroughly before inserting the filter(s) into the unit
  • Do not add extra length to the exhaust hose by more than a total length of 9'. This will reduce the cooling efficiency of the portable air conditioner
  • At the end of each season, all water must be drained from the unit and filter(s) must be cleaned before storage

THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY IF THE ABOVE INSTRUCTIONS ARE NOT FOLLOWED.

www.Whynter.com

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Whynter ECO-FRIENDLY ARC-142BX - AIR CONDITIONER Manual

Advertisement

Need Assistance?

Do you have a question about the ECO-FRIENDLY ARC-142BX that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents