The Whynter compact CFC-free, lead-free, and energy efficient 10,000 BTU portable air conditioner, helps you stay cool while working with better environmental standards and reducing energy consumption.
This compact portable air conditioner, specially designed to be mobile, can be easily setup in almost any indoor location and is most commonly used in data closets / server rooms, bedrooms, classrooms and garages / workshops.
This Whynter ARC-101CW compact portable air conditioner features an ECO-FRIENDLY CFC-free GREEN R-410A refrigerant and lead-free RoHS compliant components.
TECHNICAL DATA | |
Model: | ARC-101CW |
Operational Modes: | Cool, Fan or Dehumidifier |
Cooling Capacity: | 10000 BTU |
Dehumidifying Capacity: | 70 Pts / day |
Fan Speed: | 3 Fan Speeds |
Filters: | Activated carbon filter and washable pre-filter |
Thermostat Control Range: | 61° - 89°F |
Timer: | 24 hour programmable timer |
Noise Level: | < 55 dBA |
Refrigerant: | R-410A |
Air Flow (at high speed): | 264 m3/h / 145 CFM |
Maximum Power Consumption: | 1000W / 9.4A |
Power Supply: | 115 V / 60Hz |
EER: | 10.0 |
Unit Dimensions: | 17" W x 14" D x 28" H |
Package Dimensions: | 23.6" W x 16" D x 30.7" H |
Net Weight: | 58 lbs |
Gross Weight: | 69 lbs |
ACCESSORY IMAGE | ACCESSORY DESCRIPTION | QUANTITY |
![]() | Exhaust Hose | 1 piece |
![]() | Window slider kit | 1 set |
![]() | Fixture | 1 piece |
![]() | Screws | 4 pieces |
![]() | Hose Connector to Window Kit with tab cut-outs | 1 piece |
![]() | Slide Locking Hose Connector to unit | 1 piece |
![]() | Cover | 1 piece |
![]() | Remote control | 1 piece |
![]() | Storage Cover | 1 piece |
Mode | Room Temperature |
Cool | Higher than 64°F |
Dehumidify | Higher than 60°F |
Your portable air conditioner is supplied with a Leakage-Current Detection and Interruption (LCDI) plug. This plug reduces the risk of fire due to arcing faults in the power supply cord. Please follow the instructions below to ensure that LCDI plug works properly.
Indication symbols on LCD: | |||||
![]() | Cooling mode | ![]() | High Fan speed | ![]() | Display set temperature |
![]() | Dehumidifying mode | ![]() | Medium Fan speed | ![]() | Stop display |
![]() | Fan only mode | ![]() | Low Fan speed | ![]() | Display timer setting: Auto Switch On/Off |
Power Button
Press to turn the air conditioner on and off
Mode Control
Press to change mode
Fan Speed Button
Press to change fan speed
NOTE: Unit does not need to be vented in Fan Mode
Timer Button
Press to program Timer Delayed
Switch ON or OFF function
Timer / Temp Set Control
Adjusts set temperature (1°C/ 2°F increments) or timer hours (0 – 24 hours).
LCD Display
Stop display
Condensed water may accumulate in the unit. If the internal tank becomes full, the Stop display will come on and the unit will not operate until the unit has been drained.
NEVER OPERATE THE AIR CONDITIONER WITHOUT THE AIR FILTER
Your Whynter portable air conditioner is equipped with a washable pre-filter and an Activated Carbon Filter.
The washable pre-filter removes large particles such as dust, pet hair and dander. The Activated Carbon filter is designed to remove smoke and other odors. It is recommended you replace the Activated Carbon filter every 2-3 months or as needed. Follow the steps below to install the filters.
The dehumidifying capacity of this unit is 70 pints per day. The patented self-evaporating function of the unit fully exhausts all condensation automatically in most environments when humidity is less than 70%. Areas with more than 70% humidity, the self-evaporating function can still exhaust about 98% of the moisture and the remaining 2% of moisture will be collected in the water tank of the air conditioner.
When there is excess water condensation inside the unit, the air conditioner stops running and illuminates the Stop light (refer to "CONTROL PANEL' section). This Stop light indicates that the water condensation needs to be drained using the following procedures:
The hose must be directed downward from the upper drain port to allow the condensed water to flow with gravity.
The air conditioner should be placed on a hard and level surface strong enough to support the unit. The unit has casters and it should only be rolled on smooth, flat surfaces. Use caution when rolling on carpet surfaces. Do not attempt to roll the unit over objects. Never place any obstacles around the air inlet or outlet and allow at least 20 inch of clearance for efficient air-conditioning.
When using the air conditioner, the hot air from the exhaust hose must be exhausted out of the room to complete the air exchange of the condenser. When the unit is operating in dehumidifying or fan-only mode, installation of the exhaust hose is optional.
Only extend the both hoses to the necessary length. We do not recommend extending more than 9' long. If you are interested in purchasing an additional 5' exhaust hose, please contact support@whynter.com for retail sales information.
The window kit has been designed to fit most standard vertical and horizontal windows (Fig. 4a and Fig. 4b). However, it may be necessary to modify the installation procedures to accommodate your window.
NOTE:
The appliance can be switched ON or OFF by pressing the POWER button on the control panel or the ON/OFF button on the remote control
In this mode, the air conditioner cools and dehumidifies the room. To activate this function mode, press the Mode Control until the Cooling indicator light comes on. When the cooling mode is set, the compressor will start in approximately 3 minutes. In cooling mode, hot air is exhausted from the outdoor exhaust port and the exhaust hose must be connected to exhaust out the hot air.
The temperature setting range of this air conditioner is from 61°F / 16°C to 89°F / 32°C. To set the temperature, press the or
buttons. This air conditioner has a 5°F temperature cushion which if the set temperature is within 5°F of the ambient temperature, the unit runs on fan only mode. This saves energy and prolongs the life of the compressor of the air conditioner.
To set the fan speed, press the FAN button. In cooling mode, the difference in noise level between the 3 fan speeds is not very noticeable when the compressor is on. Try setting the unit to Fan only mode, you should be able to hear the difference between high and low fan speed settings.
In this mode, the air conditioner only dehumidifies the room, the compressor will activate intermittently depending on the ambient temperature and the fan speed is set to LOW. To activate this function mode, press the Mode Control until the Dehumidifying indicator light comes on. Please note that when switching functions, there will be an approximate 3 minute transition time. In dehumidifying mode, the exhaust hose does not need to be vented. If the exhaust hose is vented, the room will be cooled as it dehumidifies. To prevent cooling, remove the exhaust hose from the window kit and allow the warm air from the rear to be re-circulated into the room. If room temperature is higher than 77°F, the fan speed can be adjusted. If room temperature is lower than 77°F, the fan speed is set at Low.
NOTE: When using Dehumidifying mode, venting the exhaust hose to the outside is not required. If vented, the warm air is exhausted to the outside and cooling within the room may occur. Additionally, if the exhaust hose is not vented, the unit may require more frequent draining. The air conditioner does not have a humidistat in which a specific humidity level can be set.
In this mode, only the fan of the air conditioner runs and circulates the air in the room. To activate this function mode, press the MODE button until the Fan indicator light comes on. In this function mode, the temperature cannot be set. Subsequently, set the desired fan speed by pressing the Fan button. Fan Only mode does not require the use of the exhaust hose.
DELAYED SWITCH ON/OFF
This function mode enables a delayed switch ON or delayed switch OFF of the air conditioner. The time (hours) delay can be set, enabled and disabled. The timer is adjustable between 1 - 24 hours.
With the air conditioner operating in any function mode, press the Timer button. The display timer setting will come on. Set the desired time delay OFF hours by pressing the and
buttons. The time increments are at 1 hour to up to 24 hours. When the delay time set has elapsed, the air conditioner switches off. To cancel the delayed switch off function, press the Timer button or turn off the air conditioner.
With the air conditioner is off, press the Timer button. The display timer setting will come on. Set the desired time delay ON hours by pressing the and
buttons. The time increments are at 1 hour to up to 24 hours. When the delay time set has elapsed, the air conditioner switches on. To cancel the delayed switch on function, press the Timer button or turn on the air conditioner.
In the event of a power outage, the air conditioner restarts at the previously set function mode and settings when power is restored.
Portable air conditioners may make sounds that are not familiar to you. The sounds listed below are normal. Noise reflecting off hard surfaces such as a floor or wall can make the sounds seem louder than they actually are.
This portable air conditioner is optimized to operate in an ambient temperature of 64°F – 90°F. The compressor circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly. This prevents over-heating of the compressor and possible circuit breaker tripping.
During the process of cooling, some water will be extracted from the air into the unit. Most of this water is used to cool and exhausted to the outside. If the unit is operated in high humidity or low temperature environment, water will be collected in the reservoir inside the unit. If the reservoir is full, the compressor will stop. To continue the cooling function, please drain the water. See "INSTALLATION - WATER DRAINAGE".
The portable air conditioner can be switched on by the remote control. To transmit signals from the remote control to the air conditioner, point the front part of the remote handset towards the control panel on the air conditioner. Reception of the signal is confirmed by a beep. The maximum signal transmission distance is approximately 8 meters / 26 feet.
NOTE:
INSTALLING BATTERIES
To insert the batteries, open the flap on the back of the remote control by sliding if off. Strictly adhere to the polarity signs on the bottom of the battery housing, close the flap once the batteries have been inserted.
Notes:
To ensure the air intake is filtered properly and to assure that your air conditioner runs efficiently, it is recommended to clean the pre-filter at least once every two weeks.
This unit has two air filters; a washable pre-filter and an activated carbon filter.
NOTE: The activated carbon filter is not washable. It is an optional filter and should be replaced every 2-3 months or as needed if used. Please contact support@whynter.com for retail sales information or visit whynter.com for a list of optional accessories.
Never operate the air conditioner without the pre-filter in place
This portable air conditioner comes with one end of season storage cover. We highly recommend that storage cover bag is utilized when the unit is not going to be used for a period of time.
To avoid danger of suffocation, keep this bag away from babies and children.
Note: Depending on use, it is recommended that the air conditioner be cleaned internally annually. Please contact Whynter at support@whynter.com for internal maintenance cleaning instructions.
Keep the exhaust hose as short and straight as possible
The exhaust hose removes heat from the room. It should remain as short and straight as possible without sharp bends or twists to maximize efficiency. If the exhaust hose must be extended, do not exceed 9'.
Turn the air conditioner on early
Turning the air conditioner on early instead of waiting until the hottest point of the day will allow the unit to be more effective. The air conditioner will not have to work as hard to cool the room down and maintain the set temperature.
Reduce heat sources
Direct sunlight, televisions, computers and other heat generating appliances work against the air conditioner by introducing heat into the space.
Keep the air filter clean
Regular cleaning will help keep your air conditioner working properly. Dusty filters and vents greatly reduce the airflow and efficiency of the unit.
Many common portable air conditioner problems are easily resolved. Try the troubleshooting suggestions below to see if the problems can be resolved before having to contact the service department.
Problem | Possible Causes | Solutions |
The device does not turn on |
|
|
|
| |
|
| |
The unit turns on but the compressor does not turn on (the fan runs but the unit is not cooling) |
|
|
|
| |
|
| |
|
| |
|
| |
The air coming out of the unit is not very cold, or the airflow volume is weak |
|
|
|
| |
|
| |
|
| |
The unit has worked for a long time, but the room is not cold enough |
|
|
|
| |
|
| |
|
| |
The unit is very noisy |
|
|
| Move the unit to a location with a level and hard floor | |
|
| |
The unit leaks water |
|
|
|
| |
Fan speed cannot be changed |
|
|
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY WHEN USING YOUR AIR CONDITIONER, FOLLOW THESE BASIC PRECAUTIONS:
Before the appliance is used, it must be properly positioned and installed as detailed in this manual.
THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY IF THE ABOVE INSTRUCTIONS ARE NOT FOLLOWED.
Please retain the original proof of purchase.
To register your warranty, please visit www.whynter.com and fill out the online Warranty Registration form. Please be sure to include a copy of your purchase invoice.
To obtain service or information, contact Whynter LLC via email at support@whynter.com or call 866-WHYNTER (866-949-6837).
www.whynter.com
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Whynter WHYNTER COOLSIZE ARC-101CW - AIR CONDITIONER Manual
Advertisement
Thank you! Your question has been received!
Need Assistance?
Do you have a question about the WHYNTER COOLSIZE that isn't answered in the manual? Leave your question here.