Clearance Dimensions - Fisher & Paykel RDV3486GDL Installation Manual

Professional range
Table of Contents

Advertisement

C

CLEARANCE DIMENSIONS

A Minimum width of ventilation hood installed above range
B Minimum vertical distance between countertop and cabinet extending above counter
C Minimum clearance from left and right edge of range to nearest vertical combustible surface
D Minimum clearance from cook surface to:
combustible surface centered above the cook surface
z
combustible covering for ventilation hood centered above the cook surface*
z
non-combustible surface centered above the cook surface*
z
E Maximum overall depth of overhead cabinetry
F Width of cabinetry opening
G Maximum height from floor to countertop:
– for level counter
– with range levelling legs fully extended
H Maximum depth from wall to cabinetry face:
proud control panel
z
flush control panel
z
* Guidance dimension only. Combustible covering for a ventilation hood and non-combustible surface clearances are governed by local codes rather than these dimensions.
* Non-combustible surfaces: as defined in 'National Fuel Gas Code' (ANSI Z223.1, Current Edition). Clearances from non-combustible materials are not part of the ANSI Z21.1 scope
and are not certified by UL. Clearances of less than 6" (152mm) must be approved by the local codes and/or by the local authority having jurisdiction.
CLEARANCE DIMENSIONS – GAS AND COMBINATION COOKTOP MODELS
A
D
B
C
G
electrical
and gas
F
FRONT
30" MODELS
36" MODELS
48" MODELS
IN
MM
IN
MM
30
762
36
914
18
457
18
457
12
305
12
305
54
1372
54
1372
36
914
36
914
30
762
30
762
13
330
13
330
30
762
36
914
35 3/4
908
35 3/4
908
35 3/4
36 3/4
933
36 3/4
933
36 3/4
25 3/8
644
25 3/8
644
25 3/8
27 11/16
703
27 11/16
703
27 11/16
E
H
ISO
Note:
The cooking surface must sit flush or
IN
MM
z
above the adjacent countertop level.
48
1219
If the range is to be placed adjacent
z
to cabinets, the clearances shown are
18
457
required. The same clearances apply
12
305
to island installations.
The range can be placed in various
z
54
1372
positions with respect to the cabinet
front, with the control panel either
36
914
flush or projecting, depending on the
30
762
cabinetry depth.
13
330
The electrical and gas supply should
z
be within the zones shown in the
48
1219
following diagrams
Any openings in the wall behind the
z
908
range and in the floor under the range
933
must be sealed.
Always keep the appliance area clear
z
and free from combustible materials,
644
gasoline and other flammable vapors
703
and liquids.
Do not obstruct the flow of combustion
z
and ventilation air to the unit.
9