Other Circuits Диета Вн - Icom IC-2GA Service Manual

Hide thumbs Also See for IC-2GA:
Table of Contents

Advertisement

4-5
OTHER CIRCUITS
(1) S/RF METER CIRCUIT (LOGIC UNIT)
The voltages detected at the S-meter detector (Q4, Q5, D7)
or the APC detector (D13, D14) are applied to pin 2 of IC502
(1/2).
When
the voltage level is detected,
IC503 (pin 52)
outputs
a
"HIGH"
signal.
Because
the
signal
passes
through an integrator circuit (C507, R517), the voltage at
pin 3 increases with time.
When
the voltage at pin 3 is
greater than that at pin 2, pin 1 outputs a "HIGH" signal to
IC503 (pin 51). When
ІС503 (pin 52) becomes "HIGH," the
S/RF level, calculated from the delay time, is displayed.
А/О!
A/DO
ву
(IC503 PIN51) _ (IC503 PIN52)
S/RF signal
C507
C511
(2) LAMP CIRCUIT (LOGIC UNIT)
When
the LIGHT
SWITCH
is pushed, the IC503 (pin 53)
LAMP signal becomes "HIGH." The current of this signal is
amplified at Q501 to light the two chip-type LED (DS502,
DS503).
+5S is divided over R523 and R524.
1.16 V are applied to
IC502B
(pin 5). The Vcc voltage, divided over R525 and
R526, is applied to pin 6. When the Vcc voltage exceeds
5.7 V, the voltage at pin 6 becomes greater than that at pin
5. Output pin 1 becomes "LOW." When the Vcc voltage is
less than 5.7 V, the voltage at pin 5 exceeds that at pin 6.
Pin 1 outputs "HIGH." The TRANSMIT INDICATOR does not
light even when transmitting.
| (4) BEEP CIRCUIT (MAIN UNIT)
When some switches are pushed, the CPU sends BEEP data
to IC102.
Beep tones
are output from
1С202
(pin 5) in
square waves of about 1 kHz and 500 Hz.
(5) POWER SAVER CIRCUIT (MAIN UNIT)
When the squelch is closed, IC503 (pin 41) BUSY signal is
"LOW."
If no operation
is performed
for more
than
30
seconds,
the power
save
function
is automatically
acti-
vated.
After 30 seconds, the ІС503 sends power save data
to 12202.
SQL LOW
BEEP OFF POWER
1
1C202
2
SHIFT
3
REGISTER
РЭС
TMUT
STANDBY
STANDBY
SHUT-
SHUT-
SHUT-
DOWN
DOWN
DOWN
^ 500 " T 500 ` ` 500
msec
msec
msec
125
125
msec
msec
Using this data, 12202 (ріп 12) alternately outputs "HIGH"
(shut-down) for 500 msec.
and "LOW"
(standby) for 125
msec.
This output, applied to IC203D (pins 5 and 6) and
IC023C (pin 9), controls the bases of O211 and Q213 — thus
controlling +5S and R+5.
If a signal is received, the BUSY signal becomes
"HIGH,"
shutting off the power
save function.
If a signal is not
received, "HIGH" and "LOW" signals continue to alternate.
When the tone encoder is turned on, the X601
reference
frequency
(3.579545 MHz)
is divided
by IC601's
dividing
ratio
based
on
6-bit
data
from
1С503.
А
tone
(67.0 Hz~250.3 Hz) is output from pin 1. The tone output
passes
through
R601
for
deviation
adjustment
and
is
supplied to the MAIN UNIT.
(7) TONE CALL (IC-2GE)
Pushing the TONE CALL SWITCH
(S206) turns on Q218.
A
voltage is applied to IC206.
1C206 divides 7.168 MHz
by
4,096; and outputs a 1750 Hz tone through
pin 4.
R242
provides deviation adjustment.
(8) DTMF ENCODER (IC-2GAT)
IC801
generates
DTMF
tone signals.
When
transmitting,
T+5 V are applied to IC801 (pins 1 and 2). If, at this time,
data are entered with the keypad, the frequency (3.58 MHz)
oscillated by X801
is divided
by the appropriate dividing
ratio.
Pin 17 outputs
audio frequencies
coresponding
to ROW
and COL input. R801 provides deviation adjustment.
When
a key is pushed, a "HIGH" signal is output to pin 11. Q801
is turned on for about one second to maintain transmission
without pushing the PTT switch.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ic-2gatIc-2ge

Table of Contents