ELECTRICAL CONNECTIONS 1 Antenna. 2 Electronic equipment container. 3 Screened coaxial cable. 4 Electrolock 5 Key-selector; cable with 3 conductors of 0.5 mm². 6 220-230V operators; power supply, cable with 4 conductors oF 1.5 mm² each: grey=motor common, brown= opening phase, black= closing phase. 7 Power supply line to equipment 220-230V 50-60Hz, cable with 3 conductors of min.
Page 3
TOP 291 TOP 391 TOP 441 *(TOP 291/S) *(TOP 391/S) *(TOP 441/S) ALIMENTATION/POWER SUPPLY 220/230V-50Hz 220/230V-50Hz 220/230V-50Hz ABDORBED POWER 170 W 190 W 190 W *(170W) *(190 W) *(190 W) ABDORBED CURRENT 0,74 A 0,83 A 0.83 A MOTOR OVERLOAD 100°...
INSTALLATION OF THE OPERATORS PRELIMINARY WARNINGS Check that the gate structure meets the standards laid down in the regulations in force and that the gate movement is linear and without friction. It is recommended to carry out any operations necessary before installing the operator and in particular to always fit the mechanical end-stops.
Page 5
MOUNTING DIMENSIONS FOR THE SWING TO OPEN COTAS β TOP 291 90° TOP 291 110° TOP 391 90° TOP 391 110° TOP 441 1235 90° TOP 441 1235 110° If it is not possible to maintain the dimensions A and B indicated in the table,...
Page 6
OPERATORS TO BE INSTALLED ON BIG PILLARS OR W ALLS. MAKE AN ADEQUATE NOTCH IN THE PILLAR OR IN THE WALL ACCORDING TO DIMENSIONS «A» - «B» AS PER THE TABLE ON PAGE 6. WE RECOMMEND TO PUT AN ANTI-CRUSHING PROTECTION CARTER.
Page 7
CARE TO RESPECT THE DIMENSION “D” AS DESCRIBED ON PAGE 12 OF THE MANUAL. -SPREAD A DROP OF LOCTITE 270 STRONG THREAD RETAINER ON THE THREAD OF PIN “a” (FOR TOP 291) OR PIN “b” (FOR TOP 391/441). TIGHTEN WITH A #17 WRENCH UNTIL IT FITS INTO PLACE.
FORCE ADJUSTMENT 1) Valve for adjusting force during opening phase. 2) Valve for adjusting force during closing phase. Use a screwdriver to increase the force by rotating clockwise the opening valve (1) and the closing valve (2) located under the operator. Decrease the force by rotating counterclockwise valves (1) - (2).
MANUAL OPERATION DEVICE FOR MANUAL OPERATION Turn the cover 1 and lift it, turn the unlocking key 2 anticlockwise by 2 turns and carry out the manual manoeuvre. To reset, turn the key 2 clockwise until it stops without forcing it , and replace the cover into its original position.
Page 11
MANUAL OPERATION DEVICE FOR MANUAL OPERATION Push the cover 3 in the direction of the arrow, insert the key 4 in the lock 5, turn the key clockwise, turn the unlocking key 2 anticlockwise by 2 turns and carry out the manual manoeuvre. To reset, turn the key 2 clockwise until it stops without forcing it, turn the key 5 anticlockwise, and replace the cover 3 into its original position.
Page 12
Via Abetone Brennero, 177/B, 46025 Poggio Rusco (MN) ITALY Declares that the products: Linear hydraulic operator: TOP 291, TOP 391, TOP 441 Are in conformity with the following CEE Directives: • LVD Directive 2006/95/CE and subsequent amendments; • EMC Directive 2004/108/CE and subsequent amendments;...
Page 13
GI.BI.DI. S.r.l. Via Abetone Brennero, 177/B 46025 Poggio Rusco (MN) - ITALY Tel. +39.0386.52.20.11 Fax +39.0386.52.20.31 E-mail: comm@gibidi.com Numero Verde: 800.290156 w w w. g i b i d i . c o m...