  • Page 1 Made by...
  • Page 2 Dear Customer, Thank you for choosing HE series,a Ferroli electric water heater featuring advanced design, cutting-edge technology, high reliability and quality construction.Please read this manual carefully and keep it for future reference. Index 1.Introduction 2.General view and main components 3.Technical data table 4.Installation...
  • Page 3 General view and main component Introduction HE series is a high-efficiency heat generator for hot water production running on electric power and regulated by an advanced temperature setting system. Thanks to the integrated POLY insulating technology,the product equipped with extra thick insulating layer which can effective prevent the heat loss from the out shell and save the energy.
  • Page 4: Technical Data Table

    Technical data table Step 2:Water pipe connection Select the water inlet and outlet for HE-150 HE-200 HE-300 supplying hot water,first,install check Gasket valve in the hexagonal joint,then co- Internal and Hot water outlet external nut nnect the inlet pipe and outlet pipe valve with the safety valve...
  • Page 5 4.If water heater is installed with a water valve on cold inlet du- Install one electric box on dry place which can't be sprayed with water ,install one qualifyed leakage switch and air switch(30A/230 ring working period,this valve must be always kept open. V)in the electric box,connect the power cable of water heater with 5.During the heating period,it is normal if there is any water drops air switch ,trun on/off the power supply of waterheater through...
  • Page 6: Troubleshooting

    Trouble shooting Fault possible Cause Cure Incorrect connection of pipes Connect correctly No water comes out Valve blocking Clean or replace the valve Check electrical No power connection connection ON/OFF indicator Overheating occurs Call customer service not working Indicator breaks Temperature setting knob has Turn the knob towards not been switched to "High"...