  • Page 1 User Manual Patient Chair MOON OMS MOON S.T.01/3L ED.2 REV.0 05/2021...
  • Page 2: Table Of Contents

    SCHEDULED MAINTENANCE ..............................38 6.3. FUNCTIONAL AND SAFETY CHECKS ............................38 6.4. EXTRAORDINARY MAINTENANCE ............................39 TECHNICAL INSTRUCTIONS FOR INSTALLATION ......................41 7.1. PACKING ....................................41 7.2. INSTALLATION ..................................41 7.3. POST INTALLLATION CHECK ..............................42 OMS MOON S.T.01/3L ED.2 REV.0 05/2021...
  • Page 3 Please read this manual carefully before using the unit. For Information on OEM products, please refer to OEM documentation. This document is destined for dental care professionals.Describes the dental chair and its different parts as well as instructs how to operate and clean the dental unit. OMS MOON S.T.01/3L ED.2 REV.0 05/2021...
  • Page 4: General Information

    The chair is available in 2 versions, with fixed installation or on wheels to be moved. FIXED AND PERMANENT INSTALLATION MOVEMENT ON WHEELS INSTALLATION OMS MOON S.T.01/3L ED.2 REV.0 05/2021...
  • Page 5: Symbols

    Warning, important information for users and technicians. 1.2. SERVICE O.M.S. SPA Officine Meccaniche Specializzate Via Dante 20/A 35030 Caselle di Selvazzano (PD) Italia tel: +39 0498976455 - www.omsdentalunits.com e-mail: aftersales@omsdentalunits.com Always comunicate the serial number of the device. OMS MOON S.T.01/3L ED.2 REV.0 05/2021...
  • Page 6: For Your Safety

    Do not use the device if any part is defective or worn out. In this case, request the assistance of O.M.S. authorized technicians. CAUTION Replace the faulty or worn parts only with original spare parts, guaranteed O.M.S. OMS MOON S.T.01/3L ED.2 REV.0 05/2021...
  • Page 7 DANGER When servicing the unit or in case of maintenaince, always switch the unit off. OMS MOON S.T.01/3L ED.2 REV.0 05/2021...
  • Page 8 CAUTION During the automatic movement of the chair the dental user must stay closer to the dental unit. CAUTION Do not sit on the heatrest or on legrest lower part of the chair. OMS MOON S.T.01/3L ED.2 REV.0 05/2021...
  • Page 9 DANGER Patient chair on wheels: the positioning of the chair should be done without the patient. CAUTION Patient chair on wheels: handling area must be completely cleared. OMS MOON S.T.01/3L ED.2 REV.0 05/2021...
  • Page 10: Intended Use

    1.6. WARRANTY The standar warranty period of OMS is 36 (thirty six) months , from the date of installation belong to the end customer. The warranty conditions are shown inside the warranty book supplied with the device. The warranty is applied to the end customer and follow the product specified INSTALLATION AND INSPECTION...
  • Page 11: Technical Characteristics

    140 Kg Maximum load permitted on the patient chair 200 Kg with cupidor on the floor (not attached) 155Kg with cuspidor attached to chair, Minimum space recommended for installation about 3.20x3.00x3.00 m (LxHxP) OMS MOON S.T.01/3L ED.2 REV.0 05/2021...
  • Page 12 DIMENSIONS NOTE: The measures are to be considered indicative and might change according to the configuration of the dental unit and backrest type. OMS MOON S.T.01/3L ED.2 REV.0 05/2021...
  • Page 13 , if installation , calibrations, and repairs has not been performed by technical authorized and qualified O.M.S. with instructions and components exclusively provided from O.M.S. Electrical installation are carried out according to the appropriate requirements IEC. Equipment is used according to the instruction manual. OMS MOON S.T.01/3L ED.2 REV.0 05/2021...
  • Page 14: Symbols On Product Labels

    Rated current • Rated power • SN: Device serial n° • Manufacturer • WEEE symbol • MD: Medical Device symbol • Applied part Type B • Mandatory, see enclosed documentation • Follow operating instructions OMS MOON S.T.01/3L ED.2 REV.0 05/2021...
  • Page 15: Command - Control - Warning

    3.2. CALIBRATING SENSOR SAFTELY BACKREST To calibrate the backrest’s sensore from the MOON Chair, follow the procedur: Drive the chair or complete dental Unit, into the upper position; Use a small flat screew driver, inside the hold , and turn the trimmer , (see the following picure ), turn it clockwise to decrease the sensibility or turn it anti clockwise to increase the senibility;...
  • Page 16 Note: If you are not longer able to drive down the chair o backrest, make sure that the LED under the seat is OFF. If not re do the calibration of the sensor following the procedure into the point 3.2. OMS MOON S.T.01/3L ED.2 REV.0 05/2021...
  • Page 17: Chair Command From Footcontrol

    3.3. CHAIR COMMAND FROM FOOTCONTROL MOON chair has not the manual comand, on the backrest, it has been done to get a lower thinkness backrest. However the chair can be drive by an optional pedal installed on the lower back base . (see the picure on the this side).
  • Page 18 Note: All electric movements of the chair are equipped with electro-mechanical limit switches. Once you have reached the limits of the chiar or backrest, they automatically break down the power of the motors. OMS MOON S.T.01/3L ED.2 REV.0 05/2021...
  • Page 19: Automatic Buttons For Chair

    On the base of the chair has been installed the automatic position buttos, that can be used in different way, dipend of which unit has been intalled. 3.1.1. MOON INSTALLED WITH DENTAL UNITS: LINEA ESSE – ESSE PLUS - LINEA PATAVIUM – PATAVIUM PLUS – TEMPO 9 ELX KART – DUKE EASY 3.1.1.1.
  • Page 20 ZERO POSITION . Press again M3 to go back to the latest work position. 3.1.1.4. PRE SET MEMORY M4 Need to start from different position from ZERO POSITION the button M2 will work as M4. OMS MOON S.T.01/3L ED.2 REV.0 05/2021...
  • Page 21 If the position of Chair is ZERO , button M4, will work as M2 3.1.1.5. SAVE THE ZERO POSITION The MOON chiar allows to the user save the best ZERO POSITION. However the factory default settings has already the ZERO POSITON SAVED How to modified the ZERO POSITION:...
  • Page 22 Before to save the pre set M4 need to be “used/called” (see par. 3.1.1.4. PRE SET MEMORY M4), then drive the chair to the position where you want to save the M4. Keep pressed button M4 (see picture) upon the signal beep is heared. OMS MOON S.T.01/3L ED.2 REV.0 05/2021...
  • Page 23 M2/M4 M2/M4 3.1.2. MOON CHIAR with Dental Units: CARVING – CARVING PLUS – DUKE – DUKE 2020 – LINEA PATAVIUM 2020 – PATAVIUM PLUS 2020 – VIRTUOSUS – VIRTUOSUS PLUS – VIRTUOSUS 2020 – VIRTUOSUS PLUS 2020 - PUNTO KART 3.1.2.1.
  • Page 24 The button of rinsing position /last position can be found on the base of the chair (Button C ). If that button is pressed, the chiar goes automaticly to the rinsing position, by pressing it again after rinsing the chiar goes to the latest position has been in use. OMS MOON S.T.01/3L ED.2 REV.0 05/2021...
  • Page 25: Chair

    It is also possible to lower the joint mechanism in a position that gives the headrest greater comfort for childrent patients Note: Once the headrest has been adjusted to the working position, place back the lever to lock the movement. OMS MOON S.T.01/3L ED.2 REV.0 05/2021...
  • Page 26: Double Joint Headrest Click

    ; manually set the headrest to the requiered angle, then lock again. Note: Once the headrest has been adjusted to the working position, place back the lever to lock the movement. OMS MOON S.T.01/3L ED.2 REV.0 05/2021...
  • Page 27: Headrest With 3D Moviment

    ; manually set the headrest to the requiered angle, then lock again. Note: Once the headrest has been adjusted to the working position, place back the lever to lock the movement. OMS MOON S.T.01/3L ED.2 REV.0 05/2021...
  • Page 28: Armrest

    ARMREST The Moon chair has a left armrest always installed as optional can be installed the right armrest; the right armrest has a button (on the lower part), by pressing that button unlock the armrest and can be move forward o backwards The armrest can be also completly removed.
  • Page 29: Position Version On Wheels

    DANGER Patient chair on wheels: the positioning of the chair must be carried out without the patient. CAUTION Patient chair on wheels: The movement area must be completely cleared. OMS MOON S.T.01/3L ED.2 REV.0 05/2021...
  • Page 30 1. Press to the pedal to realease. Move the chair closer to the column of the unit on the side of the cuspidor Picture of pedal in neutral position: press the pedal on the left side to lift the swiveling wheel. OMS MOON S.T.01/3L ED.2 REV.0 05/2021...
  • Page 31 2. Get closer the footprint base with the left side of the cuspodir. OMS MOON S.T.01/3L ED.2 REV.0 05/2021...
  • Page 32 3. Place the chair on the side of the cuspidor colum. Check that the long side is perfectly parallel. OMS MOON S.T.01/3L ED.2 REV.0 05/2021...
  • Page 33 Swiveling wheel DANGER Chair on wheels: before the patient be seated down on chair make sure the platfortm for is stuck on the ground by using the stop pedal. OMS MOON S.T.01/3L ED.2 REV.0 05/2021...
  • Page 34 Chair on wheels: before carrying out any moving of the chiar platform , disconnect the power supply, the power supply must be connected only after the correct positioning with the cuspidor of the dental unit. OMS MOON S.T.01/3L ED.2 REV.0 05/2021...
  • Page 35: Maintenance

    6. MAINTENANCE To guarantee the dental unit’s proper operation, the unit must be checked and serviced by a qualified OMS services technican according to the maintenance schedule that has been set for your dental units. In the annual maintenance, “CARE KIT” the service technican replaces all parts specified by the Care Kit. These include, but are not limited to, parts in contact with air, water and suction system.
  • Page 36 For daily cleaning and disinfection use a little aggressive product such as: • SK SURFACES DISINFECTOR O.M.S. provides, on request, the tested and proven products in the company. Note: O.M.S. declines all responsibility for problems or damages caused by using different productor than those recommended. OMS MOON S.T.01/3L ED.2 REV.0 05/2021...
  • Page 37 PATIENT CHAIR Note: Daily cleaning and disinfection must be done with approved OMS products. DO NOT use agresive product for daily upholstery cleaning The deep cleaning of the upholstery, armrests and headrest shall carry out every 90 days, with products suitable for the treatment and following this procedure: 1.
  • Page 38: Scheduled Maintenance

    6.3. FUNCTIONAL AND SAFETY CHECKS To guarantee the dental unit’s proper operation, the unit must be checked by a qualified OMS services technican according to the maintenance schedule that has been set for your dental units Medical devices are built to ensure safety even in the event of first failure for the patient, the operator or third parties, must follow the periodically checks, the level of effective safety.
  • Page 39: Extraordinary Maintenance

    Before to replace a fuse, is needed find the reason why is blown up , replace the fuse just when the problem has been fixed. The new fuse has to be the technical features as the replaced one, indicated on the electrical diagram of the dental unit. OMS MOON S.T.01/3L ED.2 REV.0 05/2021...
  • Page 40 11 - FUSE chair trasformer 200mAF, 230 AC; 12 - FUSE chiar trasformer 200mAF, 12 Vac; 13 - FUSE trasformer chair PCB, 12 Vac. DANGER The replacement of the fuses must done by an authorized technician O.M. S. OMS MOON S.T.01/3L ED.2 REV.0 05/2021...
  • Page 41: Technical Instructions For Installation

    4. Fix the chair on the floor using the two expansion anchors and screw (supplied). 5. Connect the unit to the electrical network, then place the cover. 6. Connect the ground cables to the screw marked with the earth symbol. 7. Place the headrest and right armrest. OMS MOON S.T.01/3L ED.2 REV.0 05/2021...
  • Page 42: Post Intalllation Check

    Drive the chair lift motor ❑ Driver the backrest motor DANGER The main power switch cut-off the device from the electrical network, Do not make any servicing on the unit while the power switch is on. OMS MOON S.T.01/3L ED.2 REV.0 05/2021...
  • Page 43 Manufacturer's Guide and declaration – Electromagnetic emissions The OMS dental unit is intended for use in the electromagnetic environment below specified. The customer or user of the OMS dental units should assure that it is used in such an environment.
  • Page 44 A should be below the level of compliance for each frequency range B. IEC 61000-4-3 from 80 MHz to 2,5 GHz Interference may occur near devices marked with the following symbol: OMS MOON S.T.01/3L ED.2 REV.0 05/2021...
  • Page 45 NOTE 1: to 80 MHz and 800 MHz, applies the separation distance for the highest frequency range. NOTE 2: These guidelines may not be applied in all situations. Electromagnetic propagation is influenced by the absorption and reflection of structures, objects and people. OMS MOON S.T.01/3L ED.2 REV.0 05/2021...
  • Page 46 The appropriate separate collection for the subsequent start of the equipment disposed of recycling, treatment and environmentally compatible disposal helps to avoid possible negative effects on the environment and health and promotes the reuse and/or recycling of the materials of which the equipment is composed. OMS MOON S.T.01/3L ED.2 REV.0 05/2021...
  • Page 47 Space reserved for the Company (Directorate General) Operational decisions _____________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ Corrective actions ________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ Date ____________________________________ Signature ________________________________ In case of an accident send the form to O.M.S.. with the maximum priority. OMS MOON S.T.01/3L ED.2 REV.0 05/2021...

Table of Contents