WARNING
1. Press the "On/Off" button on the controller to start the unit. The LED display will illuminate, the
combustion fan will begin to run if water is flowing, and the spark will ignite the main burner.
2. This water heater has an automatic ignition system. When the main burner has lit, the "In Use"
lamp will glow red and the spark will stop.
3. Check that the burner flames are operating normally. The flame can be seen through the circular
window above the burner. When operating normally, the burner flame should burn evenly over
the entire surface. The flame should be clear, blue and stable. A yellow flame is abnormal and
maintenance is required (Figure 16).
SATISFACTORY
Figure 16. Satisfactory and Unsatisfactory Burner Flames
4. If the unit operation is normal, turn off the unit by pressing the "On/Off" button and reinstall the
front panel.
CAUTION
5. Enter the required information on the conversion rating plate label (Figure 17).
Figure 17. Required fields on the conversion rating plate label
6. Affix the conversion rating plate label as close as possible to the existing rating plate on the
appliance.
Conversion Manual for Condensing Tankless Water Heaters
Read the section "For Your Safety Read Before Operating" in section "4.4
Operating Instructions" before starting the steps below.
Do not touch the areas at or near the heat exchanger or hot
water lines; these areas become hot and could cause burns.
UNSATISFACTORY
9