Rinnai RE Series Manual page 4

Tankless water heater, gas conversion manual

Advertisement

Model
Gas Consumption (Btu/h)
Gas Supply Pressure
The input rate can be verified by following the procedure in the National Fuel Gas Code (NFPA54 /
ANSI Z223.1, 2006 or latest edition).
The gas manifold is stamped either "LP" for Liquid Propane Gas or "NG" for Natural Gas.
To Gas
Model
Type
REP199i
RE199i
LP
REP199e
RE199e
RE180i
NG
RE180e
REP160i
RE160i
LP
REP160e
RE160e
RE140i
NG
RE140e
1
Kit includes Gas Manifold (gas Specific), gasket (inner and outer), conversion rating plate and
conversion manual.
Screwdriver
Manometer
Conversion Manual for Condensing Tankless Water Heaters
RE199
REP199
Minimum
Maximum
Minimum: 4.0 in. (1.00 kPa) W.C.
Natural Gas
Maximum: 10.5 in. (2.61 kPa) W.C.
Minimum: 8.0 in. (1.99 kPa) W.C.
Propane
Maximum: 13.0 in. (3.24 kPa) W.C.
Kit
Gas Manifold
1
Number
104000308
106000252
104000309
106000253
104000310
106000254
104000311
106000255
RE180
10,400
10,400
199,000
180,000
Conversion Rating Plate
100000780
100000781
100000782
100000783
RE160
RE140
REP160
10,400
10,400
160,000
140,000
Conversion
Manual
100000784
4

Advertisement