Rooftop Supply Mixed Flow Fans
Fans are direct-driven with mixed flow wheels and feature rigid
construction, high efficiency, and low sound levels. These fans
are designed for filtered roof supply applications such as providing
non-tempered make-up air. The fans are available in twelve sizes
and feature permanent, washable aluminum filters.
Units that ship fully assembled: Horizontal intake sizes 7 through 24,
bottom intake sizes 7 through 22
Units that ship with hood knockdown for field assembly: Horizontal intake
sizes 27 through 33, bottom intake sizes 24 through 33
General Safety Information
Only qualified personnel should install this fan.
Personnel should have a clear understanding of these
instructions and should be aware of general safety
precautions. Improper installation can result in electric
shock, possible injury due to coming in contact with
moving parts, as well as other potential hazards. If more
information is needed, contact a licensed professional
engineer before moving forward.
1. Follow all local electrical and safety codes, as well as
the National Electrical Code (NEC) and the National
Fire Protection Agency (NFPA), where applicable.
Follow the Canadian Electric Code (CEC) in Canada.
2. The rotation of the wheel is critical. It must be free
to rotate without striking or rubbing any stationary
objects.
3. Motor must be securely and adequately grounded.
4. Do not spin fan wheel faster than max cataloged fan
RPM. This could cause catastrophic wheel failure.
Adjustments to fan speed significantly affects motor
load. If the fan RPM is changed, the motor current
should be checked to make sure it is not exceeding
the motor nameplate amps.
5. Do not allow the power cable to kink or come in
contact with oil, grease, hot surfaces or chemicals.
Replace cord immediately if damaged.
6. Verify that the power source is compatible with the
equipment.
7. Never open access doors to a duct or fan while the
fan is running.
8. Never remove covers protecting electrical
components while fan is energized.
®
Rooftop Supply Mixed Flow Fans
DANGER
Always disconnect, lock, and tag power source before
installing or servicing. Failure to disconnect power
source can result in fire, shock, or serious injury.
CAUTION
When servicing the fan, motor may be hot enough
to cause pain or injury. Allow motor to cool before
servicing.
DANGER
Pour écarter les risques d'incendie, de choc électrique
ou de blessure grave, veiller à toujours débrancher,
verrouiller et étiqueter la source de courant avant
l'installation ou l'entretien.
ATTENTION
Lors de toute intervention sur la soufflante, le moteur
peut être suffisamment chaud pour provoquer une
douleur voire une blessure. Laisser le moteur refroidir
avant toute maintenance.
Rooftop Supply Mixed Flow Fans
Document 486132
Model KSQ Direct Drive
1

Advertisement

Table of Contents
loading

Summary of Contents for Greenheck KSQ

  • Page 1 Document 486132 Model KSQ Direct Drive Rooftop Supply Mixed Flow Fans ® Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with these instructions will result in voiding of the product warranty and may result in personal injury and/or property damage.
  • Page 2 Receiving Storage Upon receiving the product, check to ensure all items Fans are protected against damage during shipment. If are accounted for by referencing the delivery receipt or the unit cannot be installed and operated immediately, packing list. Inspect each crate or carton for shipping precautions need to be taken to prevent deterioration of damage before accepting delivery.
  • Page 3: Dimensional Data

    Dimensional Data Intake Con gurations Fan Dimensions HORIZONTAL INTAKE BOTTOM INTAKE Horizontal Intake Bottom Intake Max. Fan Size Weight^ Discharge Con gurations 32-1/2 16-3/8 11-3/8 15-1/4 20-3/8 16-3/8 15-1/4 36-1/2 20-7/8 41-3/4 24-1/4 20-7/8 43-1/2 22-1/2 23-1/4 18-1/4 22-1/8 23-1/4 22-1/8 54-3/4 29-1/4...
  • Page 4 Pre Start-Up Checks Before Fan Installation Operation Before starting up or operating fan, check all fasteners IMPORTANT: The fan has been checked for for tightness. In particular, check the cap screws in wheel bushing. mechanical noise at the factory prior to shipment.
  • Page 5: Typical Installation

    Typical Installation NOTE: For units supplied or used with a Variable STEP 3 - Install Ductwork (bottom discharge Frequency Drive (VFD), reference the VFD units only) documentation for installation requirements, start-up • Good duct practices should be followed in settings, parameter adjustments and trouble shooting. accordance with SMACNA and AMCA guidelines, VFDs provided by the manufacturer are factory NFPA 96 and any local codes.
  • Page 6 STEP 7 - Fasten Filter Tracks 2. Install the second hood top panel with the double to Side Panels return flange by hinging it around the first panel as illustrated (reference 2) • Install a 1/4 inch thumb screw in the slot and 3.
  • Page 7 STEP 11 - Install End Caps STEP 13 - Install Side Panels Mating surface • TAKE CARE NOT TO DAMAGE THE FOAM TAPE ON • Install with the drip edge down and align the SIZE 27-33 Bottom THESE PARTS half-moon cutouts on the side panel with the inlet Plug unused and outlet fasteners •...
  • Page 8 STEP 16 - Route Wiring to Junction Box • Sizes 27-33: • Route the wiring from the junction box to the 1. Install the first top panel with the single return disconnect through all conduit flange using the provided self-tapping sheet metal screws (reference 1) ®...
  • Page 9: Parts List

    Parts List Each fan bears a manufacturer’s nameplate with model number and serial number embossed. This information will assist the local representative and the factory in providing service and replacement parts. Before servicing, assure unit is not capable of operation during repairs. Housing Motor Intake Hood...
  • Page 10 Motor Tapered Bushing Hub Motor maintenance is generally limited to cleaning For wheel hubs utilizing a tapered bushing interface, and lubrication (where applicable). Cleaning should be follow this procedure for installation and removal. limited to exterior surfaces only. Removing dust buildup Bushing Removal on motor housing ensures proper motor cooling.
  • Page 11: Maintenance Log

    Maintenance Log Date ___________________Time _____________ AM/PM Date ___________________Time _____________ AM/PM Notes: ___________________________________________ Notes: ___________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ Date ___________________Time _____________ AM/PM Date ___________________Time _____________ AM/PM Notes: ___________________________________________ Notes: ___________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ Date ___________________Time _____________ AM/PM...
  • Page 12: Troubleshooting

    As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice. Product warranties can be found online at Greenheck.com, either on the specific product page or in the literature section of the website at Greenheck.com/Resources/Library/Literature.