Cleaning Instructions - Panasonic WH-ADC0912K9E8 Operating Instructions Manual

Air-to-water hydromodule + tank
Table of Contents

Advertisement

Cleaning instructions

To ensure optimal performance of the system, cleaning has to be carried out at regular intervals.
Consult an authorised dealer.
• Disconnect the power supply before cleaning.
• Do not use benzine, thinner or scouring powder.
• Use only soap (
pH7) or neutral household detergent.
• Do not use water hotter than 40 °C.
Regular Checks
Indoor unit
• Do not splash water directly.
Wipe the unit gently with a soft dry cloth.
Sanitary Water Tank
Water pressure check
• Ensure that the water pressure is between
0.5 bar and 3.0 bar.
• In case the water pressure is out of the
above range, consult an authorised dealer.
• Water pressure can be checked through
following method:-
Go to System check > System information >
Water pressure
Safety relief valve
WH-ADC Hot water heater has two safety valves, one for
the (TANK) and one for the (CIRCUIT).
• The TANK's safety relief valve sometimes releases a
little water after hot water usage. This is because the
cold water, which enters the water heater, expands when
heated, causing the pressure to rise and the safety valve
to open.
• The CIRCUIT's safety relief valve must be completely
closed and must not normally release any water.
• The functioning of the safety relief valve should be
checked regularly. You can fi nd the safety valve behind
the inspection cover on the front.
Perform the checks as follows:
1. Open the valve.
2. Check that water fl ows through the valve.
3. Close the valve.
4. Check the system pressure, top up if required.
48
Water fi lter
• Clean the water fi lter at least once a year. Failure to do
so may cause the fi lter to clog up, which may lead to
system breakdown. Consult an authorised dealer.
• Please also remove dust on the magnet.
Water Filter Set
Outdoor unit
• Do not obstruct the air inlet and outlet vents. Failure
to do so may result in low performance or system
breakdown. Remove any obstruction to assure the
ventilation.
• When it snows, clean and remove snow around the
outdoor unit to prevent the air inlet and outlet vents from
being covered with snow.
Tips: For extended non-use
• The water inside the Tank should be drained.
• Disconnect the power supply.
Info: Non serviceable criteria
Disconnect the power supply
then please consult an authorised dealer under the
following conditions:
• Abnormal noise during operation.
• Water/foreign particles have entered the Remote
Controller.
• Water leaks from the indoor unit.
• Circuit breaker switches off frequently.
• Power cord becomes excessively warm.

Advertisement

Table of Contents
loading

Table of Contents