AND NUMBER
2.Hold-down operation voltage (B+)
* Currentmeter
*FBT (TSO1) Pin
1) Connect the *currentmeter between the *pin of FBT and
the land of it with correct polarity.
*Entirely white
*1760 + SOpA
2) Receive *Signal and adjust the *ABL current to follows
with the PICTURE and the BRIGHTNESS controls.
Connect the *Digital Multimeter to *TP.
* Digital
*TP9I (+B)
Increase the DC power voltage gradually by adjusting the
Multimeter
resister of RV! until the Picture just blanks out.
Read the digital voltmeter indication.
Turn DC power Source off immediately.
*STANDARD
*Less than 140.0 VDC
Receive *Signal and adjust the *ABL current to follows,
* Dot signal
* 160+ SODA
with the PICTURE and the BRIGHTNESS controls.
Repeat steps from 4) to 6).
*STANDARD
*Less than 143.5 VDC
TP91
PM501
ABL T504 FBT
10p1nC)
R511 3
. Hold-down readjustment
:
When step | 1s not satisfied, readjustment should be performed
ammeter
digital
:
:
3m A dc ramge
multimeter
by altering the resistance value of *resistor (a component
*PARSI1
marked with b4) .