Indicators; Front Panel; Bottom Panel - Tektronix A6902B Service Manual

Isolator
Hide thumbs Also See for A6902B:
Table of Contents

Advertisement

Operating Instruc^ons
A6902B
Service
ONNECTORS
AN
Refer
to
Figure 2-5
for
the
location of
items
1
through
5.
Refer
to
Figure
2-6
for
the location
of
items
6
through
9.
NOTE
Only
CHANNEL
2
controls (items
2 through
5)
and
the
POWER
indicator (item
1)
are shown.
CHANNEL
1
controls are identical
to
CHANNEL
2.
(T)
POWER
indicator
is
on whenever
the
Isolator
is
energized.
fe)
POWER
SWITCH
controls
application
of
ac
power
to
the
Isolator.
An
indicator
light
on
the
front
panel
is
actuated
when
the
power
switch
is
in its
"on"
position
(1).
(T)
POWER CONNECTOR/VOLTAGE
SELECTOR
allows the
connection
of
the
ac power
cord
to
the
isolator.
The
connector
is
an lEC
connector,
and
includes the Voltage Selector/indicator
for
alternative
line
voltage,
(fully
discussed
in
the
"Preparation For
Use"
section
of
this
manual.)
VOLTS/DIV
switches
establish the
sensitivity
of
the
oscilloscop>e/lsolator
system.
The
sensitivity
is
adju-
stable
from
20
mV/divis«on to
500
V/division
in
a
1
2,
and 5 sequence.
OUTPUT VOLTAGE
connectors
make
available
the
output
of Isolator
Channels
1
and
2.
ZERO ADJ
controls
are
used
for
adjusting the
output
dc
level
to zero
volts
with zero
volts Input to
the
A6902B.
7)
AC-COMMON-DC
switches
select the
coupling
^
between
the
input
probe and
the input
stage
of
the
Isolator.
In
DC,
the input
is
directly
coupled:
in
AC
the
input
is
connected
to
the
isolator
through a capacitor;
and
in
COMMON
the input
is
connected
to
the electronic
circuitry
Common
terminal within
the
Isolator,
(COMMON
is
com-
parable
to
the
GND
position
on
a
conventional
oscilloscope.
It
connects
the input
to
a
refer-
ence
level
so
the
operator can
set the position
control).
CAUTION
label
provides fuse replacement and
line
voltage information.
@
EARTH-GROUND CONNECTION
is
a
standard
banana-plug
connector
attached
to
the
Isolator
chassis ground.
BOTTOM
PANEL
(7^ CAUTION
label
warns
operators
not
to
open
the
A6902B
case.
Refer
to
Figure
2-6
for
the
location of item
1
1
PROBE
COMP
controls are
used
to
compensate
the
input
stages
of the
isolator
when
the
input
probes
are
changed.
Refer
to
Figure 2-6
for
the
location
of
items
6
through
10.
CAUTION
label
warns
operators
not to
open
the
A6902B
case.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the A6902B and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents