Download Print this page

Panasonic SF2C-H Series Quick Instruction Manual page 4

Light curtain / type 2

Advertisement

7
OPERATION OF INDICATORS
Normal Operation
Indicators
Device status
Emitter
Before power is ON
After power is ON
Light received status
(all beams received)
After power is ON
Light blocked status
One or more beams blocked
When an error occurs
Blinks in yellow,
Blinks in orange,
Indicators (Note)
Setting procedure and check
items
Emitter
Normal state
Emitter
abnormal
Error state
Receiver
abnormal
8
FUNCTION
Refer "our web site (http://panasonic.net/id/pidsx/global)" for details of func-
tions of this product.
9
MAINTENANCE
<Reference>
When any errors are found, refer to "our web site (http://panasonic.net/id/pidsx/
global)" and report the symptoms to the maintenance in charge. If the recti cation
method is not clear, please contact our of ce.
Please make a copy of this checklist, check each inspection item in the respective
square, and le the list for record.
Daily Inspection
WARNING
Be sure to inspect the following items prior to operation and con rm that there is no
error. Operating this device without inspection or in an error condition can result in
death or serious injury.
Check column
Dangerous parts of the machine cannot be reached without passing through the sensing area of this
device.
Some part of operator's body remains in the sensing area when operation is done with dangerous
parts of the machine.
The calculated safety distance has been maintained or exceeded during installation.
There is no damage to the safety guard or protective structure.
There is no defect, fold, or damage in the wiring.
The corresponding connectors have been connected securely.
No dirt or scratches exist on the light emitting surface.
The test rod is not deformed or defective.
The operation indicator (green) of the emitter and the OSSD indicator (green) of the receiver light up
when no object is present in the sensing area.
The control output (OSSD) shall be ON. At this time, the effect of external noise can be inspected. In
case external noise affects the operation, remove its cause and reinspect.
Move the test rod (ø25mm) up and down 1,600 mm/sec. or less at three positions, just in front of the
emitter, between the emitter and receiver and just in front of the receiver.
The OSSD indicator (red) of the receiver and the operation indicator (red) of the emitter continue to
light up as long as the test rod is present in the sensing area.
With the machine in the operating condition, the dangerous parts operate normally when no object is
present in the sensing area.
With the machine in the operating condition, the dangerous parts stop immediately when the test rod
(ø25mm) is inserted into the sensing area at any of the three positions, directly in front of the emitter,
midway between the emitter and the receiver, and directly in front of the receiver.
The dangerous parts remain stopped as long as the test rod is present in the sensing area.
The dangerous parts stop immediately when the power supply of this device is turned OFF.
The control output (OSSD) must turn OFF when the test input wire (pink) is open (PNP output type
connected to +V, NPN output type connected to 0V). At this time, the effect of external noise can be
inspected. In case external noise affects the operation, remove its cause and reinspect.
Ramco Innovations
Lights up in red,
Lights up in green,
Turns OFF
Control output
Lockout output
(OSSD)
(SSD)
Receiver
OFF
OFF
ON
ON
OFF
ON
Lights up in red,
Lights up in green,
Turns OFF
Control output
Lockout output
(OSSD)
(SSD)
Receiver
ON
ON
OFF
OFF
OFF
OFF
Inspection item
www.PanasonicSensors.com
Periodic Inspection (Every Six Months)
WARNING
Be sure to inspect the following items every six months and con rm that there is no
error. Operating this device without inspection or in an error condition can result in
death or serious injury.
Check column
The structure of the machine does not obstruct any safety mechanism for stopping operation.
No modi cation has been made in the machine controls which obstructs the safety mechanisms.
The output of this device is correctly detected.
The wiring from this device is correct.
The overall response time of the complete machine is equal or less than the calculated value.
The actual number of operation cycle (time) of the limited lifetime parts (relay, etc.) is less than their
rated operation cycles (time).
No screws or connectors of this device are loose.
No extraneous light source or re ective object has been added near this device.
Inspection after Maintenance
1. When any parts of this device are replaced.
2. When some abnormality is felt during operation.
3. When beam-axis alignment of the emitter and receiver is done.
4. When the device installation place or environment is changed.
5. When the wiring method or wiring layout is changed.
6. When FSD (Final Switching Device) parts are replaced.
7. When FSD (Final Switching Device) setting is changed.
10
SPECIFICATIONS
Type
Model No.
Number of beam channels
Protective hight
160 (8 channels) to 640 (32 channels) mm
Sensing range
Minimum sensing object
Supply voltage
Maximum source (PNP) / sink (NPN) current 200mA, Residual voltage 2.5V or less
Control output (OSSD)
Leakage current 200 A or less, Maximum load capacity 2.2 F, Load wiring resistance 3 or less
Response time
When OFF 20ms or less, When ON 80 to 100ms
Maximum source (PNP) / sink (NPN) current 60mA, Residual voltage 2.5V or less
Lockout output (SSD)
Leakage current 200 A or less, Maximum load capacity 2.2 F, Load wiring resistance 3 or less
Ambient temperature
Ambient humidity
11
CE MARKING DECLARATION OF CONFORMITY
Itemized Essentials of EU Declaration of Conformity
Manufacturer's Name: Panasonic Industrial Devices SUNX Co., Ltd.
Manufacturer's Address: 2431-1, Ushiyama-cho, Kasugai, Aichi 486-0901, Japan
EU Representative's Name: Panasonic Marketing Europe GmbH Panasonic Testing Center
EU Representative's Address: Winsbergring 15, 22525 Hamburg,Germany
Product: Active Opto-electronic Protective Device (Light Curtain)
Model Name: SF2C Series
Trade Name: Panasonic
Application of Council Directive:
- 2006/42/EC Machinery Directive
- 2004/108/EC EMC Directive (Valid until April 19, 2016)
- 2014/30/EU EMC Directive (Valid from April 20, 2016)
- 2011/65/EU RoHS Directive
Harmonized standards:
- EN 61496-1 2013
- EN ISO 13849-1 2008
- EN 55011 2009+A1 2010
- EN 61000-6-2 2005
- EN 50581 2012
Type Examination: Certi ed by TÜV SÜD Product Service GmbH Ridlerstrasse
65 80339 München Germany
© Panasonic Industrial Devices SUNX Co., Ltd. 2016
http //panasonic.net/id/pidsx/global
Overseas Sales Division (Head Of ce)
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone +81-568-33-7861 FAX +81-568-33-8591
(800) 280-6933
Inspection item
20mm pitch type
SF2C-
8 / 12/ /16 / 20 / 24 / 28 / 32
0.1 to 3m
ø25mm opaque object
24V DC ±20%
-10 to +55°C, Storage -25 to +60°C
30 to 85%RH, Strage 30 to 85%RH