4.2 Floating Load
The floating load configuration is useful for achieving higher peak-to-peak voltage swings. The connection
diagram is illustrated below.
probe.
The desired output voltage range can be selected from the following table.
5 Input Connection Diagram
The front panel input connector is an industry standard DB37 Female Connector (TE 1658612-1). Any Male
DB-37 cable plug is compatible. The connection diagram is illustrated below.
Digital disable command
PD32 V4 Manual
Do not connect either of these signals to ground, for example, an oscilloscope
In1
20
Min Voltage
Max Voltage
-130
-95
Floating Load Voltage Ranges
Signals
Analog Inputs 1 to 32
Ground
Non Connected
Overload indicator
Input Connector Signals
Input Connector Pinout
Out1+
+
Piezo 1
Out1-
Order Code
+130
PD32-130,130
+95
PD32-95,95
Input Connector
Pins 1 to 32
33, 34
35
Pin 36
3.3V or 5V logic
Pin 37
6
Notes
+/- 10V max
5V logic
15/02/2024