Electrical equipment of machines IEC 60204-1:1997 General requirements Limitations to use Heavy industrial equipment It is declared for and on behalf of Proton Products Ltd that the equipment specified below conforms to these EC directives: 2004/108/EC Electromagnetic compatibility directive Conforms to EC directives...
20kW wire preheater (400V/480V AC 3-phase supply PH300-20-400/480-MKII 00008MC080 voltage) 12kW wire preheater (480V AC 3-phase supply PH300-12-480/480HS-MKII 00008MC851 voltage) 25kW wire preheater (400/480V AC 3-phase supply PH300-25-400/480-MKII 00008MC590 voltage) Page 5 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
Page 6
Proton Products International Limited 10 Aylesbury End Beaconsfield Bucks HP9 1LW ENGLAND Proton Products is an ISO9001:2015 registered company. The declaration is signed by: Paul Sives ……………………… Page 6 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
NTRODUCTION The Proton Products PH300 series MKII wire preheaters are designed for use on continuous cable production lines for the preheating of bare solid and stranded wire prior to the application of extruded insulation. Wire preheating prior to insulation extrusion aids in the adhesion of the insulation to the wire.
0 to +10V temperature control input, user scalable Control(FB) Temperature input 0 to +10V temperature feedback input, user scalable Communications interfaces CAN-bus; I-BUS; RS-232/485; Ethernet Page 8 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
• Sensitive electronic equipment such as personal computers, wrist watches or magnetic media must not be located near the unit. Page 14 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
(not fitted) should be used. This is a single pulley of 300mm diameter fitted to a special back plate (spill ring). This should be fitted if the wire size is above 1.2mm (1mm Page 15 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
Page 16
Attach the pulley plate to the preheater using the indicated fixings. Quantity Part name Type Hex socket head cap M5× 20 screw Spring washer Ø5 Flat washer Ø5 Page 16 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
Page 17
Attach the mounting plate to the preheater using the indicated fixings. Quantity Part name Type Hex socket head cap M5× 16 screw Spring washer Ø5 Flat washer Ø5 Page 17 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
PH300-20-400/480-MKII 16mm² for 70℃ PVC or 10mm²for 90℃ PH300-20-400/480HS-MKII 16mm² for 70℃ PVC or 10mm²for 90℃ PH300-25-400/480-MKII 25mm² for 70℃ PVC or 16mm²for 90℃ Page 18 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
Page 19
2. Insert wire and withdraw the 2. Insert wire and withdraw the screwdriver to clamp the wire. screwdriver to clamp the wire. Replace the cover plate and 6 screws. Page 19 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
LEDs status indicators for CAN-bus, power, I-BUS and Ethernet are located in this junction box. • For information on connecting communications and electrical interfaces, please refer to the relevant sections of this manual. Page 20 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
Preheating switch button / ON Flash Preheater is ready for preheating. Preheating stopped Preheating switch button / OFF Flash Preheater is in fault condition. Page 21 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
Measured loop voltage as a percentage of the maximum loop 0~999.9% voltage. Measured loop current as a percentage of the maximum loop 0~999.9% current. 0~9999 Measured line speed. Page 22 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
Page 23
Press the button to go to the function menu page. Press the button to advance to next Preset page for wire material setting. Page 23 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
Page 24
Enter the resistivity of the special material. Density Enter the density of the special material. Specific heat Enter the specific heat of the special material. Page 24 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
FUNCTION MENU Press the Home icon to return to the home page; or press the other icons to access the respective configuration pages. Page 25 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
For low line speeds, it is likely that the wire is cooler than the “Set temperature” even with a large “Tuning gain” value; hence it is recommended that the “Tuning zero” value be adjusted for temperature compensation at low line speeds. Page 26 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
Page 27
On a high speed line, do NOT set this value too high as the sudden tension change as preheating commences may result in wire breakage. Page 27 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
Page 28
System page 3 to advance to System page 4. This Group setting page can also be accessed by clicking on the home page. Page 28 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
Page 29
OFF state before changing the active group number. Note 2: When the Group authority was set to “Locked” on the Access level page, only “Recall” operation can be executed. Page 29 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
Page 30
System page 5 to advance to System page 6, 7. These two pages are used to display the system information of the preheater. Page 30 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
Select the RS422 baud rate from options: 4800; 9600; 19200; 38400; 115200. Press the button on Communication page 2 to advance to Communication page 3. Page 31 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
Enable the DHCP allocation of the i-BUS IP address. INTERFACE Press the Interface icon on the function menu page to access Interface page 1 and 2 for the analogue output configuration. Page 32 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
Page 33
Set the temperature control full scale value (only if “External Analogue” Temp control full scale is selected above.) Press the button to advance to Interface page 4 and 5 for relay configuration. Page 33 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
Set the ambient temperature value at which the relay operates. ACCESS LEVELS Press the Access levels icon on the function menu page to enter Access levels page. Page 34 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
Page 35
Access level restrictions only apply to settings made on the interface display unit. Adjustment of parameters via RS-232 or optional I-BUS communications interfaces are not subject to access level restrictions. Page 35 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
In the absence of electrical power, the doors may be unlocked by applying the following procedure: Unscrew the 4 fixing screws securing the lower rear door of the preheater: Page 36 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
Page 37
Open the lower rear door, locate the lock override holes and unscrew the black plastic blanking plugs: Page 37 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
Page 38
Insert the unlock tool into the hole until it is engaged and rotate the tool 180° to UNLOCK the doors: Page 38 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
Page 39
Page 39 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
Page 40
Insert the unlock tool into the hole until it is engaged and rotate the tool 180° to LOCK the doors: Page 40 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
CAUTION: The rim of this pulley may be hot; wear heat resistant gloves. Run the wire horizontally out through the wire outlet port. Wire threading for two pulleys: Core Core Core Core Page 41 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
Page 42
The maximum wire drag / tension increase is less than 1N. After threading the wire, close the door and turn the door handle clockwise until it is vertical to latch the door closed. Page 42 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
OFF preheating. Note: The solenoid door will be unlocked when the preheating is switched off. Do not open the door until the pulleys become stationary. Page 43 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
The solenoid door lock is Contact your Proton Products unable to lock the door service representative. handle. Door open. Close the door. Page 44 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
Page 45
Inspect mains power supply Mains power supply phase for phase loss and remedy loss. accordingly. Coupling capacitor voltage at Contact your Proton Products maximum value. service representative. Page 45 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
This CAN-bus interface is fitted as standard. It operates independently of the other communication interfaces and may be used at the same time as them. The CAN-bus interface uses a proprietary Proton Products protocol. It is exclusively used to communicate between the unit and other Proton Products modules. The unit automatically detects connection to other modules and configures the bus appropriately;...
Extinguished No communication For detailed information regarding I-bus configuration, please refer to the supplementary manual “PLC configuration with gauges fitted with Profibus, profinet, EIP”. Page 47 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
300pF per metre, the maximum recommended baud rates are as follows: Cable length range / m Maximum baud rate / s 115200 38400 19200 9600 4800 Page 48 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
LED status Indication Continuous green Online and connected Ethernet communications Flashing green Online but not connected Continuous red Critical link failure Flashing red Connection timeout Page 49 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
Locked Ground reference Not isolated from earth. Electrical specifications Specification Minimum Typical Maximum Units Door solenoid unlock voltage Ω Solenoid coil resistance Page 50 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
Electrical specifications Specification Minimum Typical Maximum Units LOW state input voltage HIGH state input voltage Absolute input voltage kΩ Input impedance Page 51 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
Page 52
The STOP input is driven LOW or disconnected by an external contact to stop the preheater. • The front panel keys are disabled by this connection. Page 52 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
• Analogue outputs 1, 2, 3 and 4 are short circuit proof. Specification Minimum Typical Maximum Units Output voltage Output-to-earth voltage kΩ Load resistance Page 53 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
AC voltage between contacts V (rms) DC voltage between contacts Contact-to-earth voltage Current Ω On resistance (at a current of 100mA) MΩ Off resistance Page 55 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
Specification Minimum Typical Maximum Units Analogue input voltage measurement range (referenced to SET TEMP-). Analogue input voltage absolute range kΩ Input impedance Page 56 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
Specification Minimum Typical Maximum Units Analogue input voltage measurement range (referenced to FB TEMP-). Analogue input voltage absolute range kΩ Input impedance Page 57 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
ODBUS PARAMETER ACCESS PROTOCOL This protocol provides access to individual parameters or blocks of parameters and is typically used in a production environment where the Proton Products instrument is connected to a computer, Modbus connected PLC or similar device. The parameters consist of 16-bit words (DW) and are divided into input and output groups: •...
Heating State Relay 1=1% 0~99% Operation Threshold Relay 0=Fault; Relay 1 Function 1=Heating State; 2=Switch State; 3=Emergency Stop; 4=Ambient Temprerature too Relay 2 Function high Page 64 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
Page 65
Density of special 1=0.001grams/cc 0~9.999grams/cc 8900 material 2 Specific heat of 1=0.001cal/g/°C 0~9.999cal/g/°C special material 2 Parameter Group 1~50; 0 is not used Number Page 65 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
Page 66
Subnet Mask 5.255.255.0) C0A80101(19 iBus Gateway 2.168.1.1) UDP Interval Time Destination IP Port number fixed address for UDP to 1111 (last section only) Page 66 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
Page 67
Comments Unit Range/Remark Default Value MAC address for Ethernet Page 67 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
0=OK,1=Wire Broken Parameter setting is wrong 0=OK,1=wrong Ambient temperature too high 0=OK,1=Too high Minior Over Current 0=OK,1=Error Major Over Current 0=OK,1=Error Phase imbalance 0=OK;1=Error Page 68 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
Page 69
Range 4 Wire Size 0.000~99.000 0=NONE; 1=PROFIBUS; i-Bus Type 2=PROFINET; 3=EtherNet/IP Reserved EIP address xx.xx.xx.xx Sub net Mask xx.xx.xx.xx Gateway xx.xx.xx.xx iBUS IP address xx.xx.xx.xx Page 69 of 70 Proton Products PH300 Series MKII Wire Preheater Instruction Manual - Issue 6a...
Proton Products is not responsible for consequential or incidental damage related to the provision or use of the information contained in this manual. • The information contained in this manual is the property of Proton Products and may not be circulated or distributed to third parties. •...