SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and
other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
Installation and service of luminaires should be performed by a qualified licensed electrician.
Maintenance of the luminaires should be performed by person(s) familiar with the luminaires' construction and operation
and any hazards involved. Regular fixture maintenance programs are recommended.
It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient
dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm
water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly
become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.
DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been
damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency
to meet in connection with installation, operation, or maintenance. Should further information be desired or should
particular problems arise which are not covered sufficiently for the purchaser's or owner's purposes, this matter should be
referred to Acuity Brands Lighting, Inc.
WARNING
RISK OF ELECTRIC SHOCK
 Disconnect or turn off power before
installation or servicing.
 Verify that supply voltage is correct by
comparing it with the luminaire label
information.
 Make all electrical and grounded
connections in accordance with the National
Electrical Code (NEC) and any applicable
local code requirements.
 All wiring connections should be capped
with UL approved recognized wire
connectors.
CAUTION
RISK OF INJURY
 Wear gloves and safety glasses at all times
when removing luminaire from carton,
installing, servicing or performing
maintenance.
 Avoid direct eye exposure to the light source
while it is on.
LED IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
WARNING
RISK OF BURN
 Allow lamp/fixture to cool before handling.
Do not touch enclosure or light source.
 Do not exceed maximum wattage marked on
luminaire label.
 Follow all manufacturer's warnings,
recommendations and restrictions for: driver
type, burning position, mounting
locations/methods, replacement and
recycling.
CAUTION
RISK OF FIRE
 Keep combustible and other materials that
can burn, away from lamp/lens.
 Do not operate in close proximity to persons,
combustible materials or substances
affected by heat or drying.
IM-476

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Riverfront III LED RFUE and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Acuity Brands Lighting Riverfront III LED RFUE

  • Page 1 Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc. WARNING...
  • Page 2 Winona Lighting Synergy Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products. ABL LED General Warnings, Form No. 503.203 © 2011 Acuity Brands Lighting, Inc. All rights reserved. 3/15/11...
  • Page 3: Installation

    HOLOPHANE ® Installation and Riverfront ® III LED Maintenance RFUE Manual MS housing GR3001 2. INSTALLATION 1. INTRODUCTION 2.1 Tools and Material Required. 1.1 Product Description. Table 1. Installation Tools and Materials DESCRIPTION This post top luminaire is designed with LED’s which have a long-life expectancy.
  • Page 4 Figure 1 Figure 2 TERMINAL BLOCK PHOTOCONTROL RECEPTACLE DRIVER WIRE TIE MODULE SET SCREWS (6) POLE FITTER GR1862 2.2 Luminaire Installation. 2.2.1 This luminaire is designed to be installed on a bracket or a pole top with a 3” tenon fitter. A latched door on the side of the housing allows access to the driver module and electrical connections.
  • Page 5: Maintenance

    GR1033 3. MAINTENANCE GR1864 3.2.4 To remove surge protector, disconnect quick disconnect plug 3.1 Cleaning coming from terminal and quick disconnect going to optical compartment. Remove (2) screws connecting driver bracket to door; 3.1.1. retain screws for re-installation. Disconnect surge protector via quick Make sure the unit is de-energized.
  • Page 6: Limited Warranty And Limitation Of Liability

    3.2.5 To remove driver module, disconnect quick disconnect plug coming from terminal and quick disconnect going to optical compartment. Remove (2) screws connecting driver bracket to door, retain screws for re-installation. Reinstall new driver module in door. Reconnect quick disconnect plugs from terminal block and quick disconnect plug going to optical compartment.
  • Page 7 % Lumens % Wattage 8 - default 100% 100% ® Acuity Brands Lighting, Inc. 3825 Columbus Rd SW, Granville, OH 43023 IM-466, 6/23/2016 Acuity Brands Lighting Inc., All Rights Reserved Visit our web site at www.holophane.com Printed in USA IM-476...