SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and
other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
Installation and service of luminaires should be performed by a qualified licensed electrician.
Maintenance of the luminaires should be performed by person(s) familiar with the luminaires' construction and operation
and any hazards involved. Regular fixture maintenance programs are recommended.
It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient
dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm
water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly
become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.
DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been
damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency
to meet in connection with installation, operation, or maintenance. Should further information be desired or should
particular problems arise which are not covered sufficiently for the purchaser's or owner's purposes, this matter should be
referred to Acuity Brands Lighting, Inc.
RISK OF ELECTRIC SHOCK
 Disconnect or turn off power before
installation or servicing.
 Verify that supply voltage is correct by
comparing it with the luminaire label
information.
 Make all electrical and grounded
connections in accordance with the National
Electrical Code (NEC) and any applicable
local code requirements.
 All wiring connections should be capped
with UL approved recognized wire
connectors.
RISK OF INJURY
 Wear gloves and safety glasses at all times
when removing luminaire from carton,
installing, servicing or performing
maintenance.
 Avoid direct eye exposure to the light source
while it is on.
CPHB DRIVER REPLACEMENT IMPORTANT SAFETY
READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
WARNING
CAUTION
INSTRUCTIONS
WARNING
RISK OF BURN
 Allow lamp/fixture to cool before handling.
Do not touch enclosure or light source.
 Do not exceed maximum wattage marked on
luminaire label.
 Follow all manufacturer's warnings,
recommendations and restrictions for: driver
type, burning position, mounting
locations/methods, replacement and
recycling.
CAUTION
RISK OF FIRE
 Keep combustible and other materials that
can burn, away from lamp/lens.
 Do not operate in close proximity to persons,
combustible materials or substances
affected by heat or drying.
912-00271-001 Rev A, 04/2021
Page 1 of 5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CPHB and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Acuity Brands Lighting CPHB

  • Page 1 CPHB DRIVER REPLACEMENT IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and •...
  • Page 2 Winona Lighting Synergy Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products. ABL LED General Warnings, Form No. 503.203 © 2010, 2016 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10...
  • Page 3 CPHB DRIVER REPLACEMENT IMPORTANT SAFETY INSTRUCTIONS Protect yourself. Before replacing, read these instructions carefully and save them for future reference. Date Repaired:________________ KIT PACKING LIST Size Lumens Driver Lever Nuts Screws 9000LM 12000LM 15000LM 18000LM 24000LM 30000LM 36000LM 48000LM 60000LM...
  • Page 4 1. Turn off electricity at fuse or circuit breaker box. 2. Disconnect CPHB high bay from power supply. 3. Remove the CPHB high bay from the mounting location and place it in a convenient location to perform the replacement. Check that all parts (including mounting hardware) are accounted for.
  • Page 5 CPHB DRIVER REPLACEMENT IMPORTANT SAFETY INSTRUCTIONS FIGURE 3: INTERNAL VIEW INITIAL DRIVER 9000LM-15000LM REPLACEMENT DRIVER DRIVER SCREW 18000LM PLACEMENT If two drivers were replaced with one driver, DRIVER SCREW 24000LM-30000LM ensure that all incoming PLACEMENT LED leads connect to the corresponding leads on the driver.

Table of Contents