Part 3: Install M9 panel nut to secure the encoder
(1) M9 Panel Nut (green) (Bag 20)
STEP 18: TEST POWER TO THE PCB STACK
https://youtu.be/LngRwWWeiq0
(1) 50mm 40-Position Ribbon Cable (Bag 8)
(2) M4 x 6mm Flat Head Black Oxide Screw (Bag 2)
Do not install the MCU module yet - you will test power first without it.
Connect the 40-position ribbon cable (CN11) between the mainboard and voice motherboard.. This provides
+3.3V, +/-15V, and 5V USB power to the PCB stack.
Make sure the unit is unplugged.
Temporarily disconnect the power switch by removing the two quick connect terminals.
Attach the power switch into the front panel.
Reattach the two power switch wires by feeding them through the hole in mainboard & panelboard.
Mount the front panel to the right side of the enclosure to temporarily secure in place. It's best to leave the left-
side panel uninstalled at this time as there is more testing to do and it will get in the way.
Plug in the unit and turn on the power switch.
Test +3.3V, +5VD, +15V and -15V using the test point on the Voice Motherboard. If ok proceed to the next
steps.
STEP 19: TEST POWER TO THE OUTPUT BOARD
https://youtu.be/B2c_dBbDODc
(1) 50mm 20-Position Ribbon Cable (Bag 8)
(1) 50mm 16-Position Ribbon Cable (Bag 8)
Power off the VS-1
Plug in CN17 & CN17
Power on the VS-1
Verify +15V & -15V on the Voice Motherboard is still good.