Fuji Electric OPC-VG7-SI Instruction Manual
Fuji Electric OPC-VG7-SI Instruction Manual

Fuji Electric OPC-VG7-SI Instruction Manual

Pwm converter optical link option for parallel system

Advertisement

Quick Links

Instruction Manual
Optical Link Option for Parallel System
OPC-VG7-SI
■ If you purchase this product and ship a device or a control panel with a converter integrated with this product,
make sure to provide the end user who actually uses this product with the instruction manual.
■ The information in this instruction manual is subject to change for product improvement.
Fuji Electric Co., Ltd.
INR-HF52179-E

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OPC-VG7-SI and is the answer not in the manual?

Questions and answers

Summary of Contents for Fuji Electric OPC-VG7-SI

  • Page 1 ■ If you purchase this product and ship a device or a control panel with a converter integrated with this product, make sure to provide the end user who actually uses this product with the instruction manual. ■ The information in this instruction manual is subject to change for product improvement. Fuji Electric Co., Ltd. INR-HF52179-E...
  • Page 2: Introduction

    Introduction We thank you for your purchasing our PWM Converter RHC-C Parallel System Optical Link Option “OPC-VG7-SI”. This instruction manual is designed to use when driving the main circuit insulated parallel system accompanying the insulation transformer. You can use OPC-VG7-SI with the converter units of standard specifications.
  • Page 3: Table Of Contents

    Table of contents Introduction ................................1 Safety Instructions ..............................1 Optical Option for Parallel System without Insulation-transformer ............. 3 1 Product Introduction ............................3 1.1 Product Overview ..........................3 1.2 Product Guarantee ..........................4 1.3 Specification of Parallel System ......................4 1.4 Main Circuit Insulated Parallel System Specifications .................
  • Page 4: Optical Option For Parallel System Without Insulation-Transformer

    Optical Option for Parallel System without Insulation-transformer 1 Product Introduction 1.1 Product Overview Driving of high capacity converter The PWM Converter RHC-C Main Circuit Insulated Parallel System drives converters through the accompanied insulation transformer, by connecting multiple converter units (two or three) with the primary power supply insulated. This option unit is best fit to divide load of the connected converters.
  • Page 5: Product Guarantee

    1.2 Product Guarantee The product guarantee period is either twelve months after your purchase or eighteen months after production date displayed on the name plate whichever comes first. The following cases require paid service even during this guarantee period. •Incorrect operation or improper repairing or alteration •Operation out of the standard specification •Drop or damage in shipment after purchase •Earthquake, fire, wind and flood, lightening, abnormal voltage, and other natural disasters or the secondary...
  • Page 6: Main Circuit Insulated Parallel System Specifications

    Item Specification Setting of Sets the application of the option. parallel Setting for parallel system is "SW2-1=ON and SW2-2=OFF". system Hardware Hardware switch of the option SW1 setting Station number SW1=0: Master setting SW1≠0: Slave. Usually set slave 1 to "1", slave 2 to "2", and so on. You can switch single drive and parallel system by setting function code H12 ”Parallel system”...
  • Page 7: External Dimensions

    2 External Dimensions 3-φ3.6 15.4 11.5 Unit:mm Fig. 2.1 External dimensions of optional print circuit board Set the station number switch to master/slave and set the function selection switch to the following fixed setting (parallel system). Fig. 2.2 Station number switch (SW1) Fig.
  • Page 8: Inspection On Arrival

    When your product arrives, check the following items. (1) Check if the product you have is the product you ordered. See the type printed on this option. Description of model; OPC-VG7-SI *This product is common with vector inverter VG7S. Name of option;SI → Optical option card for parallel system parallel system optical link option card.
  • Page 9: Permanent Storage

    4.2 Permanent Storage The method for storing the option over a long period after purchase due to no schedule of operation varies according to the environment of the storage site. If strict storage is necessary, specify the concrete environment specification and contact the dealer or nearest Fuji's sales office. The general storing method is described below.
  • Page 10: How To Install

    5.2 How to Install •Turn OFF the breaker on the power supply side of the converter before you mount/dismount this option. • When the breaker is OFF, a smoothing capacitor is still charged and touching it will cause an CAUTION electric shock.
  • Page 11 B.How to install the Communication Option Following restrictions are applied to installing this option. ♦ Install this option card in either of two installation positions (CN2 on the left side or CN3 on the right side) on the control board while referring to "(a) Installation Method 1-1" described below. However, if an analog card is installed on the same control board, be sure to install the option card at CN2 and install the analog card at CN3.
  • Page 12: Connection

    6 Connection See the Instruction manual (INR-HF51746*-E) of the converter for mounting/dismounting the front cover ▪Improper wiring operation causes disasters such as electric shock and fire. A specialist should conduct the wiring. Turn OFF the breaker on the power supply side when you touch the electric circuit for wiring operation after power is supplied.
  • Page 13: Connecting Optical Fiber Cables

    When installing the option unit, take due consideration on light shielding, for example, storage into a control board. Use the optical fiber cable included in the converter to connect the OPC-VG7-SI card on the individual converters. The optical fiber cable has plugs in different colors, gray and blue on each side. Connect them to the connectors with the same colors on the individual cards.
  • Page 14: Switching Parallel System Driving/ Single Driving

    You can use the external digital input signal [OPT-DI] to cancel parallel system operating with high-speed serial card ”OPC-VG7-SI”, and then it could be changed single system by 1 unit driving. It uses as an urgent backup to decrease the load only with the normal converter when the converter that composes parallel system breaks down and to continue driving.
  • Page 15: Alarm Display Of Parallel System

    6.4 Alarm Display of Parallel System When a converter unit at parallel system issues the alarm, all units enter into an alarm state, and stop. Same alarm code of the first alarm factor is displayed to LED on the keypad panel at the same time. The unit where the alarm is issued can be discerned by the displayed alarm code.
  • Page 16: Basic Wiring Diagram

    6.6 Basic Wiring Diagram The following figure shows a basic wiring diagram (3 units system). Fig. 6.6.1 Special notes 1. When the alarm is issued in the parallel system, Operation command Operaton command MASTER SLAVE 1 SLAVE 2 all units become alarm states (30X is activated), of converter of inverter at the same time, however turn off the RUN...
  • Page 17: Preparation For Operation

    7 Preparation for Operation ・Check the following items before you turn on after you have installed, wired, and set switches. (1) No wiring errors (2) No wire chips or screws left CAUTION (3) No loose screws and terminals (4) No contact of core wires from crimped terminals to neighboring terminals (5) No setting error for SW1 and SW2 See “Section 4 Preparation for Operation”...
  • Page 18: How To Operate

    8.3 How to Operate ・Input driving command 'RUN' to both master and slave. When only the master side or the slave side is given, it doesn't start. Some setting of functions and display on KEYPAD panel in the slave unit are invalid. CAUTION ・When control power is turned ON, it cannot be operate almost 10 seconds for initializing.
  • Page 19: Keypad Panel Function

    8.3.3 KEYPAD panel function Not only master but also slave can be used as a standard product without the restriction. 8.3.4 Function code (F to H) You can use the master as a standard 0; Setting is invalid product except for carrier frequency 1;...
  • Page 20: Optical Network Error(Erb

    9.1 Optical Network Error(Erb) When an optical fiber cable is disconnected or disengaged from a connector, all units become an alarm state due to the optical network error (Erb). If the external alarm condition of the inverter is a converter alarm output, the inverter becomes an alarm state, and the motor stops after coasting You cannot reset the alarm state if you enter a reset command (KEYPAD panel, terminal, communication) while the cause of the alarm is not removed.
  • Page 21: Parallel System Control Block

    Parallel System Control Block The Parallel System is established by transmitting current command data controlled by Master to Slave. L1/R L2/S Ved* L3/T 力率 Power factor 制御 control M ASTER キャリア Carrier 信号 signal Power supply 電源同期 θ synchronous 位相角 phase angle L1/R L2/S...