QUICK START/INSTALL MANUAL
RECLAIM ENERGY/PANASONIC HEAT PUMP HOT WATER SYSTEM
INSTALLATION
OPERATION
MAINTENANCE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Panasonic REHP-KY-CO2-160GL and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Reclaim Panasonic REHP-KY-CO2-160GL

  • Page 1 QUICK START/INSTALL MANUAL RECLAIM ENERGY/PANASONIC HEAT PUMP HOT WATER SYSTEM INSTALLATION OPERATION MAINTENANCE...
  • Page 2 This appliance may deliver water at a high temperature. Refer to the Plumbing Code of Australia (PCA), local requirements and installation instructions to determine if additional delivery temperature control is required. Issue 02 | Feb 2024 Reclaim Energy | Quick Start/Install Manual – v1.0...
  • Page 3: Table Of Contents

    SECTION PAGE First Time Commissioning Procedure Critical Notes System Description Installation Details Before you Begin Installation Installing the Controller Checklist Operation & Maintenance Warning & Caution Quick Start/Install Manual – v2.0 | Reclaim Energy RECLAIMENERGY.COM.AU...
  • Page 4: First Time Commissioning Procedure

    • Check if the water comes out vigorously. (Let it run with a continuous flow for more than a minute). • Do not remove the drain plugs. (For risk of losing them) Reclaim Energy | Quick Start/Install Manual – v2.0...
  • Page 5 “temp” button. The current tank option and active option will be shown within seconds. 3 DRAIN T T A A Ps. Quick Start/Install Manual – v2.0 | Reclaim Energy RECLAIMENERGY.COM.AU...
  • Page 6: Critical Notes

    Hot Outlet: 63c Cold Inlet Heat Pump Flow Port Heat Pump Unit COLD MAINS PLV 500 kPa PLV 500 kPa local plumber - not mandatory from system perspective.) Reclaim Energy | Quick Start/Install Manual – v1.0...
  • Page 7 • Power Supply Terminal Block: L, N, • Supply Cable: 3 Code cable Please note that warranty will be voided if the system is installed without a Reclaim Energy Tank or Reclaim Energy Controller. The system will also be ineligible for any Rebates.
  • Page 8: System Description

    SYSTEM DESCRIPTION The following system description section provides a brief overview of the Reclaim Energy/ Panasonic Heat Pump components and functionality. MAIN COMPONENTS than 15 minutes in duration). When the unit is in the defrost function mode, the pump and fan will stop, and the The system components of the air sourced heat pump that refrigerant heat will defrost the evaporator.
  • Page 9: Installation Details

    Reclaim Energy/Panasonic Heat Pump space should be 100mm. without reading and understanding this installation manual. For any queries Reclaim Energy staff may be • The system requires at least two GPO power outlets contacted on 1300 38 38 15.
  • Page 10 • When transporting boxes, note the orientation of components have been provided. Any concerns must be “THIS WAY UP” arrows. brought to the attention of Reclaim Energy immediately. • Ensure all boxes are strapped and secured to prevent any movement during transit.
  • Page 11 Please note, this is not supplied by Reclaim Energy, the installing plumber can provide advice and consider installing a ring main system for hot water circulation.
  • Page 12 (Top view) Do not apply excessive force. Figure 2: Required space for installation of heat pump. Please note that malfunctions and accidents caused by mounting or transporting will not be covered under warranty. Reclaim Energy | Quick Start/Install Manual – v1.0...
  • Page 13 (The heat pump unit can be installed away from the hot water storage tank) Height difference with the hot water storage tank Quick Start/Install Manual – v1.0 | Reclaim Energy RECLAIMENERGY.COM.AU...
  • Page 14 INSTALLATION DETAILS CONT. 2.3.2 MOUNTING Note: Reclaim Energy ASHP MUST be installed on the • Cold air will blow from the air outlet during operation, ground with mounting frames that is a default supplied avoid installing in locations where the surroundings may be impacted.
  • Page 15 • Use a stand that has an allowable loading mass of 50 that it does not freeze. kg (allowable load of 490 N or more) or more. High Stand 2 Fix the stand’s legs with bolts (4 places) Quick Start/Install Manual – v1.0 | Reclaim Energy RECLAIMENERGY.COM.AU...
  • Page 16 Display Cover for wiring. (1 Screw) (2 Screws) (6 Screws) • All the Piping Cover’s TERMINAL COVER (2 Screws) attachment parts (6 places) should be attached correctly. Reclaim Energy | Quick Start/Install Manual – v1.0 DISPLAY COVER (6 Screws)
  • Page 17 Thermistor Cold Inlet Heat Pump Unit COLD MAINS Figure 9: Plumbing diagram of Reclaim Energy ASHP hot water system. PLV 500 kPa 1 The maximum total distance between the heat pump and tank should not exceed 10m horizontal and 3m vertical.
  • Page 18 Standard 63°c. Special mode 70°c, 75°c, 80°c PLACES USING AN THICKNESS OF THE MATERIALS PIPE LENGTH ELBOW PIPE (ONE WAY) INSULATION MATERIAL Copper Pipes: Φ12.7 Standard: 5m 5 places or less 15mm Maximum: up to 15m Reclaim Energy | Quick Start/Install Manual – v1.0...
  • Page 19 4 Do not join the drain hose with other drainpipes, install it on its own. (Otherwise, it may cause backflow) Please note that malfunctions and accidents caused by piping or drain construction will not be covered under warranty. Quick Start/Install Manual – v1.0 | Reclaim Energy RECLAIMENERGY.COM.AU...
  • Page 20 • Prevent heat loss and freezing by installing insulation material in a way so that the connecting parts are not exposed. Using a torque • Use weather resistant materials for the insulation w rench material. 6 Reclaim Energy | Quick Start/Install Manual – v1.0...
  • Page 21 Storage Tank RJ45 cable (V1.1 controller) Heat Pump Unit Figure 10 Wiring diagram of Reclaim Energy ASHP hot water system. IMPORTANT Do not supply power to the controller or heat pump unit before completing the plumbing and air purge process, as well as the wiring of the heat pump and controller.
  • Page 22 1. The power cable must 2. In this case the power be fixed with metal cable must be fixed also fitting using a pair of the with the Resin wiring screws. clamp using a screw. Reclaim Energy | Quick Start/Install Manual – v1.0...
  • Page 23: Before You Begin Installation

    Remove ALL power sources before removing protective cover. The Reclaim Controller must be installed by a qualifi ed person. Ensure suitable over-current protection and RCD protection for the Reclaim Controller is in place. Quick Start/Install Manual – v1.0 | Reclaim Energy RECLAIMENERGY.COM.AU...
  • Page 24: Installing The Controller

    INSTALLING THE RECLAIM CONTROLLER Mounting Follow these steps: 1. Allow for the enclosure dropping 5mm (1/5 inch) from screw centres once mounted (keyhole mounting). 2. Place the printed drill guide template (that ships with the controller) against the wall, checking for level alignment. All four mounting holes should be used with at least two fi rmly secured into wood or masonry.
  • Page 25 RECLAIM CONTROLLER WITH THE COVER REMOVED Dry contact terminals for option 6 (page 9). Quick Start/Install Manual – v1.0 Quick Start/Install Manual – v1.0 | Reclaim Energy | Reclaim Energy RECLAIMENERGY.COM.AU...
  • Page 26 This is responsibility of customer or installer to have the recommended the heat cycle is activated using the rebate forms ready to fi ll out. boost function. For the Remote Controller, connects to the RJ45 terminal on the PCB display Reclaim Energy | Quick Start/Install Manual – v1.0...
  • Page 27: Checklist

    2 – Sensor cable to tank, 3 – Power is connected. Correct time of day has been set up on the fi rst powering. Controller operational mode (OPTION modes) has been set up with reference to the customer requirements. Quick Start/Install Manual – v1.0 | Reclaim Energy RECLAIMENERGY.COM.AU...
  • Page 28: Operation & Maintenance

    If the heat pump runs outside the settings of the active option, this needs to be escalated to the local service agent and/or Reclaim Energy representative for troubleshooting. There are some possibilities for running outside of the settings of controller such as 1) tank sensor...
  • Page 29 PCB (Main) or HP unit After replacement, still exits same malfunction, replace HPU.” Table 11: Details of error codes on external controller and heat pump PCB display and troubleshooting process CONTINUES ON NEXT PAGE… Quick Start/Install Manual – v1.0 | Reclaim Energy RECLAIMENERGY.COM.AU...
  • Page 30 Check the power voltage. or correct the source of abnormal Power OFF voltage failure voltage. “Replace PCB(Main) PCB(Main) Reset power supply. After replacement, if the same mal- function still exists replace HPU.” Reclaim Energy | Quick Start/Install Manual – v1.0...
  • Page 31 In case of defect, replace expansion failure valve coil” “Replace PCB(Main) PCB (Main) or HP unit Except above mentioned. After replacement, if the same malfunction still exists, replace HPU.” Quick Start/Install Manual – v1.0 | Reclaim Energy RECLAIMENERGY.COM.AU...
  • Page 32 Eg-10 is measured • Boost button is pressed • There was a power up sequence This is a good way of alerting the user if the heat pump is not heating properly Reclaim Energy | Quick Start/Install Manual – v1.0...
  • Page 33 Reclaim system does not require drainage unless the supplied with glass-lined water heater. Where the Total system is left without power or unused for holidays or Dissolved Solids (TDS) is greater than 600mg/L or less maintenance reasons.
  • Page 34: Warning & Caution

    Failure to comply may cause fi re, electric shock, and water leakages) • Use the dedicated earth leakage circuit breaker (RCD) on its own. (When used together with other devices, it may cause a fi re due to heat generation) Reclaim Energy | Quick Start/Install Manual – v1.0...
  • Page 35 (If not adhered to, contact areas between the screw the Reclaim tank and heat pump unit are fully and lath mesh may cause fi res) drained and remain empty until the system is in use.
  • Page 36 1300 383 815 HELLO@RECLAIMENERGY.COM.AU RECLAIMENERGY.COM.AU facebook.com/CO2HeatPump instagram.com/reclaimenergy 20937660(K)