Reclaim Rainmaker 125 Information Manual

W/self cleaning filter

Advertisement

Quick Links

Dec 2011 V1.1
Rainmaker 125
w/Self Cleaning Filter
Information Manual
Maximize your profits with a Water Reclaim System!
Advanced Filtration and Ozone recirculation treatment
th
Reclaim Equipment Company 407 4
Avenue SW New Prague, MN 56071 1-8666-9RECLAIM
www.reclaimequip.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Rainmaker 125 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Reclaim Rainmaker 125

  • Page 1 Dec 2011 V1.1 Rainmaker 125 w/Self Cleaning Filter Information Manual Maximize your profits with a Water Reclaim System! Advanced Filtration and Ozone recirculation treatment Reclaim Equipment Company 407 4 Avenue SW New Prague, MN 56071 1-8666-9RECLAIM www.reclaimequip.com...
  • Page 2 Dec 2011 V1.1 Intentionally left blank ______________________ __________________________________ Reclaim Equipment Company Information Manual...
  • Page 3: Table Of Contents

    6.0 Troubleshooting .............................. 11 7.0 Parts ................................11 Figures and Tables Figure 1: Rainmaker 125 w/Self Cleaning Filter System Overview ............... 1 Figure 2: Rainmaker 125 w/SCF Specifications ..................... 2 Figure 3: Turn-on/Start-up procedure ........................3 Figure 4: Air Purge Valve ............................4 Figure 5: Changing filters ............................
  • Page 4 TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THE UNIT TO RAIN OR MOISTURE. © 2011 Reclaim Equipment Company. All rights reserved. No part of this book, including text, screen examples, diagrams, or images, may be reproduced or transmitted in any form, by any means, without prior written permission of Reclaim Equipment Company.
  • Page 5: Introduction

    1.0 Introduction The Rainmaker 125 is a water recovery system. It is designed to filter water captured in a holding tank and pump it to a storage tank. The water in the storage tank is then continually treated by an ozone recirculation system.
  • Page 6: Figure 2: Rainmaker 125 W/Scf Specifications

    Pump Voltage (VAC) Branch fuse rating (Amps; 3 phase) Control Voltage 115 Vac 1-phase 60 Hz; fuse rating 25 Amps 230 Vac 1-phase 50 Hz; fuse rating 15 Amps Figure 2: Rainmaker 125 w/SCF Specifications ______________________ __________________________________ Reclaim Equipment Company Information Manual...
  • Page 7: Operation

    Make sure the installation complies with the description in section 4.0. Referring to Figure 3: Turn-on/Start-up procedure: Step 1: Open the Supply Valve Step 2: Close the Drain Valve Step 3: Turn on the Primary Pump Step 4: Turn on the Ozone Pump Figure 3: Turn-on/Start-up procedure ______________________ __________________________________ Reclaim Equipment Company Information Manual...
  • Page 8: Cleaning And Filter Change Procedures

    Depending on the level of accumulation in the filters, it may take several minutes to purge the water from the filters. Purging is complete when the drain begins discharging compressed air instead of reclaim water. Figure 4: Air Purge Valve Referring to Figure 5: Step 6: WAIT –...
  • Page 9: Figure 5: Changing Filters

    Replace the lid and evenly hand-tighten the bolts. Step 9: Loosen the Self Cleaning Filter cap. Inspect filter and remove any debris. Retighten cap. Step 10: Close the drain valve (rearmost valve) ______________________ __________________________________ Reclaim Equipment Company Information Manual...
  • Page 10: Figure 6: Changing Filters

    Step 14: Test. To test that the system is operational, activate any device that uses reclaim water. By creating a demand for reclaim, the primary pump will turn on. This confirms that the system is operational. Don’t forget to shut off the test device.
  • Page 11: Installation

    Ozone Injector Vessel lid Exhaust oxygen concentrator Ozone pump Air purge valve Ozone float filter Pressure gauge Air regulator Bladder tank Strainer basket Air filter; oxygen-to- ozone Pressure switch Figure 7: System Components ______________________ __________________________________ Reclaim Equipment Company Information Manual...
  • Page 12: Figure 8: Typical Plumbing Stub-Out

    Dec 2011 V1.1 4.2 Typical installation - plumbing Figure 8: Typical Plumbing Stub-out ______________________ __________________________________ Reclaim Equipment Company Information Manual...
  • Page 13: Figure 9: Typical Electrical Interface (Some Variations Exist)

    400 Vac 3-phase 50 Hz Pump Voltage (VAC) Branch fuse rating (Amps; 3 phase) Control Voltage 115 Vac 1-phase 60 Hz; fuse rating 25 Amps 230 Vac 1-phase 50 Hz; fuse rating 15 Amps ______________________ __________________________________ Reclaim Equipment Company Information Manual...
  • Page 14: Figure 10: Installation Examples

    Dec 2011 V1.1 Tunnel example In bay automatic and self serve example Figure 10: Installation examples ______________________ __________________________________ Reclaim Equipment Company Information Manual...
  • Page 15: Control Cabinet/Ozone Generator Operation

    (Reserved) 6.0 Troubleshooting (Reserved) 7.0 Parts 7.1 Filters The following filters are available from Reclaim. Please contact the company. Refer to Figure 7 herein: Water filter Figure 7 Item 12 Air filter; oxygen-to- ozone Figure 7 Item 16 Ozone float filter Figure 7 Item 22 7.2 Spare parts...
  • Page 16 ALM Canister model 802 PSI 150 Self Cleaning Filter Screen 50 ALM Canister No/Legs 7.3 Component manuals Manuals for various components of the Rainmaker 125 can be found on our website at http://www.reclaimequip.com/ look under RECLAIM RESOURCES >> PRODUCT MATERIALS Primary pump manual - http://www.sta-rite.com/resources/images/913.pdf...
  • Page 17 The control of pit odor can be augmented by slowly and continually introducing biocatalytic enzymes into wastewater recycling and reclaim systems to biodegrade odor causing compounds. Although the process of introducing enzymes can reduce pit odor, water spots, chlorine use and break down grease and oils, it is not reclamation of wastewater nor should it be considered as a substitute for an efficient reclaim system.
  • Page 18 Reference list of users;  Training and customer service support.  Common and Avoidable Problems  Improper sizing of the reclaim system and related components;  Poor installation techniques such as faulty piping connections;  Improper PVC schedule;  Inadequate freeze protection;...
  • Page 19 10. Rotate the water motor by hand until it reaches the bottom of its travel range. Rotation should be smooth and relatively free of resistance. If not, diagnose the source of the resistance. ______________________ __________________________________ Reclaim Equipment Company Information Manual...
  • Page 20 14. Remove the reverse, pawl, and pawl retainer from the shaft by pulling on the hexagonal reverser restraint. 15. Inspect the pawl and reverser for wear. The reverser should rotate very smoothly with very little resistance. The corners and transitions should be well defined and not rounded. ______________________ __________________________________ Reclaim Equipment Company Information Manual...
  • Page 21 Removal of the water-motor allows for removal of the lower bulkhead. To remove the water- motor, remove the suction nozzles. One side of the speed reducer will slide allowing separation and removal of the speed reducer. ______________________ __________________________________ Reclaim Equipment Company Information Manual...
  • Page 22 5. When installing the pawl, hold it in place by applying pressure with your thumb, with the teeth aligned correctly. Rotate the shaft until the pawl is seated properly in the reverser threads. Once the pawl is installed, rotate the shaft several times to ensure that it is functioning properly. ______________________ __________________________________ Reclaim Equipment Company Information Manual...
  • Page 23: Figure 10: Self Cleaning Filter Components

    Dec 2011 V1.1 Figure 10: Self Cleaning Filter components ______________________ __________________________________ Reclaim Equipment Company Information Manual...
  • Page 24: Figure 11: Self Cleaning Filter Component Parts

    O-ring, upper bulkhead cap EPDM Cap, Upper bulkhead 6/6 Nylon 30% Glass filled Carriage rod assembly 316L SS rod and Tube Carriage rod washer 316L Carriage rod nut 316L Figure 11: Self Cleaning Filter component parts ______________________ __________________________________ Reclaim Equipment Company Information Manual...