Checklist For Troubleshooting And Error Correction - tams elektronik s88-Power Manual

Power supply for the s88 bus
Table of Contents

Advertisement

tams elektronik

4. Checklist for troubleshooting and error correction

!
Warning:
If you notice a strong heat development, immediately disconnect the connection to the
supply voltage. Fire hazard!
Possible causes:
The two connections "Interface" and "Power" are interchanged on the s88 bus. Thus the
current flows into the wrong direction. à Check the connections. Possibly the module s88-
Power and/or other current suppliers connected to the s88 bus line have been damaged.
The power pack provides a too high voltage. à Check the technical data of the power
supply unit. Possibly the module s88-Power and/or other current suppliers connected to the
s88 bus line have been damaged.
The s88-Power is defective. à Send in the s88-Power for inspection/repair.
No or faulty feedback
The two connections "Interface" and "Power" are interchanged on the s88 bus.
à Disconnect the power supply for the s88-Power immediately! Otherwise, the module
s88-Power and/or other current suppliers connected to the s88 bus line possibly are
damaged.
The connection to the power supply is interrupted, the LED lights up dimly or not at all.
à Check the connections.
The current of all connected s88-modules exceeds 700 mA. à Check the current of the
modules and connect additional moduldes s88-Power, if required.
There are s88 modules with RJ 45 connections connected to the bus line that do not comply
with the s88-N standard.