Network Connection Trouble-Shooting - Seitz Roundshot Livecam Generation 4 Installation Manual

Hide thumbs Also See for Roundshot Livecam Generation 4:
Table of Contents

Advertisement

3.3 Network connection trouble-shooting

If the connection cannot be established please follow these steps:
1.
Is the power cable with mains adaptor plugged-in and is the camera powered-
up? If so, the fans turn which creates a distinctive noise (even with closed
waterproof case).
2.
Do you know the IP of your camera? The standard (factory) IP is 192.168.1.80.
3.
Have you set the correct IP on your computer? The computer IP needs to be
different from the camera IP but in the same range, for example:
camera: 192.168.1.80
computer IP: 192.168.1.70
subnet mask: 255.255.255.0
gateway: 192.168.1.1
4.
If all fails, please reset the camera IP either to a fixed (factory) IP or to DHCP:
DHCP
fixed IP (192.168.1.80)
Reboot the computer by turning the power off/on.
Wait approximately 5 minutes for the camera to reinitialise.
It may be necessary to repeat this procedure.
Installation Manual Roundshot Livecam Generation 4 - April 2024 - © by Seitz Phototechnik AG / Switzerland