Paradyne MIM-2E1 Installation Instructions Manual

Micro interface module

Advertisement

Quick Links

MIM-2E1
Installation Instructions
Document Number MIM2-A2-GZ40-00
October 2004
Contents

Software and Firmware License Agreement

The terms and conditions of this License Agreement (the "Agreement") will apply
to the software and/or firmware (individually or collectively the "Software")
incorporated into the Paradyne product (the "Product") purchased by you and any
derivatives obtained from the Software, including any copy of either. If you have
executed a separate written agreement covering the Software supplied to you
under this purchase, such separate written agreement shall govern.
Paradyne Corporation ("Paradyne") grants to you, and you ("Licensee") agree to
accept a personal, non-transferable, non-exclusive, right (without the right to
MIM2-A2-GZ40-00
....................................................................................... 3
..................................................................................... 4
................................................................................................ 5
............................................................................................ 5
................................................................................................... 7
............................................................................................ 7
ONCE YOU HAVE READ THIS LICENSE AGREEMENT AND AGREE TO ITS
TERMS, YOU MAY USE THE SOFTWARE AND/OR FIRMWARE INCORPORATED
INTO THE PARADYNE PRODUCT. BY USING THE PARADYNE PRODUCT YOU
SHOW YOUR ACCEPTANCE OF THE TERMS OF THIS LICENSE AGREEMENT.
IN THE EVENT THAT YOU DO NOT AGREE WITH ANY OF THE TERMS OF THIS
LICENSE AGREEMENT, PROMPTLY RETURN THE UNUSED PRODUCT IN ITS
ORIGINAL PACKAGING AND YOUR SALES RECEIPT OR INVOICE TO THE
LOCATION WHERE YOU OBTAINED THE PARADYNE PRODUCT OR THE
LOCATION FROM WHICH IT WAS SHIPPED TO YOU, AS APPLICABLE, AND YOU
WILL RECEIVE A REFUND OR CREDIT FOR THE PARADYNE PRODUCT
PURCHASED BY YOU.
October 2004
...................................................... 1
.......................................................................... 3
......................................................... 3
.............................................................................. 6
........................................... 8
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MIM-2E1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Paradyne MIM-2E1

  • Page 1: Software And Firmware License Agreement

    Installation Instructions Document Number MIM2-A2-GZ40-00 October 2004 Contents Software and Firmware License Agreement Product Documentation Online Unpacking and Inspecting the Equipment Installing the MIM-2E1 Connecting the E1 Line E1 RJ45 Pinouts E1 Default Settings E1 Parameter Configuration LED Indicators Regulatory Notices...
  • Page 2: October

    sublicense) to use the Software, solely as it is intended and solely as incorporated in the Product purchased from Paradyne or its authorized distributor or reseller under the following terms and conditions: 1. Ownership: The Software is the sole property of Paradyne and/or its licensors. The Licensee acquires no title, right or interest in the Software other than the license granted under this Agreement.
  • Page 3: Product Documentation Online

    If you are not sure of the proper static control precautions, contact your nearest sales or service representative. If there is any visible damage, do not attempt to install the MIM-2E1; contact your sales representative. Installing the MIM-2E1 The MIM-2E1 Micro Interface Module provides additional uplink ports for the AµD8000 ADSL Micro DSLAM or BSX8000-5 Broadband Services Switch.
  • Page 4: Connecting The E1 Line

    2. Plug your E1 cables into the E1 RJ45 ports (Port 1 and Port 2) on the MIM-2E1 faceplate; the order of connection is not important. 3. Verify both connections: the Port 1 and Port 2 Lnk LEDs on the MIM-2E1 faceplate will flash green to indicate the connections are established and operational.
  • Page 5: E1 Rj45 Pinouts

    Position the choke as close as possible to the RJ45 connector. — Snap shut the ferrite choke. 2. Plug your E1 cable into one of the two E1 RJ45 ports on the MIM-2E1. Either port may be used. 3. Verify the connection: the E1 link LED on the front of the MIM will flash green to indicate the connection is established and operational.
  • Page 6: E1 Parameter Configuration

    Paradyne products meet the European minimum ones density requirement internally such that loss of synchronization is prevented between the MIM-2E1 and remote E1 equipment with AMI just as it is with HDB3. October 2004 MIM2-A2-GZ40-00...
  • Page 7: Led Indicators

    E1 line. Loss of Synchronization If the outgoing connection from the (LOS)The incoming connection MIM-2E1 has also been lost then the to the MIM-2E1 has been lost; remote E1 equipment to which the MIM no data is being received.
  • Page 8: Warranty, Sales, Service, And Training Information

    Cet appareil numérique de la classe A respecte toutes les exigences du règlement sur le matérial brouilleur du Canada. EUROPEAN REGULATORY COMPLIANCE The following regulatory compliance information applies to the MIM-2E1 as installed in the AµD8000 or BSX8000-5: This Class A product complies with European Norm EN55022.

Table of Contents