701999 46 V Dual Output Power Supply
Installation Guide for PN 701999
1. Tools required: Wire strippers,
drill, and screwdriver.
5. Connect Primary:
CAUTION: Have a licensed
electrician connect primary.
ATTENTION: Avoir un permis
électricien connecter primaire.
2. Supplies required: Electrical
enclosure for power supply, M4 pan
head screws, PLTC cable, silicone,
3M
Scotchlok
connectors.
™
™
NOTE: Ensure adequate ventilation. Power supply operating ambient temperature is -40º to
60º C. Power supply spacing to thermoplastic, wood, fiber, or other combustible type enclosure
materials shall be 1" (25 mm). Two (2) or more adjacent power supplies shall not be mounted
closer than 1" (25 mm) end-to-end or 4" (102 mm) side-to-side. Ensure power supplies are not
overloaded by verifying output current is less than 2.6 DC Amps (each output).
46 VDC output cables
Primary cable
Mounting tabs
3. Power Supply: Identify primary
wires, secondary wires, and
location of mounting tabs.
PAGE 1 OF 2
4. Mount Power Supplies:
Use mounting tab in corner to
secure power supply.
Need help?