Download Print this page

SloanLED 60W3 Installation Manual

12 vdc power supply

Advertisement

Quick Links

60W3 12 VDC Power Supply
Installation Guide for PN 701507-60W3 – NEC Class 2 Output
1. Tools required: Wire strippers,
drill, and screwdriver.
2. Supplies required: Junction box,
#8 or #10 pan head screws,
UL Listed PLTC cable, UL Listed
electrical wire connectors
(e.g., wirenuts), silicone.
12 VDC Output
(Red & Black)
Primary Wires
Mounting Tabs
3. Power Supply: Identify primary
wires, secondary wires, and
location of mounting tabs.
NOTE: Power supply operating temperature is -40º C to 60º C. To ensure adequate
ventilation, mounting power supplies without a secondary enclosure is recommended.
Space power supplies by standard knockout locations 3/4 in (19 mm) minimum. If two or
more power supplies are used, spacing must be at least 1 in (25 mm) end-to-end, and
4 in (102 mm) on each side. Power supply spacing to thermoplastic, wood, fiber, or
other combustible enclosure materials must be 1 in (25 mm). Ensure power supplies are
not overloaded by verifying output current is less than 5 DC Amps. Use of photo-cells or
timing device is recommended to ensure power supplies are off during day light hours,
when sign illumination is not needed. Higher daytime temperatures and unnecessary
operation may shorten power supply lifetime.
5. Configure Power Supplies: Secure power supplies to junction box using
1/2 in (13 mm) locknuts. Power supplies may be joined together in a wide array
of configurations. For wet locations use a junction box that is UL Listed for wet
locations. For dry locations, use any UL Listed junction box.
PAGE 1 OF 2
4. Mount Power Supplies:
Use mounting tab in corner to
secure power supply.

Advertisement

loading
Need help?

Need help?

Do you have a question about the 60W3 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SloanLED 60W3

  • Page 1 60W3 12 VDC Power Supply PAGE 1 OF 2 Installation Guide for PN 701507-60W3 – NEC Class 2 Output 12 VDC Output (Red & Black) Primary Wires Mounting Tabs 1. Tools required: Wire strippers, 2. Supplies required: Junction box, 3. Power Supply: Identify primary 4.
  • Page 2 60W3 12 VDC Power Supply PAGE 2 OF 2 Installation Guide for PN 701507-60W3 – NEC Class 2 Output Connect secondary TROUBLESHOOTING Wall penetration output. Ensure (seal with silicone) If sign is not functioning properly, check the following: all secondary...