Paradyne 7984 Installation Instructions Manual page 9

M/hdsl standalone termination unit with dsx-1 interface
Hide thumbs Also See for 7984:
Table of Contents

Advertisement

Table 3. System Options
Table 4. Communication Port (1 of 2)
7984-A2-GZ40-00
DSL Mode
Possible Settings: LTU, NTU
Default Setting: NTU
Controls whether the unit is configured as a control unit or tributary unit.
NOTE:
Changing this option will reset the card.
Test Timeout
Possible Settings: Enable, Disable
Default Setting: Enable
Allows tests to end automatically. The feature should be enabled when the unit is
remotely managed, so that control can be regained after a test is accidentally executed.
Test Duration (min)
Possible Settings: 1–120
Default Setting: 10
Number of minutes for a test to be active before automatically ending.
Telco Initiated Loopback
Possible Settings: Enable, Disable
Default Setting: Enable
Determines if the unit will respond to Telco loopback commands on the DSX-1 interface.
Remote Telco Loopback
Possible Settings: Enable, Disable
Default Setting: Disable
Determines if the unit will perform a Telco initiated loopback on just the local unit or if the
loopback will be performed on the remote DSL unit.
Port Use
Possible Settings: Terminal, Net Link
Default Setting: Terminal
Specifies how the communications port is to be used.
Port Type
Possible Settings: Asynchronous, Synchronous
Default Setting: Asynchronous
When Port Use is set to Net Link, Port Type controls whether the communication port
will be asynchronous or synchronous.
Data Rate
Possible Settings: 9.6, 14.4, 19.2, 28.8, 38.4
Default Setting: 9.6
Specifies the communication port baud rate.
February 1999