Download Print this page

rako WK-CONNECT Instruction Manual

In-ceiling wired connection unit

Advertisement

Quick Links

Instruction Manual
WK-CONNECT
In-ceiling wired connection unit
2024
Version 2.1.2

Advertisement

loading

Summary of Contents for rako WK-CONNECT

  • Page 1 Instruction Manual WK-CONNECT In-ceiling wired connection unit 2024 Version 2.1.2...
  • Page 2 5. Appendix 1 - Wiring Examples What is the WK-CONNECT? The WK-CONNECT is used to connect certain products to the Rako Wired network via a punchdown and RJ11. It also provides termination jumpers, which must be set appropriately for the system to work correctly.
  • Page 3 The termination requirements depend on the nature of the installation and the position of the WK-CONNECT within the system. No TERM - Both Jumpers removed When the WK-CONNECT is not at the end of line. This is usually identifiable by two cables being punched down to the WK-CONNECT.
  • Page 4 finding needs to be done on the wired network. For more information on fault finding on a wired network, see the links below. RAK-LINK diagnostics - For fault finding “Daisy Chain” and “STAR” configuration. RAK-STAR diagnostics - For fault finding “STAR” configuration. WK-CONNECT Version 2.1.2...
  • Page 5: Appendix 1 - Wiring Examples

    Cables run back to one or more central points, there can be one wired device on a single cable run or multiple, and the end of each line must have a STAR termination, if there are intermediate devices they must be set to UNTERM. WK-CONNECT Version 2.1.2...