Advertisement

Quick Links

User Manual
RS PRO 3102
stock number: 254-3502
M
rspro.com
VIBRATION METER
MAX
R
SET
REC
MIN
A
4
6
2
8
0
10
Datalogger
UNIT

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 3102 and is the answer not in the manual?

Questions and answers

Summary of Contents for RS PRO 3102

  • Page 1 User Manual RS PRO 3102 stock number: 254-3502 VIBRATION METER Datalogger UNIT rspro.com...
  • Page 2: Table Of Contents

    CONTENTS Title Page 1. SAFETY INFORMATION .............1 2. INTRODUCTION FEATURES............2 3. SPECIFICATIONS ...............3 4. PARTS & CONTROLS..............8 4-1 Description of Parts & Control Keys ........8 4-2 Description of Display............14 5. PREPARATIONS ...............17 5-1 Power Supply ...............17 5-2 Cable and Accelerometer Connection ........19 5-3 Accelerometer Mounting............20 6.
  • Page 3: Safety Information

    1. SAFETY INFORMATION To prevent bodily injury or damage to the meter, the following cautions must be observed. CAUTION Do not place the meter on an unstable place (shaky table or sloping place). If the meter falls down, it is very dangerous. Do not use and storage the place which moisture or dust, and where air with high salt or sulphur content, or other gase or chemicals.
  • Page 4: Introduction Features

    2. INTRODUCTION FEATURES The meter is designed mainly for routine maintenance and monitoring of rotational and other industrial machinery. Acceleration, velocity, and displacement can be easily measured using a suitable frequency range, allowing comprehensive and precise evaluation of machine vibrations. Applications: Industrial hygiene investigations Industrial machinery check-ups...
  • Page 5: Specifications

    3. SPECIFICATIONS Accelerometer Model PA-01 specification 1. Sensor: Voltage output type (built-in preamplifier) 2. Type: CCLD (Constant Current Line Drive) 3. Sensitivity: Listed on supplied calibration chart of PA-01 4. Transverse sensitivity: 5% or less 5. Frequency characteristics: 5Hz to 10kHz (±10%), 10kHz to 15kHz (±3dB) 6.
  • Page 6 11. Storage temperature and humidity: -30 to +80 ℃ , max. 90%RH 12. Size and weight: 22(D) x 52(H) mm / 72g Meter specification Measurement range (with PA-01 or PA-02) Acceleration (ACC): 0.02 ~ 200m/s² EQ PEAK 1Hz ~ 5kHz Velocity (VEL): 0.3 ~ 1000mm/s RMS 3Hz ~ 1kHz 0.1 ~ 1000mm/s RMS 10Hz ~ 1kHz Displacement (DISP): 0.02 ~ 100mm EQ PEAK 3Hz ~ 500Hz...
  • Page 7 Measurement range settings For piezoelectric accelerometer PA-01 and accelerometers with sensitivity is 1.0 ~ 9.9mV/(m/s²) Acceleration (ACC): 1, 10, 100, 1000 m/s² Velocity (VEL): 10, 100, 1000 mm/s Displacement (DISP): 0.1, 1, 10, 100 mm For accelerometers with sensitivity is 0.1 ~ 0.99 mV/(m/s²) Acceleration (ACC): 10, 100, 1000, 10000 m/s²...
  • Page 8 Display accuracy (electrical characteristics) Acceleration (ACC): Range full-scale ±2% (159.2Hz) Velocity (VEL): Range full-scale ±3% (159.2Hz) Displacement (DISP): Range full-scale ±5% (159.2Hz) Overall accuracy (in combination with PA-01 or PA-02) Acceleration (ACC): Range full-scale ±5% (159.2Hz) Velocity (VEL): Range full-scale ±7% (159.2Hz) Displacement (DISP): Range full-scale ±12% (159.2Hz) Headphone output: Vibration sound monitor Operating temperature and humidity: -10 ℃...
  • Page 9 Supplied accessories: Piezoelectric accelerometer PA-01x1, PA-02x1 Accessories for accelerometer Curled cable VA-02 x 1 Magnet attachment VA-01 x 1 IEC R6 batteries zinc-carbon x 4 Instruction manual x 1 PA-01 calibration chart x 1 PA-02 calibration chart x 1 CD software x 1 Micro-USB cable x 1 Optional accessories: AC adapter VA-03 M5x0.8 screw VA-04...
  • Page 10: Parts & Controls

    4. PARTS & CONTROLS 4-1 Description of Parts & Control Keys REC MAX UNIT 1. BNC input connector: The piezoelectric accelerometer is to be connected here, using the supplied curled cable. The power supply to drive the accelerometer (24V, 2mA) is always output from the BNC input connector.
  • Page 11 3. ACC/VEL DISP key: Press this key to select measurement of acceleration (ACC m/s²), velocity (VEL mm/s) or displacement (DISP mm) mode. 4. READ key: Press this key to enter or exit the manual data memory READ mode. 5. MEM key: Press this key one time to store the one data to memory.
  • Page 12 10. MODE key: Press this key to enter or exit the maximum/minimum recording mode. 11. UNIT/↵ key: UNIT: In the measurement mode, press “UNIT” key to change the measurement units. ↵ : In the setting mode, press ↵ key to enter or exit a setting mode or store the displayed setting.
  • Page 13 VEL: 10Hz to 1kHz, 3Hz to 1kHz DISP: 10Hz to 500Hz, 3Hz to 500Hz 15. PEAK RMS/P-P key: Press this key to select the display mode for each measurement mode. Once the setting is made, it will be used every time the measurement mode is selected. The following settings are available.
  • Page 14 ACC: 1, 10, 100, 1000 m/s² VEL: 10, 100, 1000 mm/s DISP: 0.1, 1, 10, 100 mm When using an accelerometer with a sensitivity of 0.1 to 0.99 mV/(m/s²). ACC: 10, 100, 1000, 10000 m/s² VEL: 100, 1000, 10000 mm/s DISP: 1, 10, 100, 1000 mm When using an accelerometer with a sensitivity of 10 to 99 mV/(m/s²).
  • Page 15 Important Use only the specified AC adapter. Using a different adapter may cause malfunction or damage. 19. Battery compartment: Four batteries (IEC R6, size AA) are inserted here. 20. USB socket: micro USB interface Piezoelectric accelerometer Curled cable (VA-02) BNC connector Piezoelectric accelerometer PA-01 PA-02...
  • Page 16: Description Of Display

    4-2 Description of Display REC MAX 1. Date/time: Shows the current, memory or recorded year, month/day, hour/minute, or second. : Year÷Month : Day-Hour : Minute : Second When power on the meter, will display the selected accelerometer model “ ”, “ ”...
  • Page 17 : Key lock indicator 5. OVER : OVER indicator If an overload condition has occurred during measurement, the indication OVER is flashing shown on the display. : Battery status indicator Four segment indicator shows the remaining batteries capacity. When the indication starts to flash, correct measurement is no longer possible.
  • Page 18 10. Bar graph display: Displays the present momentary value with a bar. The bar displays the value of the displayed data in intervals of approx 0.01 seconds. The scale value which agrees with the selected range is displayed. 11. Display mode: RMS: True effective value EQ PEAK: Equivalent peak value (RMSx EQ P-P: Equivalent peak-to-peak value (EQ PEAK x 2)
  • Page 19: Preparations

    5. PREPARATIONS The required matter is indicated before beginning measurement. Always set the power to OFF before inserting batteries and making any connections. 5-1 Power Supply The meter can be powered by four IEC R6 (size AA) batteries or by the optional AC adapter VA-03 (for 100 to 240V AC). Battery installation: When the meter is in operation, press key to turn off the...
  • Page 20 Selecting the battery type: Set the battery type used for the meter. The remaining battery capacity corresponding to the selected battery type is displayed. Available settings are Zinc-carbon, Alkaline and Ni-MH (nickel-metal hydride) battery. 1. Press key to turn on the meter. 2.
  • Page 21: Cable And Accelerometer Connection

    5-2 Cable and Accelerometer Connection Important Make sure that the power of the meter is turn to off before connecting or disconnecting the cable and accelerometer. Make the connection with the supplied curled cable VA-02, as shown in the illustration as follows. (VA-02) Curled cable BNC connector...
  • Page 22: Accelerometer Mounting

    5-3 Accelerometer Mounting There four basic methods attaching accelerometer measurement object. accelerometer mounting method greatly affects the contact resonance frequency. Please perform suitable method in consideration of the advantages and disadvantages of the four methods are outlined below. Contact resonance frequency: When the contact area between the accelerometer and the measurement object is partially deformed, a kind of spring system is created which vibrates at a frequency that is...
  • Page 23 Screw mounting (VA-04): Piezoelectric accelerometer Screw hole M5, P=0.8 M5 screw Effective depth 4 (VA-04) option 0.4a~1.6a Measurement object rspro.com...
  • Page 24 This mounting method is the best vibration characteristics. The mounting surface must have a surface smoothness of 0.4a ~ 1.6a. Use a fastening torque of 1 ~ 1.5 N-m for the accelerometer and the M5 screw that joins the accelerometer to measurement object.
  • Page 25 Flat magnet mounting (VA-01): Although a magnet can be used when the measurement subject is made of the metal which sticks to a magnet, due to this mounting method the contact resonance frequency will be quite low, this method is mainly suited for vibration measurements in the medium to low frequency range.
  • Page 26 Piezoelectric accelerometer Magnet attachment (VA-01) Measurement object (ferromagnetic) Rod attachment mounting (VA-06): Pressing the accelerometer against the measurement object with a rod is the simplest method, but it is only suitable for Piezoelectric accelerometer measurement below 500Hz, due to the contact resonance frequency will be very M5 screw low.
  • Page 27: Setup

    6. SETUP 6-1 Selecting the Accelerometer model 1. Press key to turn on the meter. 2. Press ▲ or ▼ key to enter the select accelerometer model mode for measurements, the previous selected accelerometer model is displayed. 3. Press ▲ or ▼ key to select the “ ”, “...
  • Page 28: Enable The Auto Power Off Function

    7. Press ↵ key to store the setting and exit this mode. 8. Press “MODE” key again to exit setting mode. 6-3 Enable the Auto Power off function 1. Press key to turn on the meter. 2. Press “MODE” key for 3 seconds to enter the setting mode, the “...
  • Page 29: Setting The Accelerometer Sensitivity

    6-4 Setting the Accelerometer Sensitivity Change the setting at the meter so that it matches the sensitivity indicated on the calibration chart of the used piezoelectric accelerometer. Round the sensitivity up as necessary. If you do not know about the accelerometer sensitivity, please refer to the section “7-4 calibration”.
  • Page 30 PA- 01 PA- 02 Model Model 1612278 1612279 Serial No. Serial No. 4.82 Voltage Sensitivity mV/(m/s Voltage Sensitivity mV/(m/s (159.2 Hz) (159.2 Hz) Inspected by Inspected by Temperature ℃ Temperature ℃ 2016.12 2016.12 Date Date RS PRO RS PRO rspro.com...
  • Page 31: Vibration Measurement

    7. VIBRATION MEASUREMENT 7-1 Vibration Measurement 1. Press key to turn on the meter. 2. Press “ACC/VEL/DISP” key to select the measurement mode. Press “FREQ RANGE” key to select the frequency range which suits the measurement purpose. Press “LEVEL RANGE” key to select the measurement range.
  • Page 32: Manual Data Memory And Read

    3. Press “PEAK/RMS/P-P” key to select the display mode as follows. ACC: EQ PEAK or RMS VEL: RMS or EQ PEAK DISP: EQ PEAK, RMS, or EQ P-P 4. When the input signal overloads the circuitry of the meter, the indication “ OVER ” appears. Using the “LEVEL RANGE”...
  • Page 33: Maximum & Minimum Recording Measurement

    3. To clear the manual memorized data Press key to turn on the meter. Press “MODE” key for 3 seconds to enter the setting mode, the “ ” mark is displayed. Press ▼ key 6 times to select this mode, the “ ”...
  • Page 34: Calibration

    7-4 Calibration Using Handheld Shake Calibrator (159.2Hz, 10m/s² rms or 1g rms) to verify the Accelerometer sensitivity. 1. Press key to turn on the meter. 2. Fix the accelerometer to the calibrator, then turn on the calibrator. 3. Press “MODE” key for 3 seconds to enter the setting mode, the “...
  • Page 35: Auto Datalogging

    7-5 Auto Datalogging Only micro SD CARD (Maximum capacity 32GB can be used) or Maximum 99 blocks. 1. Clear the auto memorized data Press key to turn on the meter. Press “MODE” key for 3 seconds to enter the setting mode, the “...
  • Page 36: Auto-Cycle Timer Datalogging

    5 Press ▲ or ▼ key to select desired interval time “ ” is 1s, 2s, 5s, 10s, 20s, 30s, 1m, 2m, 5m, 10m, 20m, 30m or 60m. 6 Press ↵ key to store the selecting and exit. 7 Press “MODE” key again to exit setting mode. 3.
  • Page 37: Cycle Timer Datalogging

    6. Using key, position the cursor on the time element to adjust. 7. Using ▲ and ▼ keys to setting the selected time element value. 8. Press ↵ key to enter the Record-Time setting mode, the “ ” mark and the flicking number of hour are displayed. 9.
  • Page 38 4. Press ▼ key 4 times to select this mode, the “ ” mark is displayed. 5. Press ↵ key to enter the Start-Time setting mode, the “ ” mark and the flicking number of year are displayed. 6. Using key, position the cursor on the date or time element to adjust.
  • Page 39: Rtc Button Cell Battery Replacement

    8. RTC BUTTON CELL BATTERY REPLACEMENT Open meter bottom cover, find the button cell battery. You can change button cell battery. CR1220 Button cell battery 9. MAINTENANCE Cleaning: Periodically wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents. Clean and dry as required.
  • Page 40 Limited Warranty This meter is warranted to the original purchaser against defects in material and workmanship for 3 years from the date of purchase. During this warranty period, RS Components will, at its option, replace or repair the defective unit, subject to verification of the defect or malfunction. This warranty does not cover fuses, disposable batteries, or damage from abuse, neglect, accident, unauthorized repair, alteration, contamination, or abnormal conditions of operation or handling.
  • Page 41 Africa Japan RS Components SA RS Components Ltd. P.O. Box 12182, West Tower (12th Floor), Vorna Valley, 1686 Yokohama Business Park, 20 Indianapolis Street, 134 Godocho, Hodogaya, Kyalami Business Park, Yokohama, Kanagawa 240-0005 Kyalami, Midrand Japan South Africa www.rs-components.com www.rs-components.com Asia U.S.A RS Components Pte Ltd.

This manual is also suitable for:

254-3502

Table of Contents