IIT-2000/2010/5000/5010 Instruction Manual/English Table of Contents SAFETY INSTRUCTIONS ............... 3 GETTING STARTED ............... 8 IIT-2000/2010/5000/5010 Overview ......10 Appearance ............15 Set Up ..............24 OPERATION ................32 Menu Tree ............. 34 Test Lead Connection ..........39 ACW, DCW, IR and GB Manual Testing ....42 Special MANU Test Mode (000) ......
Page 4
IIT-2000/2010/5000/5010 Instruction Manual/English Fuse Replacement ..........197 Test Errors ............198 IIT-2000/2010/5000/5010 Specifications ....201 IIT-2000 Dimensions ..........210 IIT-2010 Dimensions ..........211 IIT-5010 Dimensions ..........212 IIT-5000 Dimensions ..........213 Declaration of Conformity ........215 INDEX ..................216 05/08/2015 Version No. 001...
IIT-2000/2010/5000/5010 Instruction Manual/English AFETY INSTRUCTIONS This chapter contains important safety instructions that you must follow during operation and storage. Read the following before any operation to ensure your safety and to keep the instrument in the best possible condition. Safety Symbols These safety symbols may appear in this manual or on the instrument.
Page 6
Do not disassemble the IIT-2000/2010/5000/5010 unless you are qualified. (Measurement categories) EN 61010-1:2010 specifies the measurement categories and their requirements as follows. The IIT-2000/2010/5000/5010 does not fall under category II, III or IV. Measurement category IV is for measurement performed at the source of low- voltage installation.
Page 7
(Pollution Degree) EN 61010-1:2010 specifies the pollution degrees and their requirements as follows. The IIT-2000/2010/5000/5010 falls under degree 2. Pollution refers to “addition of foreign matter, solid, liquid, or gaseous (ionized gases), that may produce a reduction of dielectric strength or surface resistivity”.
Page 8
IIT-2000/2010/5000/5010 Instruction Manual/English The pollution has no influence. Pollution degree 2: Normally only non-conductive pollution occurs. Occasionally, however, a temporary conductivity caused by condensation must be expected. Pollution degree 3: Conductive pollution occurs, or dry, non-conductive pollution occurs which becomes conductive due to condensation which is expected.
Page 9
IIT-2000/2010/5000/5010 Instruction Manual/English Power cord for the United Kingdom When using the safety tester in the United Kingdom, make sure the power cord meets the following safety instructions. NOTE: This lead/appliance must only be wired by competent persons WARNING: THIS APPLIANCE MUST BE EARTHED...
Set Up chapter. IIT-2000/2010/5000/5010 Overview ..........10 Series lineup ......................10 Model Overview ...................... 11 Main Features ......................11 Accessories ......................12 Package Contents ....................14 Appearance ................15 IIT-2000/5000 Front Panel ..................15 05/08/2015 Version No. 001...
Page 11
IIT-2000/2010/5000/5010 Instruction Manual/English IIT-2010/5010 Front Panel ..................15 IIT-2000/2010 Rear Panels ..................20 IIT-5000 Rear Panel ....................20 IIT-5010 Rear Panel ....................21 Set Up ..................24 Line Voltage Connection and Power Up ..............24 Installing the Optional GPIB Card ................26 Workplace Precautions ...................
The IIT-2000/2010/5000/5010 can store up to 100 manual tests, as well as run up to 16 manual tests sequentially as an automatic test, allowing the safety testers to accommodate any number of safety standards, including IEC, EN, UL, CSA, GB, JIS and others.
IIT-2000/2010/5000/5010 Instruction Manual/English Features Ramp up time control Safety discharge 100 test conditions (MANU mode) 100 automatic tests (AUTO mode) Over temperature, voltage and current protection Pass, Fail, Test, High Voltage and Ready indicators ...
Page 15
IIT-2000/2010/5000/5010 Instruction Manual/English GTL-115 x1 GB Test leads (IIT-2010/5010 only) Remote terminal male plug Interlock key Optional Accessories Part number Description GHT-205 High Voltage Test Probe GHT-113 High Voltage Test Pistol GTL-232 RS232C cable GTL-248 GPIB cable GTL-247 USB cable...
IIT-2000/2010/5000/5010 Instruction Manual/English Package Contents Check the contents before using the IIT-2000/2010/5000/5010. Opening the box Contents IIT-2000/2010/5000/5010 GHT-114 test leads x1 (single unit) Quick Start guide GTL-115 test leads x1 (IIT-2010/5010) User manual CD ...
IIT-2000/2010/5000/5010 Instruction Manual/English Appearance IIT-2000/5000 Front Panel PASS/FAIL indicators Display Function keys Directional keys READY indicator TEST indicator PASS FAIL READY TEST AC / DC Withstanding Voltage / G P T -9 8 0 3 Tester Insulation Resistance CAUTION 5.0 kVAC MAX.
Page 18
IIT-2000/2010/5000/5010 Instruction Manual/English Display 240 X 64 dot matrix display (LCD) Function keys The function keys correspond to the soft-keys directly above on the main display. PASS FAIL Pass/Fail The PASS and FAIL indicators light up upon a PASS or FAIL test result at the end of a manual indicators test or automatic test.
Page 19
IIT-2000/2010/5000/5010 Instruction Manual/English CAUTION 5.0 kVAC MAX. HIGH VOLTAGE The HIGH VOLTAGE indicator will light up when HIGH VOLTAGE 6.0 kVDC MAX. indicator an output terminal is active. Only after the test has finished or stopped will the indicator turn off.
Page 20
IIT-2000/2010/5000/5010 Instruction Manual/English Scroll wheel The scroll wheel is used to edit parameter values. UTILITY UTILITY key Used to enter the MANU Utility or Common Utility menu. EDIT/SAVE EDIT/SAVE key Used to start editing MANU/AUTO tests as well as save settings and parameters.
Page 21
IIT-2000/2010/5000/5010 Instruction Manual/English START START button The START button is used to start tests. The START button can be used to start tests when the tester is in the READY status. Pressing the START button will put the tester in the TEST status.
IIT-2000/2010/5000/5010 Instruction Manual/English IIT-2000/2010 Rear Panels SIGNAL I/O USB A port RS232 port WARNING TO AVOID ELECTRIC SHOCK THE POWER CORD SIGNAL I / O RS 232 PROTECTIVE GROUNDING CONDUCTOR MUST BE CONNECTED TO GROUND . FOR CONTINUED FIRE PROTECTION...
IIT-2000/2010/5000/5010 Instruction Manual/English IIT-5010 Rear Panel Signal I/O, RS232 High voltage terminal & USB port Fan vents CAUTION HIGH VOLTAGE WARNING TO AVOID ELECTRIC SHOCK THE POWER CORD PROTECTIVE GROUNDING CONDUCTOR MUST BE SIGNAL I / O RS232 CONNECTED TO GROUND.
Page 24
IIT-2000/2010/5000/5010 Instruction Manual/English Fan/Fan Vents Exhaust fan. Allow enough room for the fan to vent. Do not block the fan openings. Connect the GND (ground) terminal to the earth ground. Line voltage Line voltage input: 100/120/220/230VAC ±10% input Line voltage...
Page 25
IIT-2000/2010/5000/5010 Instruction Manual/English HIGH VOLTAGE IIT-5000/5010 The HIGH VOLTAGE terminal output is used CAUTION output terminal for outputting the testing voltage. HIGH VOLTAGE MAX. 5.0 kVAC 6.0 kVDC WARNING USE EXTREME CAUTION. Do not touch the HIGH VOLTAGE terminal during testing.
IIT-2000/2010/5000/5010 Instruction Manual/English Set Up Line Voltage Connection and Power Up Background Before powering up the IIT-2000/2010/5000/5010 ensure the correct voltage has been selected on the rear panel. The IIT- 2000/2010/5000/5010 supports line voltages of 100V/120V/220V and 230V. 1. Check the line voltage and the fuse in the fuse...
Page 27
IIT-2000/2010/5000/5010 Instruction Manual/English Ensure the power cord is connected to an earth ground. Warning Failure could be harmful to the operator and instrument. POWER 4. Press the Power button. 5. When the unit is powering up, all the LED indicators will light.
IIT-2000/2010/5000/5010 Instruction Manual/English Installing the Optional GPIB Card The optional GPIB is a user-installable option. Follow the Background instructions below to install the GPIB card. Before installing the optional GPIB card ensure the IIT- WARNING 2000/2010/5000/5010 is turned off and disconnected from power.
IIT-2000/2010/5000/5010 Instruction Manual/English Workplace Precautions The IIT-2000/2010/5000/5010 is a high voltage instrument that Background outputs dangerous voltages. The following section describes precautions and procedures that must be followed to ensure a safe work environment. The IIT-2000/2010/5000/5010 generates voltages in excess of WARNING 5kVAC or 6kVDC.
Operating Precautions Background The IIT-2000/2010/5000/5010 is a high voltage instrument that outputs dangerous voltages. The following section describes precautions and procedures that must be followed to ensure that the tester is operated in a safe manner.
Page 31
IIT-2000/2010/5000/5010 Instruction Manual/English Do not turn the power off when a test is running, unless in an emergency. 3. Only use those test leads supplied with the instrument. Leads with inappropriate gauges can be dangerous to both the operator and the instrument.
Page 32
10. Ensure an adequate discharge time for the DUT. When DCW or IR tests are performed, the DUT, test leads and probes become highly charged. The IIT-2000/2010/5000/5010 has discharge circuitry to discharge the DUT after each test. The time required for a DUT to discharge depends on the DUT and test voltage.
IIT-2000/2010/5000/5010 Instruction Manual/English Basic Safety Checks The IIT-2000/2010/5000/5010 is a high voltage device and as Background such, daily safety checks should be made to ensure safe operation. 1. Ensure all test leads are not broken and are free from defects such as cracks or splitting.
Page 34
IIT-2000/2010/5000/5010 Instruction Manual/English PERATION Menu Tree .................. 34 Menu Tree Overview ....................35 Test Lead Connection ..............39 ACW, DCW, IR Connection ..................39 GB Connection ......................40 ACW, DCW, IR and GB Manual Testing ......... 42 Choose/Recall a Manual Test Number ..............44 Edit Manual Test Settings ..................
Page 35
IIT-2000/2010/5000/5010 Instruction Manual/English Setting the ARC Mode .................... 58 Setting PASS HOLD ....................62 Setting FAIL MODE ....................63 Setting MAX HOLD ....................65 Setting the Grounding Mode ................... 66 Saving and Exiting EDIT Status ................71 Running a MANU Test .................... 72 PASS / FAIL MANU Test ..................
Menu Tree This section describes the overall structure of the operation statuses and modes for the IIT-2000/2010/5000/ 5010 safety testers. The testers have two main testing modes (MANU, AUTO) and 5 main operation statuses (VIEW, EDIT, READY, TEST and STOP).
IIT-2000/2010/5000/5010 Instruction Manual/English Menu Tree Overview VIEW status VIEW status is used to view the parameters of the selected manual test/automatic test. The VIEW status is also used to put the tester into MANU or AUTO mode. VIEW status A U T O = 0 0 1 - 0 0 2...
Page 38
IIT-2000/2010/5000/5010 Instruction Manual/English READY status When the tester is in READY status, it is ready to begin testing. Pressing the START button will begin testing and put the tester into TEST status. Pressing the MANU/AUTO key will return the tester to VIEW status.
Page 39
IIT-2000/2010/5000/5010 Instruction Manual/English Page View Up to 16 tests can be used to create an automatic test. Page View is used to see which manual tests (steps) an automatic test is composed of. The steps can be re-arranged and deleted in Page View.
Page 40
IIT-2000/2010/5000/5010 Instruction Manual/English Common Utility This utility controls the LCD, buzzer, interface and control Settings settings. These settings are system wide. T I L I T Y S t a r t t r l F R O N T...
IIT-2000/2010/5000/5010 Instruction Manual/English Test Lead Connection This section describes how to connect the IIT-2000/2010/5000/5010 to a DUT for withstanding, insulation resistance or ground bond testing. ACW, DCW, IR Connection Background ACW, DCW and IR tests use the HIGH VOLTAGE terminal and RETURN terminal with the GHT-114 test leads.
IIT-2000/2010/5000/5010 Instruction Manual/English HIGH VOLTAGE Terminal RETURN Terminal GB Connection Background GB tests use the SENSE H/L and SOURCE H/L terminals with the GTL-115 test leads. IIT-2010/5010 GB Connection Source H Sense H Source L Sense L Steps 1. Turn the power off on the safety tester.
Page 43
IIT-2000/2010/5000/5010 Instruction Manual/English Sense H lead Sense L lead RETURN HI- POT GB Rx SENSE H SENSE L Source H lead Source L lead SOURCE H SOURCE L 05/08/2015 Version No. 001...
IIT-2000/2010/5000/5010 Instruction Manual/English ACW, DCW, IR and GB Manual Testing single This section describes how to create, edit and run a ACW, DCW, IR or GB only applies to the safety test. Each Manual setting described in this chapter manual test –...
Page 45
Zeroing of the Test Leads (GB only) → from page 83 Special MANU Test Mode (000) → from page 86 Before operating the IIT-2000/2010/5000/5010, please read the safety precautions as outlined in the Set Up chapter on page 24. 05/08/2015 Version No. 001...
IIT-2000/2010/5000/5010 Instruction Manual/English Choose/Recall a Manual Test Number Background ACW, DCW, IR and GB tests can only be created in the MANU (manual) mode. MANU number 001 to 100 can be saved and thus be loaded when editing/creating a MANU test or AUTO test.
IIT-2000/2010/5000/5010 Instruction Manual/English Pressing the EDIT/SAVE key again will save the settings for Note the current test and return back to VIEW status. Setting the Test Function Background After a MANU number has been chosen and the tester is in EDIT status, a test function can be set.
IIT-2000/2010/5000/5010 Instruction Manual/English Setting the Test Voltage or Test Current The test voltage can be set from 0.050kV to 5kV for ACW, Background 0.050kV to 6kV for DCW and 0.050 to 1kV for IR (50V steps*). For GB tests the test current can be set from 3A to 30A (IIT- 2010) or 3A to 32A (IIT-5010).
When setting the voltage, be aware that a maximum of 200VA Note can be set for ACW and 50W for DCW (IIT-2000/2010) or 500VA and 100W, respectively for IIT-5010/5000. The ground bond voltage (GBV) is calculated as the HI SET limit x Test Current.
IIT-2000/2010/5000/5010 Instruction Manual/English 2. Use the scroll wheel to set the test frequency. ACW, GB 50Hz, 60Hz The test frequency can only be set for ACW or GB tests. Note Setting the Upper and Lower Limits Background There is both a LO and HI judgment setting. When the measured value is below the LO SET setting, the test will be judged as FAIL.
Page 52
IIT-2000/2010/5000/5010 Instruction Manual/English 2. Use the scroll wheel to set the HI SET/LO SET limit*. ACW (HI) 0.001mA~042.0mA (IIT-2000/2010) 0.001mA~110.0mA (IIT-5000/5010) DCW (HI) 0.001mA~011.0mA (IIT-2000/2010) 0.001mA~021.0mA (IIT-5000/5010) 0001MΩ ~ 9999MΩ (IIT-2010) IR (LO) 0.001GΩ ~ 50.00GΩ (IIT-5010) 000.1mΩ ~ 650.0mΩ...
Page 53
SET limit cannot be greater than the HI SET limit. When setting the current, be aware that a maximum of 200VA can be set for ACW and 50W for DCW (IIT-2000/2010) or 500VA and 100W, respectively for IIT-5010/5000. 05/08/2015 Version No. 001...
IIT-2000/2010/5000/5010 Instruction Manual/English Setting a Reference Value The REF# acts as an offset. The REF# value is subtracted Background from the measured current (ACW, DCW) or measured resistance (IR, GB). 1. Press the UP / DOWN arrow keys to bring the cursor...
IIT-2000/2010/5000/5010 Instruction Manual/English Setting the Test Time (Timer) The TIMER setting is used to set the test time for the current Background test. The test time determines how long the test voltage or current is applied to the DUT. This test time does not include...
Page 56
With the ACW test function, when the test current is between Note 30mA and 40mA (IIT-2000/2010) or 80mA and 100mA (IIT- 5010/5000), the ramp time + test time cannot exceed 240 seconds. At this current level, the tester also needs to pause after a test for a time equal to or greater than the output time.
The timer cannot be turned off (limited to 240s) if the test current is between 30mA and 40mA (IIT-2000/2010) or 80mA and 100mA (IIT-5010/5000) in ACW mode. The discharge time and initial test time cannot be edited.
IIT-2000/2010/5000/5010 Instruction Manual/English Steps 1. Use the UP/DOWN arrow keys to bring the cursor to the RAMP setting. M A N U = * * * - 0 0 0 0 m A F R E Q = 0 H z 1 .
Page 59
IIT-2000/2010/5000/5010 Instruction Manual/English Steps 1. Use the UP/DOWN arrow keys to bring the cursor to the MANU test file name at the top of the screen. The test file name is initially set as MANU_NAME. cursor M A N U = * * * - 0 0...
IIT-2000/2010/5000/5010 Instruction Manual/English Setting the ARC Mode ARC detection, otherwise known as flashover detection, Background detects fast voltage or current transients that are not normally detected. Arcing is usually an indicator of poor withstanding insulation, electrode gaps or other insulating problems that cause temporary spikes in current or voltage during ACW and DCW testing.
Page 61
IIT-2000/2010/5000/5010 Instruction Manual/English The MANU UTILITY settings only apply to the selected MANU Note test. 2. Use the UP/DOWN arrow keys to move to the ARC MODE setting. 3. Use the scroll wheel to set the ARC mode. OFF, ON AND CONTINUE,...
Page 62
IIT-2000/2010/5000/5010 Instruction Manual/English 7. Use the scroll wheel to edit the ARC level. IIT-2000/2010: 1.000mA~080.0mA 1.000mA~020.0mA IIT-5010/5000: 2.000mA~200.0mA 2.000mA~040.0mA 05/08/2015 Version No. 001...
Page 63
IIT-2000/2010/5000/5010 Instruction Manual/English The ARC setting range is directly related to the HI SET current Note limit. ACW: IIT-2000/2010 HI SET Limit ARC Range 0.001mA~0.999mA 1.000mA ~2.000mA 01.00mA~09.99mA 01.00mA ~20.00mA 010.0mA~042.0mA 001.0mA ~080.0mA ACW: IIT-5010/5000 HI SET Limit ARC Range 0.001mA~1.100mA...
IIT-2000/2010/5000/5010 Instruction Manual/English Setting PASS HOLD The PASS HOLD settings only apply to the selected test in an Background AUTO test. When the PASS HOLD setting is set to ON, a PASS judgment is held until the START button is pressed.
IIT-2000/2010/5000/5010 Instruction Manual/English PASS OFF, ON HOLD EDIT/SAVE 4. Press the EDIT/SAVE key to save and exit the MANU Utility menu. The ESC key can be pressed at any time in the MANU Utility Note menu to cancel and exit.
Page 66
IIT-2000/2010/5000/5010 Instruction Manual/English The FAIL MODE setting only applies to AUTO tests. This Note setting is ignored when running MANU tests. UTILITY Steps 1. Press the UTILITY key on the front panel when the tester is in MANU/EDIT status. The display will go from the normal EDIT status to the MANU Utility menu for the current test.
IIT-2000/2010/5000/5010 Instruction Manual/English Setting MAX HOLD Background The MAX HOLD setting will hold the maximum current measured in the ACW and DCW tests or the maximum resistance measured in IR and GB tests. UTILITY Steps 1. Press the UTILITY key on the front panel when the tester is in EDIT status.
Setting the Grounding Mode Background When GROUND MODE is set to ON, the IIT-2000/ 2010/5000/5010 grounds the return terminal to the ground. This mode is best for DUTs that are grounded to an earth ground by their chassis, fixtures or operation environment.
Page 69
IIT-2000/2010/5000/5010 Instruction Manual/English measure to a higher resolution. The GROUND MODE is always set to OFF for IR and GB tests. GROUND MODE = ON, DUT grounded IIT-2000/ 2010/5000/5010 High Voltage stray terminal resistance, Return terminal capacitance GROUND MODE = ON, DUT floating...
Page 70
IIT-2000/2010/5000/5010 Instruction Manual/English GROUND MODE = OFF, DUT floating IIT-2000/2010/5000/5010 High Voltage stray terminal resistance, Return terminal capacitance IIT-2010/5010(GB testing) Source H stray Sense H resistance, Sense L capacitance Source L GROUND MODE = OFF, DUT grounded IIT-2000/2010/5000/5010 High Voltage...
Page 71
IIT-2000/2010/5000/5010 Instruction Manual/English When GROUND MODE is set to OFF, the DUT, fixtures or Warning connected instrumentation cannot be grounded. This will short circuit the internal circuitry during a test. For ACW and DCW tests, if it is not known whether the DUT...
Page 72
IIT-2000/2010/5000/5010 Instruction Manual/English 3. Use the scroll wheel to set the GROUND MODE. GROUND MODE OFF, ON EDIT/SAVE 4. Press the EDIT/SAVE key to save and exit the MANU Utility menu. 5. The GROUND MODE icon on the display changes accordingly.
IIT-2000/2010/5000/5010 Instruction Manual/English Saving and Exiting EDIT Status After all test parameters have been set, the test can be saved. Background After a test is saved it can be used when creating an AUTO test. The special MANU number, 000, can be saved, however it Warning cannot be used for AUTO tests.
IIT-2000/2010/5000/5010 Instruction Manual/English Running a MANU Test Background A test can be run when the tester is in READY status. The tester cannot start to run a test under the following Note conditions: A protection setting has been tripped; when a protection setting has been tripped the corresponding error message is displayed on the screen.
Page 75
IIT-2000/2010/5000/5010 Instruction Manual/English VIEW status M A N U = * * * - 0 0 0 0 m A F R E Q = 0 H z 1 . 0 0 m A 0 100 A M P 0 0 . 1 S = 0 0 1 .
Page 76
IIT-2000/2010/5000/5010 Instruction Manual/English TEST status M A N U = * * * - 0 0 0 0 m A F R E Q = 0 H z 1 . 0 0 m A 00 00 0 100 A M P 0 0 .
Page 77
IIT-2000/2010/5000/5010 Instruction Manual/English Measured Resistance IR Example Test Voltage M A N U = * * * - 0 0 0 0 M Ω 1 1 0 0 M Ω 0 050 1056 M Ω A M P 0 0 . 1 S = 0 0 3 .
Page 78
IIT-2000/2010/5000/5010 Instruction Manual/English MANU/AUTO Exit TEST Status To exit testing, press the MANU/AUTO key when the tester is in the READY status. The tester will revert to the VIEW status for the current test. M A N U = * * * - 0 0...
IIT-2000/2010/5000/5010 Instruction Manual/English PASS / FAIL MANU Test If the test is allowed to run to completion (the test is not Background stopped or a protection setting is not tripped) then the tester will judge the test as either PASS or FAIL.
Page 80
IIT-2000/2010/5000/5010 Instruction Manual/English STOP Pressing the STOP button will return the tester to the READY status. START Pressing the START button will restart the test. The buzzer will only sound if the Pass Sound is set to ON. Note See page 113 for details.
Page 81
IIT-2000/2010/5000/5010 Instruction Manual/English DCW PASS START Timing TEST PASS Output V time RAMP TEST TIME Initial time Discharge time (Approximately 150ms) IR PASS Timing START TEST PASS Output V time RAMP TEST TIME Initial time Discharge time (Approximately 150ms) GB PASS...
Page 82
IIT-2000/2010/5000/5010 Instruction Manual/English FAIL FAIL Judgment 1. When the test is judged as FAIL, FAIL will be displayed, the buzzer will sound and the FAIL indicator will be lit red. As soon as a test is judged FAIL, power is cut from the terminals.
Page 83
IIT-2000/2010/5000/5010 Instruction Manual/English FAIL Timing The timing diagrams below show the ACW, DCW, IR and GB Diagrams timing for the START status, TEST status and FAIL judgment. ACW FAIL START Timing TEST FAIL Output V time RAMP TEST TIME Initial time...
Page 84
IIT-2000/2010/5000/5010 Instruction Manual/English GB FAIL Timing START TEST FAIL Output I time 0.5s Total Test Time Initial time (Approximately 150ms) 05/08/2015 Version No. 001...
IIT-2000/2010/5000/5010 Instruction Manual/English Zeroing of the Test Leads (GB only) The Zeroing function is used to determine the resistance of Background the test leads for GB tests. When a zero check is performed, the reference is automatically set to the measured resistance of the test leads.
Page 86
IIT-2000/2010/5000/5010 Instruction Manual/English STOP 3. Press the STOP button to put the tester into the READY status. E R O 4. The ZERO function can be activated by pressing the corresponding soft-key in the READY status. The ZERO soft-key will be highlighted.
Page 87
IIT-2000/2010/5000/5010 Instruction Manual/English Reference value M A N U = * * * - 0 0 . 7 m Ω F R E Q = 0 H z 0 0 . 0 m Ω 0 3 01 m Ω G B V = = 0 0 3 .
IIT-2000/2010/5000/5010 Instruction Manual/English Special MANU Test Mode (000) Special Test When MANU number 000 is selected, the special test mode is Mode Overview activated. Under the special test mode, the voltage can be changed during a test, in real time (ACW, DCW only). The test function can also be changed when in READY or VIEW status, unlike under normal operation.
Page 89
IIT-2000/2010/5000/5010 Instruction Manual/English Current Voltage Test V Meas. I time RAMP TIME TEST time Start time Legend: Voltage: Current The test items that are plotted on the sweep graph depend on the type of test that is performed. TEST Graph Test Items...
Page 90
IIT-2000/2010/5000/5010 Instruction Manual/English A C W 2. The settings of a previous test can be loaded by pressing the corresponding soft-key in the VIEW or Example: READY status. For example, if you are currently in DCW mode, pressing the ACW key will load the ACW settings that were previously used in the special manual mode.
Page 91
IIT-2000/2010/5000/5010 Instruction Manual/English T A . Setting the 1. When in the VIEW status, press the STA.t key and Sweep Start set the starting time for the sweep graph. Make Time sure that the sweep start time is significantly less than the test time.
Page 92
IIT-2000/2010/5000/5010 Instruction Manual/English View Sweep Unlike normal manual tests, the special test mode also has an Graph option to view the resultant test as a sweep graph. This option is only available for the IIT-5000/5010. W E E Steps 1. When the test has finished, press the SWEEP key to view the results of the sweep in a graph.
Page 93
IIT-2000/2010/5000/5010 Instruction Manual/English 2. Use the scroll wheel to move the cursor on the time axis (x-axis). The measured values for the primary and secondary items at that particular point in time Test Voltage are shown on the left-hand side.
Running an Automatic Test → from page 102 Automatic Test Results → from page 107 Before operating the IIT-2000/2010/5000/5010, please read the safety precautions as outlined in the Set Up chapter on page 24. 05/08/2015 Version No. 001...
IIT-2000/2010/5000/5010 Instruction Manual/English Choose/Recall an Automatic Test Background The tester must first be put into AUTO mode to create or run automatic tests. Up to 100 automatic tests can saved/recalled. MANU/AUTO 1. If the tester is in MANU mode, press and hold the Steps MANU/AUTO key for three seconds.
IIT-2000/2010/5000/5010 Instruction Manual/English 2. Use the scroll wheel to choose the AUTO number. AUTO # 001~100 AUTO number A U T O = 0 0 1 - 1 0 0 0 m A F R E Q = 0 H z 1 .
IIT-2000/2010/5000/5010 Instruction Manual/English 2. Use the scroll wheel to choose a MANU number to add to the automatic test. MANU number 001~100 A D D 3. Press the ADD soft-key to add the selected manual test to the automatic test as another step.
Page 99
IIT-2000/2010/5000/5010 Instruction Manual/English Character List 0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K W X Y Z a b c d e f g h i j k w x y z + - * / _ = : Ω...
IIT-2000/2010/5000/5010 Instruction Manual/English Saving and Exiting EDIT Status Background After all test steps have been added to an automatic test, the automatic test can be saved. EDIT/SAVE 1. When in EDIT status, press the EDIT/SAVE key to Steps save the automatic test. After the test is saved the tester will revert back to VIEW status.
IIT-2000/2010/5000/5010 Instruction Manual/English Automatic Test Page View Pressing the PAGE key will show an overview of the tests for Background the currently selected automatic test when in the VIEW status. The Page View will show the order of the AUTO test steps as well as the manual file name, function, test voltage/current and HI/LO SET limits.
Page 102
IIT-2000/2010/5000/5010 Instruction Manual/English Selected cursor AUTO test file name MANU test file name A U T O = 0 0 1 - 0 1 M A N U _ N A C W = 0 . 0 0 k 1 . 0 0 m A...
Page 103
IIT-2000/2010/5000/5010 Instruction Manual/English Swapping Two 1. Use the UP/DOWN and LEFT/RIGHT arrow Steps keys to move the cursor to the test step you wish to swap. W A P 2. Press the SWAP soft-key. 3. Use the UP/DOWN and LEFT/RIGHT arrow keys to move the cursor to the second step.
IIT-2000/2010/5000/5010 Instruction Manual/English The next time the automatic test is run, the steps with Note asterisks will be skipped. Delete a Test 1. Use the UP/DOWN and LEFT/RIGHT arrow keys to move the cursor to the test step you Step wish to delete.
Page 105
IIT-2000/2010/5000/5010 Instruction Manual/English following conditions: Any protection modes have been tripped. The INTERLOCK function is ON and the Interlock key is not inserted in the signal I/O port (page 127). The STOP signal has been received remotely.
Page 106
IIT-2000/2010/5000/5010 Instruction Manual/English READY status A U T O = 0 0 1 - 1 0 0 0 m A F R E Q = 0 H z 1 . 0 0 m A 0 100 A M P 0 0 . 1 S = 0 0 1 .
Page 107
IIT-2000/2010/5000/5010 Instruction Manual/English PASS/FAIL 1. If Pass Hold is set to ON or Fail Mode is set to HOLD for a manual test, then the tester will “hold” the testing after a HOLD Pass/Fail result for that particular test. See page 61, 63 for details.
Page 108
IIT-2000/2010/5000/5010 Instruction Manual/English STOP Stop a Running 1. To stop the AUTO test at any time when it is Test running, press the STOP button. The AUTO test will stop immediately. When the STOP button is pressed, a judgment is not made on the current test and any remaining tests are aborted.
IIT-2000/2010/5000/5010 Instruction Manual/English MANU/AUTO Exit Testing To exit testing, press the MANU/AUTO key when the tester is in the READY status. The tester will revert to the VIEW status for the current automatic test. A U T O = 0 0 1 - 1 0...
Page 110
IIT-2000/2010/5000/5010 Instruction Manual/English compose the automatic test: Each step must be passed for a PASS judgment (excluding skipped tests). A FAIL result for a single step will result in FAIL for the whole automatic test. A STOP. No step can be stopped for a PASS/FAIL judgment to be made.
Page 111
IIT-2000/2010/5000/5010 Instruction Manual/English A U T O = 0 0 1 - * * # 0 1 : P A S # 0 2 : P A S # 0 3 : P A S # 0 4 : P A S...
Page 112
IIT-2000/2010/5000/5010 Instruction Manual/English 2. Turn the scroll wheel left to return back to the overview table. Return to Ready 1. The PASS/FAIL results will be held on the screen Status until the STOP button is pressed. STOP 2. To put the tester back into READY status, press the STOP button (twice for a fail result).
Page 113
IIT-2000/2010/5000/5010 Instruction Manual/English PASS Timing START Diagram TEST PASS Output V time step 1 ~ step 16 FAIL Timing START Diagram TEST FAIL Output V time step 1 ~ step 16 05/08/2015 Version No. 001...
IIT-2000/2010/5000/5010 Instruction Manual/English Common Utility Settings The Common Utility settings are system-wide settings that apply to both MANU tests and AUTO tests. The Common Utility menu includes the following settings: LCD settings → from page 112. Buzzer Settings → from page 113.
Page 115
IIT-2000/2010/5000/5010 Instruction Manual/English L C D 3. Press the LCD soft-key to bring up the LCD Common Utility menu. T I L I T Y L C D t r a s t : L C D g h t...
Page 116
IIT-2000/2010/5000/5010 Instruction Manual/English Buzzer Settings The Buzzer settings allow you to set whether the buzzer will Description sound for PASS/FAIL judgments. The buzzer time can also be set for the PASS/FAIL judgments. The buzzer settings are system-wide. Steps 1. Ensure the tester is in VIEW status. Save the Page 71 current test if necessary.
Page 117
IIT-2000/2010/5000/5010 Instruction Manual/English 5. Use the scroll wheel to select a parameter for the chosen menu item. Pass Sound ON (000.2s~999.9s), OFF Fail Sound ON (000.2s~999.9s), OFF EDIT/SAVE 6. Press EDIT/SAVE to save the settings and exit to the VIEW status.
Page 118
IIT-2000/2010/5000/5010 Instruction Manual/English VIEW status M A N U = * * * - 0 0 0 0 m A F R E Q = 0 H z 1 . 0 0 m A 0 100 A M P 0 0 . 1 S = 0 0 1 .
Page 119
IIT-2000/2010/5000/5010 Instruction Manual/English EDIT/SAVE 7. Press EDIT/SAVE to save the settings and exit to VIEW status. Ensure the baud rate settings or GPIB address matches the Note host machine. The ESC key can be pressed at any time to cancel and exit Note back to VIEW status.
Page 120
IIT-2000/2010/5000/5010 Instruction Manual/English number, mode or testing parameters. Only the Utility menu and any keys required for testing are not disabled. The Interlock function is a safety feature. The interlock function prevents a test from running, unless the interlock pins on the signal I/O port connector are shorted.
Page 121
INTERLOCK EDIT/SAVE 6. Press EDIT/SAVE to save the settings and exit to VIEW status. The Double Action setting is ignored when the IIT-2000/ Note 2010/5000/5010 is being controlled remotely using the USB, RS232 or GPIB interfaces. If a test is started with INTERLOCK ON, but the interlock...
Page 122
IIT-2000/2010/5000/5010 Instruction Manual/English Interlock open message M A N U = * * * - 0 0 0 0 m A F R E Q = 0 H z 1 . 0 0 m A I N T E R L O C K...
IIT-2000/2010/5000/5010 Instruction Manual/English XTERNAL CONTROL The External Control chapter covers the REMOTE terminal and the SIGNAL I/O port. External Control Overview ............122 Remote Terminal Overview .................. 122 Remote Controller Operation ................123 SIGNAL I/O Overview ................... 124 Using the SIGNAL I/O to Start/Stop Tests ............127 Using the Interlock Key ..................
IIT-2000/2010/5000/5010 Instruction Manual/English External Control Overview The External Control section describes the front panel REMOTE terminal connection and the rear panel SIGNAL I/O port. Remote Terminal Overview Overview The REMOTE terminal connector is a standard 5-pin DIN terminal suitable for a remote controller.
Description controllers with a START and STOP button. To use the REMOTE terminal, the IIT-2000/2010/5000/5010 must first be configured to accept a remote controller. Operating a remote controller is the same as operating the START and STOP buttons on the front panel.
IIT-2000/2010/5000/5010 Instruction Manual/English Even if the IIT-2000/2010/5000/5010 is configured to use the NOTE REMOTE CONNECT option, the STOP button on the front panel can still be used to stop a test. 4. To return the operation control to the front panel, Page 117 configure the Start Ctrl option to FRONT PANEL.
Page 127
IIT-2000/2010/5000/5010 Instruction Manual/English OUTPUT_FAIL Indicates that a test has failed OUTPUT_PASS 8 Indicates that a test has passed OUTPUT_COM 9 Common output line Interlock PIN 1 INTERLOCK1 connection PIN 2 INTERLOCK2 Input PIN 3 INPUT_COM Connection PIN 4 INPUT_START PIN 5 INPUT_STOP...
Page 128
IIT-2000/2010/5000/5010 Instruction Manual/English Input Stop and INPUT_STOP Input Start INPUT_START Timing 05/08/2015 Version No. 001...
INPUT_COM lines for a minimum of 1ms. 5. To stop the testing, temporarily short the INPUT_STOP and INPUT_COM line again. Even if the IIT-2000/2010/5000/5010 is configured to use the NOTE SIGNAL I/O interface, the STOP button on the front panel can still be used to stop a test.
IIT-2000/2010/5000/5010 Instruction Manual/English Using the Interlock Key When the INTERLOCK function is set to ON, tests are only Background allowed to start when both Interlock pins on the signal I/O port are shorted. Using the Interlock key will short the INTERLOCK1 and INTERLOCK2 pins on the signal I/O port.
IIT-2000/2010/5000/5010 Instruction Manual/English Interface Configuration USB Remote Interface Type A, host PC side Configuration connector Rear panel Type A IIT-5000 side connector CDC (communications device class) (VCP, USB Class Virtual Com Port) Panel operation 1. Connect the USB cable to the rear panel USB A port.
Page 134
IIT-2000/2010/5000/5010 Instruction Manual/English 2. Set the interface to RS232 from the Common Page 115 Utility menu. GPIB Remote Interface GPIB 0-30 Address Configuration GPIB Panel operation 1. Connect the GPIB cable to the rear panel GPIB port. 2. Set the interface to GPIB and set the GPIB Page 115 address from the Common Utility menu.
Page 135
*idn? This should return the Model number, Serial number, and Firmware version in the following format: IIT-2000, XXXXXXXXXXXX, V1.00 Model number : IIT-2000 Serial number :12 character serial number Firmware version : V1.00 ^j can be used as the terminal character when entering the queries/commands from a terminal application.
Page 136
IIT-2000/2010/5000/5010 Instruction Manual/English Display When the panel is being remotely controlled via the USB, RS232 or GPIB interfaces, RMT will be displayed on the screen. M A N U = * * * - 0 0 0 0 m A...
Page 137
IIT-2000/2010/5000/5010 Instruction Manual/English START automatic test, see pages 72 and 102, respectively. To put the tester back to RMT, simply issue another remote Note control command. 05/08/2015 Version No. 001...
IIT-2000/2010/5000/5010 Instruction Manual/English Command Syntax Partial compatibility IEEE488.2 Compatible Partial compatibility Standard SCPI, 1999 Command SCPI commands follow a tree-like structure, organized into Structure nodes. Each level of the command tree is a node. Each keyword in an SCPI command represents each node in the command tree.
Page 139
IIT-2000/2010/5000/5010 Instruction Manual/English Setting A single or compound command with/without a parameter Example MANU:STEP 1 Query A query is a simple or compound command followed by a question mark (?). A parameter (data) is returned. Example MANU:ACW:VOLTage? Command Commands and queries have two different forms, long and short.
Page 140
IIT-2000/2010/5000/5010 Instruction Manual/English MANU:STEP 100 1. Command header Command Format 2. Space 3. Parameter Parameters Type Description Example <Boolean> Boolean logic 0, 1 <NR1> integers 0, 1, 2, 3 <NR2> decimal 0.1, 3.14, 8.5 numbers <NR3> floating point 4.5e-1, 8.25e+1 <NRf>...
IIT-2000/2010/5000/5010 Instruction Manual/English SYSTem:LCD:BRIGhtness Query Description Sets the brightness of the LCD display from 1(dark) to 2(bright). Syntax SYSTem:LCD:BRIGhtness <NR1> Query Syntax SYSTem:LCD:BRIGhtness? Parameter/ <NR1> 1 (dark), 2 (bright) Return parameter Example SYST:LCD:BRIG 2 Sets the display brightness to bright.
IIT-2000/2010/5000/5010 Instruction Manual/English SYSTem:BUZZer:FSOUND Query Description Turns the buzzer sound on or off for a FAIL judgment. Syntax SYSTem:BUZZer:FSOUND{ON|OFF} Query Syntax SYSTem:BUZZer:FSOUND ? Parameter/ FAIL Sound on. Return FAIL Sound off. parameter Example SYST:BUZZ:FSOUND ON Turns the buzzer sound on for FAIL judgments.
IIT-2000/2010/5000/5010 Instruction Manual/English SYSTem:BUZZer:FTIMe Query Description Sets the FAIL Sound duration in seconds. Syntax SYSTem:BUZZer:FTIMe <NR2> Query Syntax SYSTem:BUZZer:FTIMe? Parameter/ <NR2> 0.2~999.9 Return parameter Example SYST:BUZZ:FTIM 1 Sets the buzzer to 1 second for a FAIL judgment. SYSTem:ERRor Query Description Returns any errors in the output buffer.
Page 149
0,No Error 20,Command Error 21,Volume Error 22,String Error 23,Query Error 24,Mode Error 25,Time Error 26,DC Over 50W (IIT-2000/2010), DC Over 100W (IIT- 5010/5000 27,GBV > 5.4V 30,Voltage Setting Error 31,Current Setting Error 32,Current HI SET Error 33,Current LO SET Error...
IIT-2000/2010/5000/5010 Instruction Manual/English 50, Scanner Box Not Found 51, HI Channel Setting Error 52, LO Channel Setting Error 60, Get Data = 0 (IIT-5010/5000 gets SWEEP data) Example SYST:ERR ? >0,No Error Returns “0,No Error” as the error message. SYSTem:GPIB:VERSion...
IIT-2000/2010/5000/5010 Instruction Manual/English Function Commands FUNCtion:TEST ....................149 MEASure<x> ......................150 MAIN:FUNCtion ....................151 FUNCtion:TEST Query Description Turns the currently selected test (output) on or off. When HOLD is displayed on the screen during AUTO tests, use the FUNCtion:TEST command to move on to the next step.
IIT-2000/2010/5000/5010 Instruction Manual/English Example FUNC:TEST ON Turns the output on. MEASure<x> Query Description Returns the test parameters & results of the tester in either MANU or AUTO mode. MANU mode: Returns the test parameters & results of a MANU test.
IIT-2000/2010/5000/5010 Instruction Manual/English Function ACW, DCW, IR, GB Judgment PASS, FAIL /Status VIEW Test voltage voltage+unit Test current current+unit /Test resistance resistance+unit Test time T=time+S /Ramp time R=time+S Example MEAS? (in MANU mode) >ACW,FAIL,0.024kV,0.013 mA ,R=000.1S Returns the test result of the current manual test.
Page 154
IIT-2000/2010/5000/5010 Instruction Manual/English Parameter/ MANU Puts the tester mode to MANU. Return AUTO Puts the tester mode to AUTO. parameter Example MAIN:FUNC MANU Sets the tester to MANU mode. 05/08/2015 Version No. 001...
IIT-2000/2010/5000/5010 Instruction Manual/English MANU:NAME Query Description Sets or returns the test name for the selected manual test. The test must be in MANU mode before this command can be used. Note only alphanumeric characters (A-Z, a-z, 0-9) and the “_”...
Sets or returns the Ramp Time for the test in seconds. Note: A “TIME ERR” will result if the Ramp Time + Test Time is ≥ 240 seconds when the HI SET limit is over 30mA (IIT-2000/2010) or over 80mA (IIT-5010/5000). This applies to the ACW function only.
ACW mode before this command can be used. Syntax MANU:ACW:CHISet <NR2> Query Syntax MANU:ACW:CHISet? Parameter/ <NR2> 0.001 ~ 042.0 (IIT-2000/2010) Return 0.001 ~ 110.0 (IIT-5010/5000) parameter Example MANU:ACW:CHIS 10.0 Sets the ACW HI SET current to 10 mA.
HI SET. LO SET value2 will not produce an error, but will return 0.05, not 0.053. Syntax MANU:ACW:CLOSet<NR2> Query Syntax MANU:ACW:CLOSet? Parameter/ <NR2> 0.000 ~ 041.9 (IIT-2000/2010) Return 0.000 ~ 109.9 (IIT-5010/5000) parameter Example MANU:ACW:CLOS 20.0 Sets the ACW LO SET current to 20 mA.
IIT-2000/2010/5000/5010 Instruction Manual/English 240 seconds when the HI SET limit is over 30mA (IIT-2000/2010) or over 80mA (IIT-5010/5000). This applies to the ACW function only. In special MANU mode, the TIMER can be turned off. Syntax MANU:ACW:TTIMe {<NR2>|OFF} Query Syntax...
The ACW reference value must use the same range as the HI SET value. Syntax MANU:ACW:REF <NR2> Query Syntax MANU:ACW:REF? Parameter/ <NR2> 0.000 ~ 041.9 (IIT-2000/2010) Return 0.000 ~ 109.9 (IIT-5010/5000) parameter Example MANU:ACW:REF 0.01 Sets the ACW reference to 0.01 mA.
DCW mode before this command can be used. Note: A “DC Over 50W” error will result if the DCW Voltage X HI SET value is > 50 watts (IIT-2000/2010). Note: A “DC Over 100W” error will result if the DCW Voltage X HI...
Note: A “DC Over 100W” error will result if the DCW Voltage X HI SET value is > 100 watts (IIT-5010/5000) Syntax MANU:DCW:CHISet <NR2> Query Syntax MANU:DCW:CHISet? Parameter/ <NR2> 0.001 ~ 011.0 (IIT-2000/2010) Return 0.001 ~ 021.0 (IIT-5010/5000) parameter 05/08/2015 Version No. 001...
HI SET. LO SET value2 will not produce an error, but will return 0.05, not 0.053. Syntax MANU:DCW:CLOSet<NR2> Query Syntax MANU:DCW:CLOSet? Parameter/ <NR2> 0.000 ~ 010.9 (IIT-2000/2010) Return 0.000 ~ 020.9 (IIT-5010/5000) parameter 05/08/2015 Version No. 001...
IIT-2000/2010/5000/5010 Instruction Manual/English Example MANU:DCW:CLOS 2.00 Sets the DCW LO SET current to 2mA. MANU:DCW:TTIMe Query Description Sets or returns the DCW test time in seconds. The test must first be in DCW mode before this command can be used.
IIT-2000/2010/5000/5010 Instruction Manual/English Syntax MANU:DCW:REF <NR2> Query Syntax MANU:DCW:REF? Parameter/ <NR2> 0.000 ~ 010.9 (IIT-2000/2010) Return 0.000 ~ 020.9 (IIT-5010/5000) parameter Example MANU:DCW:REF 0.01 Sets the DCW reference to 0.01 mA. MANU:DCW:ARCCurrent Query Description Sets or returns the DCW ARC current value in mA. ARC must be enabled to set the ARC current.
IIT-2000/2010/5000/5010 Instruction Manual/English MANU:IR:VOLTage Query Description Sets or returns the IR voltage in kV. The test must first be in IR mode before this command can be used. Syntax MANU:IR:VOLTage <NR2> Query Syntax MANU:IR:VOLTage? Parameter/ <NR2> 0.05 ~ 1 (0.05kV to 1kV: steps of .05) Return *IIT-5010 also includes a 0.125kV point.
IIT-2000/2010/5000/5010 Instruction Manual/English MANU:IR:REF Query GΩ Sets or returns the IR reference value in MΩ (IIT-2010) or Description (IIT 5010). The test must first be in IR mode before this command can be used. The reference value must be lower than the HI SET value.
IIT-2000/2010/5000/5010 Instruction Manual/English MANU:GB:CURRent Query Description Sets or returns the GB current in A. The test must first be in GB mode before this command can be used. Syntax MANU:GB:CURRent <NR2> Query Syntax MANU:GB:CURRent? Parameter/ <NR2> 3.00~33.00 (IIT-2010) Return 3.00~33.00 (IIT-5010)
IIT-2000/2010/5000/5010 Instruction Manual/English If the (GB current x HI SET resistance) > 5.4V, then an error will Note be generated (“GBV > 5.4V”). MANU:GB:RLOSet Query Sets or returns the GB LO SET resistance value in mΩ. The LO Description SET value must be less than the HI SET value. The test must first be in GB mode before this command can be used.
IIT-2000/2010/5000/5010 Instruction Manual/English Parameter/ <NR2> 0.5 ~ 999.9 seconds Return parameter Example MANU:GB:TTIM 1 Sets the GB test time to 1 second. MANU:GB:FREQuency Query Description Sets or returns the GB test frequency in Hz. The test must first be in GB mode before this command can be used.
IIT-2000/2010/5000/5010 Instruction Manual/English Parameter/ <NR2> 0.000 ~ 649.9 Return parameter Example MANU:GB:REF 100 Sets the GB reference to 100 mΩ. MANU:GB:ZEROCHECK Query Description Performs the zero check function. The test must first be in GB mode and in the Ready Status before this command can be used.
IIT-2000/2010/5000/5010 Instruction Manual/English Syntax MANU:UTILity:ARCMode {OFF|ON_CONT| ON_STOP} MANU:UTILity:ARCMode? Query Syntax Parameter/ Turns ARC mode off. Return ON_CONT Sets ARC mode to ON and CONTINUE. parameter ON_STOP Sets ARC mode to ON and STOP. Example MANU:UTIL:ARCM OFF Turns ARC mode OFF.
IIT-2000/2010/5000/5010 Instruction Manual/English Syntax MANU:UTILity:FAILmode {CONT|HOLD|STOP} Query Syntax MANU:UTILity:FAILmode? Parameter/ CONT Sets/returns the fail mode as continue. Return HOLD Sets/returns the fail mode as hold. parameter STOP Sets/returns the fail mode as stop. Example MANU:UTIL:FAIL CONT Sets the fail mode to CONT (continue).
IIT-2000/2010/5000/5010 Instruction Manual/English MANU:UTILity:GROUNDMODE Query Description Sets or returns the Grounding mode of the current test. The Ground Mode setting cannot be turned on with the IR and GB function. Syntax MANU:UTILity:GROUNDMODE {ON|OFF} Query Syntax MANU:UTILity:GROUNDMODE? Parameter/ Turns ground mode off.
Page 180
IIT-2000/2010/5000/5010 Instruction Manual/English <string> Returns a string in the following format: Test function, test voltage, HI SET value, LO SET value, Ramp time, test time. Example MANU1:EDIT:SHOW ? > ACW,0.100kV,H=01.00mA,L=00.00mA,R=000.1S, >T=001.0S. Returns the test parameters of manual test number 1.
IIT-2000/2010/5000/5010 Instruction Manual/English Sweep Commands SWEEP:DATA:STATus ..................179 SWEEP<X>:DATA:SHOW ..................180 SWEEP:GRAPh:SHOW ..................181 SWEEP :GRAPh:LINE ..................182 SWEEP:STARt:TIME .................... 183 SWEEP:DATA:STATus Query Description Returns the sweep mode, the voltage and current settings and the number data points that are used in the last sweep. There can be a maximum of 190 data points, depending on the testing time.
IIT-2000/2010/5000/5010 Instruction Manual/English SWEEP<X>:DATA:SHOW Query Description Returns the data associated with a sweep graph. Data can be returned in one of two ways; either all the data can be returned or only the data at a particular point in time.
IIT-2000/2010/5000/5010 Instruction Manual/English Query Syntax SWEEP<X>:DATA:SHOW? Parameter <X> <NR1> 1~190 (single data point) <X> <NR1> 0 (all data points) Single Data SWEEP10:DATA:SHOW? Point Example > 010,0.106,00.00,0001.0, CR+LF Returns the data at point 10, which is at the 1 second time for the sweep test.
IIT-2000/2010/5000/5010 Instruction Manual/English Parameter/ Turn the sweep graph on. Return Turn the sweep graph off. parameter Example SWEEP:GRAP:SHOW ON Displays the sweep graph on the LCD display. SWEEP :GRAPh:LINE Query Description Sets or returns which lines are shown on the sweep graph.
IIT-2000/2010/5000/5010 Instruction Manual/English Example SWEEP:GRAP:LINE 3 Turns all the graph lines on. SWEEP:STARt:TIME Query Description Sets or returns the start time (STA.t) of the sweep graph in milliseconds. This setting will also set what the time will be for the first point for the sweep data that is returned in the SWEEP:DATA:SHOW query.
IIT-2000/2010/5000/5010 Instruction Manual/English Example AUTO:STEP 100 Sets the current AUTO number to 100. AUTO<x>:PAGE:SHOW Query Description Returns the Page View of the selected automatic test in the following format: step1:MANU number, step2: MANU number, step3….etc. Query Syntax AUTO<x>:PAGE:SHOW? Parameter/ <x>...
IIT-2000/2010/5000/5010 Instruction Manual/English <Value2 <NR1> 1~16 (destination step) > Example AUTO:PAGE:MOVE 1, 4 Moves the contents of step 1 to the step 4. A U T O = 0 0 1 - 0 1 M A N U _ N A C W = 0 .
IIT-2000/2010/5000/5010 Instruction Manual/English AUTO:PAGE:SKIP Query Description Skips the selected step when an AUTO test is run. This is shown as an asterisk (*) when in the PAGE view. Syntax AUTO:PAGE:SKIP <NR1>,{ON|OFF} Parameter/ <NR1> 1~16 (step no.#) Skip the selected step.
IIT-2000/2010/5000/5010 Instruction Manual/English AUTO:NAME Query Description Sets or returns the AUTO name for the selected automatic test. The test must be in AUTO mode before this command can be used. Note only alphanumeric characters (A-Z, a-z, 0-9) and the “_”...
IIT-2000/2010/5000/5010 Instruction Manual/English Example AUTO:EDIT:ADD 7 Adds MANU-007 to the current AUTO number. I.e., A U T O = 0 0 5 - 0 0 M A N U _ N A C W = 0 . 0 0 k 1 .
IIT-2000/2010/5000/5010 Instruction Manual/English *SRE Query Description AUTO MODE only. Use this command to get measurement step number at the current point in time during AUTO MODE testing. Example: User send command “*SRE” to IIT-20X0/50X0 during AUTO mode Query Syntax *SRE? Return <NR1>...
Query Syntax *IDN? Returns the instrument identification as a string in the Return <string> following format: parameter IIT-2000, XXXXXXXXXXXX, V1.00 Model number : IIT-2000 Serial number :12 character serial number Firmware version : V1.00 05/08/2015 Version No. 001...
Page 194
IIT-2000/2010/5000/5010 Instruction Manual/English Remote Commands *RMTOFF ......................192 *RMTOFF Description This command can be used to terminate a remote session. When this command is used “RMT” will no longer be displayed on the front panel, indicating that remote mode has been terminated.
Page 195
IIT-2000/2010/5000/5010 Instruction Manual/English interlock signal I/O pins are not shorted (either with the included interlock key or manually). This special function is analogous to the “INTERLOCK OPEN”message that is displayed on the front panel under the same conditions (page 119).
IIT-2000/2010/5000/5010 Instruction Manual/English • The tester will not turn on. • The panel keys are not working. • When I press the START button the tester will not start testing? • The accuracy does not match the specification. The tester will not turn on.
Page 198
IIT-2000/2010/5000/5010 Instruction Manual/English When I press the START button the tester will not start testing? The tester must first be in the READY status before a test can be started. Ensure the tester displays READY before pressing the START button, page 72 (manual test), 102(automatic test).
IIT-2000/2010/5000/5010 Instruction Manual/English PPENDIX Fuse Replacement POWER Steps 1. Turn the instrument off. 2. Remove the power cord. 3. Remove the fuse socket using a flat screwdriver. 4. Replace the fuse in the fuse holder. 05/08/2015 Version No. 001...
IIT-2000/2010/5000/5010 Instruction Manual/English 5. Ensure the correct line voltage is lined up with the arrow on the fuse holder. Insert the fuse socket. The fuse for the IIT-2000/2010 and the IIT-5010/5000 have Rating different ratings: IIT-2000/2010: 100V/120V T5A 250V 220V/230V T2.5A 250V...
Page 201
IIT-2000/2010/5000/5010 Instruction Manual/English Error Messages Description TIME ERR For ACW tests. IIT-2000/2010: TIME ERR is displayed when HI SET ≥ 30.00mA~40.00mA and if the RAMP time and the TEST TIME setting is > 240 seconds. IIT-5010/5000: TIME ERR is displayed when HI SET ≥ 80.00mA~100.0mA and if the RAMP time and the TEST TIME setting is >...
Page 202
IIT-2000/2010/5000/5010 Instruction Manual/English For IR tests. The voltage is too high or resistance=0Ω. R ERR Check to see whether the DUT or test lead is shorting. For GB tests. The resistance is too high. I<SET For GB tests. Current too low. Indicates that the SOURCE L or SOURCE H test lead is open or poorly connected.
IIT-2000/2010/5000/5010 Instruction Manual/English IIT-2000/2010/5000/5010 Specifications The specifications apply when the IIT-2000/2010/5000/ 5010 is powered on for at least 30 minutes at 15˚C~35˚C. Specifications Environment Range Temperature Humidity 15˚C ~ 35˚C ≤70% (No condensation) Warranty 0˚C ~ 40˚C ≤70% (No condensation) Operation -10˚C ~ 70˚C...
Page 204
IIT-2000/2010/5000/5010 Instruction Manual/English 1% +5V Voltage Regulation [Maximum rated load → no load] (1% of reading+ 5V) Voltmeter Accuracy Current Measurement 0.001mA~040.0mA [IIT-2000/2010] Range 0.001mA~100.0mA [IIT-5000/5010] Current Best Resolution IIT-2000/2010: 0.001mA(0.001mA~0.999mA) 0.01mA(01.00mA~09.99mA) 0.1mA(010.0~040.0mA) IIT-5000/5010: 0.001mA(0.001mA~1.100mA) 0.01mA(01.11mA~11.00mA) 0.1mA(011.1~100.0mA) Current Measurement...
Page 205
(1% of setting +5V) with no load Output Voltage Accuracy Maximum Rated Load 50W (5kV/10mA)[IIT-2000/2010] 100W (5kV/20mA)[IIT-5010/5000] Maximum Rated Current 10mA [IIT-2000/2010, 20mA [IIT-5010/5000] 0.001mA ~ 2mA (0.100kV≤V≤0.5kV) 0.001mA ~ 10mA (0.5kV<V≤6kV)[IIT-2000/2010] 0.001mA ~ 20mA (0.5kV<V≤6kV)[IIT-5000/5010] (1% of reading+ 5V) Voltmeter Accuracy ...
Page 206
IIT-2000/2010/5000/5010 Instruction Manual/English Current Best Resolution IIT-2000/2010: 0.001mA(0.001mA~0.999mA) 0.01mA(01.00mA~09.99mA) 0.1mA(010.0mA) IIT-5010/5000: 0.001mA(0.001mA~1.100mA) 0.01mA(01.11mA~11.00mA) 0.1mA(011.0mA~020.0mA) Current Measurement IIT-2000/2010: Accuracy ± (1.5% of rdg + 30 counts) when HI SET <1.00mA (1.5% of rdg + 3 counts) when HI SET ≥1.00mA IIT-5010/5000: ±...
Page 207
IIT-2000/2010/5000/5010 Instruction Manual/English Rise-time Control Function RAMP (Ramp Time) 0.1~999.9S TIMER (Test Time) , 0.5S~999.9S ON/OFF The timer can only be turned off under special MANU mode (MANU=***-000). Insulation Resistance Test Output Voltage 50V~1000V *IIT-5010 also includes a 125V test point.
Page 208
IIT-2000/2010/5000/5010 Instruction Manual/English Rise-time Control Function RAMP (Ramp Time) 0.1~999.9S TIMER (Test Time) 1S~999.9S Ground Bond Test Output Current Range 03.00A~30.00A (IIT-2010) 03.00A~32.00A (IIT-5010) (1% of setting +0.2A) when 3A≤I≤8A Output Current Accuracy (1% of setting +0.05A) when 8A<I≤30A (IIT-2010) ...
Page 209
IIT-2000/2010/5000/5010 Instruction Manual/English IIT-5010: Test Voltage Max. 6V(AC)open-circuit Ohmmeter Measurement 0.1m Resolution Windows Comparator Method TIMER (Test Time) 0.5S~999.9S Interface REMOTE (Remote terminal) Yes SIGNAL IO RS232 USB (Device) GPIB Yes (OPTION) General DISPLAY 240 x 64 dot matrix LED back light LCD...
Page 210
Power cord x1, Quick Start Guide x1 User Manual x1 (CD) GHT-114x1 for IIT-2000/5000 GHT-114x1, GTL-115x1 for IIT-2010/5010 DIMENSIONS & WEIGHT IIT-2000/2010: Approx. 330(W) x 148(H) x 452(D) mm (Max.), 19kg(Max) IIT-5010: Approx. 330(W) x 148(H) x 587(D) mm (Max.), 27kg(Max) IIT-5000: Approx. 330(W) x 148(H)
Page 211
IIT-2000/2010/5000/5010 Instruction Manual/English 80mA≤I≤100m At least as long Maximum 240 seconds as the output time 0.001mA≤I<80 Not necessary Continuous output possible 0.001mA≤I≤20 Not necessary Continuous output possible 15A<I≤32A At least as long 999.9 (IIT-5010) as the output time 3A≤I≤15A Not necessary 999.9 NOTE: Output Time = Ramp Time + Test Time.
IIT-2000/2010/5000/5010 Instruction Manual/English IIT-5000 Dimensions 425.9 PASS FAIL READY TEST AC / DC Withstanding Voltage / Tester Insulation Resistance CAUTION 5.0 kVAC MAX. HIGH VOLTAGE 6.0 kVDC MAX. PAGE START STOP RETURN REMOTE POWER MANU/AUTO EDIT/SAVE UTILITY 482.0 322.0 05/08/2015 Version No. 001...
Page 216
Type of Product: Electrical Safety Tester Model Number: IIT-2000, IIT-2010 are herewith confirmed to comply with the requirements set out in the Council Directive on the Approximation of the Law of Member States relating to Electromagnetic Compatibility (2014/30/EU) and Low Voltage Directive (2014/35/EU).
IIT-2000/2010/5000/5010 Instruction Manual/English Declaration of Conformity declare that the below mentioned product Type of Product: Electrical Safety Tester Model Number: IIT-5000, IIT-5010 are herewith confirmed to comply with the requirements set out in the Council Directive on the Approximation of the Law of Member States relating to Electromagnetic Compatibility (2014/30/EU) and Low Voltage Directive (2014/35/EU).
IIT-2000/2010/5000/5010 Instruction Manual/English NDEX overview ............122 Accessories ..........12 remote operation ........123 Automatic test remote terminal ........... 122 add test ............95 signal I/O operation ........127 edit settings ........... 94 signal I/O overview ........124 load..............93 FAQ ............
Page 219
IIT-2000/2010/5000/5010 Instruction Manual/English saving ............71 Command syntax ........136 special mode ..........86 function check ..........133 interface configuration ....... 130 sweep ..............86 sweep graph ..........90 Service operation test filename..........56 about disassembly ......... 4 test frequency ..........48 contact ............
Page 220
IIT-2000/2010/5000/5010 Instruction Manual/English Limited Warranty This meter is warranted to the original purchaser against defects in material and workmanship for 3 years from the date of purchase. During this warranty period, RS Components will, at its option, replace or repair the defective unit, subject to verification of the defect or malfunction.
Page 221
IIT-2000/2010/5000/5010 Instruction Manual/English Africa RS Components SA P.O. Box 12182, Vorna Valley,1686 20 Indianapolis Street, Kyalami Business Park, Kyalami, Midrand, South Africa Asia RS Components Pte Ltd. 21 Tech Park Crescent Singapore 638040 China RS Components Ltd. Suite 23 A-C...