American Standard AccuLink Platinum 850 User Manual
American Standard AccuLink Platinum 850 User Manual

American Standard AccuLink Platinum 850 User Manual

Smart control
Hide thumbs Also See for AccuLink Platinum 850:

Advertisement

Quick Links

AccuLink™ American Standard
Platinum 850 Smart Control User Guide
The Platinum 850 is an easy-
to-use, programmable control
with a color touch-screen.
When connected with
®
American Standard
Home
you can control your home's
heating and cooling system
and up to 230 separate
Z-Wave™ devices from a
smartphone, PC or tablet from
virtually anywhere.
This guide will help you
con gure and connect your
Platinum 850 Smart Control
quickly and easily.
Start using your
new Platinum 850
now! See "Start
Here!" on page 3.
012-5061-06C-EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AccuLink Platinum 850 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for American Standard AccuLink Platinum 850

  • Page 1 AccuLink™ American Standard Platinum 850 Smart Control User Guide The Platinum 850 is an easy- to-use, programmable control with a color touch-screen. When connected with ® American Standard Home you can control your home’s heating and cooling system and up to 230 separate Z-Wave™...
  • Page 2: Table Of Contents

    Congratulations! Thank you for choosing the American Standard http://www.asairhome.com Contents Platinum 850 Smart Control. The intuitive For tutorials search: Platinum 850. interface and powerful features incorporated User Setup Wizard ........... 3 into the compact design of the color touch- Navigating the Control ......... 4 American Standard Home allows you to: Temperature Control Panel .........
  • Page 3: User Setup Wizard

    To complete the Setup Wizard and connect the • Your Platinum 850 control comes equipped Schedule Settings Platinum 850 to American Standard Home, you with remote access and other features from • Set the Platinum 850 scheduling feature to need: American Standard Home.
  • Page 4: Navigating The Control

    Default Home Screen can be customized with several widgets. To learn more about this feature see the Date and Time Notifications and System Alerts section in this user guide about customization. American Standard Home and Network Status Increase set point...
  • Page 5 Home Screen View Homeowners may toggle between Home Screen Options by selecting: Home Screen > Menu > Settings > Screen > Home View Options. Select Simple View or Classic View. NOTE: Simple View is the default view. Simple View Classic View 012-5061-06C-EN page 5...
  • Page 6 Home Screen - Classic View Home Screen can be customized with several widgets. To learn more about this feature see the section in this user guide about customization. Date and Time Notifications and System Alerts American Standard Home and Network Status 1-Touch presets (Off/Home/Away/...
  • Page 7: Temperature Control Panel

    Temperature Control Panel The Temperature Control Panel is where target Available when Available when temperatures are manually set and adjusted. Scheduling is Enabled Scheduling is Disabled Activate 1-Touch Presets The panel is shown on the Classic View Home Cooling Set Point Disable Schedule (select to change) Screen only.
  • Page 8: Home Screen - Simple View

    Home Screen - Simple View Optionally, up to 2 widgets may be chosen to appear on your home screen. They can be selected by navigating to Menu >  Settings > Screen > Screen Layout When scheduling is enabled, the Preset button is disabled and a Permanent Hold button is displayed.
  • Page 9: Home Screen Customization

    Home Screen Customization Homeowners may customize the Home Screen by selecting: Menu > Settings > Screen > Screen Layout Choose up to two widgets (or apps) to show up on the Home Screen. Make selection and select Apply. 012-5061-06C-EN page 9...
  • Page 10: Menu Screen

    Menu Screen Navigate to Menu Screen by selecting: Home Screen > Menu Edit your schedule (when scheduling Weather, 5-Day Forecast, System Information: Alerts, is enabled) or edit 1-Touch Presets Radar and Weather Demand Response, (when scheduling is disabled) Alerts. Notifications, and About Enable/Disable Scheduling at Menu>Schedules &...
  • Page 11: Settings Screen

    Navigate to Settings Screen by pressing: Home Screen > Menu > Settings Manually set the Date, Time and Time User Setup Wizard Modify screen brightness, Zone. No need to update when backlight timer, screensaver, connected to American Standard Home. and color theme Temperature scale, Deadband, Calibration* and Displayed Outdoor...
  • Page 12: Scheduling

    Schedule Screen Navigate to Scheduling Screen by selecting: Home Screen > Menu > Schedules & Presets > Custom Schedule The current day or group Press in the red or blue area, then adjust the Set Point of days is highlighted using the up and down arrows Change start or stop...
  • Page 13 Grouping Screen Navigate to Grouping Screen by selecting: Home Screen > Menu > Schedules & Presets > Custom Schedule > Grouping Then select the days to be grouped or removed from Select Grouping to use the same set points and times the group.
  • Page 14: Changing Periods

    To change Periods select: Home Screen > Menu > Schedules & Presets > Changing Periods Custom Schedule > Select Schedule time Adjust Start and Press in the red or blue area, then adjust End Times the Set Point using the up Changing Period Start or End Times and down arrows 1.
  • Page 15: Adding Periods

    Adding Periods Navigate to Add Period by selecting: Home Screen > Menu > Schedules & Presets > Custom Schedule > Add Period The Platinum 850 Smart Control is capable of 2. Select the green circle where you would like 5. Select NEXT. adjusting the temperature settings throughout to insert a Period.
  • Page 16: Deleting Periods

    Deleting Periods Navigate to Delete Periods by selecting: Home Screen > Menu > Schedules & Presets > Custom Schedule > Delete Period Deleting Periods Select the trash can to mark a period for deletion 1. From the Schedule Screen select DELETE PERIOD, the Delete Periods Screen is Delete Periods displayed.
  • Page 17: Overriding Schedules

    Overriding Schedules NOTE: These functions require Scheduling to 6. Press in the STATUS AREA again to toggle Use the UP and DOWN Arrows to adjust the be enabled. To enable Scheduling, go to HOME to the Time setting. The Time will appear in Set Point to the desired temperature.
  • Page 18: Con Guring 1-Touch Presets

    Con guring 1-Touch Presets Navigate to Con guring 1-Touch Presets by selecting: Home Screen > Menu > Schedules & Presets > 1-Touch Presets 1-Touch Presets provide predetermined Heating Cooling Set Point and Cooling Set Points for Home, Away and Sleep (select to change) time periods.
  • Page 19 Con guring 1-Touch Presets 1-Touch Presets provide predetermined Heating Con guring 1-Touch Presets Use the UP and DOWN Arrows to adjust the and Cooling Set Points for Home, Away and Sleep Set Point to the desired temperature. 1. To change the Cooling Set Point, select the time periods.
  • Page 20: Setting Access Restrictions

    Setting Access Restrictions To select access restrictions select: Home Screen > Menu > Settings > Screen > Access Restrictions page 20 850 User Guide...
  • Page 21: American Standard Home

    American Standard Home When enrolled to an American Standard Home account, the Platinum 850 is a Z-Wave Plus™ security-enabled device that can serve as a central hub for an entire network of home automation devices from di erent manufacturers and product categories, including all non-battery powered devices that will act as repeaters on your network.
  • Page 22: Network Setup

    Network Setup There are several ways to connect the Platinum 850 Control to a local network: Option 2. WPS for Wi-Fi connection Option 1. Wi-Fi connection Wi-Fi Step 1. Navigate Home > Menu > Settings > Network > Connect WPS Step 1. Press the WPS button on your router, then return to your Platinum to WiFI Network.
  • Page 23 Hidden WiFi Step 2. Enter the name of the network you would like to connect will recognize an Ethernet connection. If an Ethernet cable is to then select Next. connected the User Wizard will skip the Wireless setup screens and display the American Standard Home registration screen next. 012-5061-06C-EN page 23...
  • Page 24: American Standard Home Registration

    Step 1. Go to www.asairhome.com or use your mobile app to setup an American Standard Home account. Download the AS Air Home mobile app from the Google Play™ Store or App Store ®...
  • Page 25 American Standard Home Registration Step 7. Return to the Platinum 850 control and Step 9. Read the License Agreement, then ACCEPT or select NEXT. DECLINE. Step 6. The mobile app will generate a Pin Code. Record the Pin Code. Step 8. Enter the Pin Code and select NEXT.
  • Page 26: Adding/Removing Z-Wave Devices

    SMART HOME. Your Platinum 850 is designed to integrate 2. Select ADD DEVICE and follow the device 1. From the HOME Screen, select MENU, then seamlessly with your American Standard Home manufacturer’s instructions for setting the select SMART HOME. account.
  • Page 27: Adding Z-Wave Devices (Via Mobile App)

    Adding Z-Wave Devices (via mobile app) Alternatively, your Platinum 850 allows you to add 4. Select Z-Wave Device. Z-Wave devices using the AS Air Home app on your mobile device. Adding Z-Wave Devices 1. Start the mobile app. 2. Select the menu button in the top left corner. 3.
  • Page 28: Advanced Z-Wave Settings

    This function is not allowed if your bridge is a primary controller with included Z-Wave devices. Unregister Removes the bridge from American Standard Home. All remote control features will be disabled. Factory Reset Resets all Z-Wave information and removes all devices from the bridge.
  • Page 29 Noti cation Terminology Other Information The following terms may be used interchangeably by other devices, This device ignores Basic Set/Get manufacturers, and American Standard Home. commands. Add, include, inclusion, enroll, connect Basic Command Class: This device controls other devices with OFF (0x00) and ON (0xFF) as a...
  • Page 30: Other Features

    The Platinum 850 Control is equipped with and select Disabled and select Apply. Smart Optimization. By executing a series of American Standard Home account, software blower tests, Smart Optimization will customize updates will occur automatically and do not To enable Smart Optimization, navigate to the Platinum 850 Control to each unique require user intervention.
  • Page 31: Notices

    Notices FCC Notice instructions, may cause harmful interference IC NOTICE to radio communications. However, there is no FCC ID: XVR-CONT8505 IC ID: 6178D-CONT8505 guarantee that interference will not occur in a INFORMATION TO USER This device complies with Industry Canada particular installation.
  • Page 32 About American Standard Heating and Air Conditioning American Standard has been creating comfortable and affordable living environments for more than a century. For more information, please visit www.americanstandardair.com. The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are com- mitted to using environmentally conscious print practices.

Table of Contents