Testing the 3-Way Valve
The valve returns to "home" at the end of every
freezer defrost cycle and whenever the refrig-
erator is reconnected to power.
To test the valve, disconnect the refrigerator
from power for at least 10 seconds, place a fi
nger on top of the valve and reconnect power.
The main control overdrives the valve to the
"home" position.
You should be able to feel the valve move as it
returns to the home position .
If movement is present, the main board and
valve coil are operating correctly.
Replacing the 3-Way Valve
Parts Needed:
• 3-Way Valve (part # WR57X10053)
• Thermal Paste (part # WX5X8927)
• Drier Assembly (part # WR86X93)
• Process valve (part # WJ56X61)
When replacing a 3-way valve, note the black
mark on the freezer outlet tube. Make certain to
mark the freezer capillary by placing a piece of
tape on the capillary, 6-8 inches from the valve.
This will aid in installing the capillaries in the
correct outlet tubes.
INLET
FRESH FOOD
– 29 –
Black Mark
OUTLET
FREEZER
OUTLET