GE Arctica G LINE PHG25PGT Series Technician Manual page 28

Side-by-side dual evaporator refrigerators with electronic touch controls

Advertisement

3-Way Valve Body
• The valve body contains a cam, rotor
and magnet.
• The rotor and cam are grooved to
rotate with the magnet.
• The entire valve body has refrigerant fl
owing through it when the compressor
is operating.
• Use care not to damage the top of the
valve body when installing the coil on
the valve.
• A locating pin is used to correctly align
the valve body in the valve coil.
• Failure to fully seat the valve in the coil
or to align it correctly with the pin can
cause the system to stop cooling.
Valve Body
Note: The 3-way valve comes only as a com-
plete assembly. Exploded view is for reference
only.
Valve Rotation
• The pulses of the valve coil cause the magnet
to rotate inside the valve body.
• As the magnet rotates, it moves the cam at
the bottom of the valve.
Rotor
Cam
Magnet
The cam opens or covers the ports to the
capillary tubes.
– 28 –
Magnet
Stop Point
(Home Position)
CAPILLARY
TUBE
PORTS